Effect of incident angle on ultrasonic transmission in steam flow for use with clamp-on ultrasonic flowmeter

被引:4
|
作者
Murakawa, Hideki [1 ]
Ichimura, Shuhei [1 ]
Shimada, Masaki [1 ]
Sugimoto, Katsumi [1 ]
Asano, Hitoshi [1 ]
Umezawa, Shuichi [2 ]
Sugita, Katsuhiko [2 ]
机构
[1] Kobe Univ, Grad Sch Engn, Nada Ku, 1-1 Rokkodai, Kobe, Hyogo 6578501, Japan
[2] Tokyo Elect Power Co Holdings Inc, Tsurumi Ku, 4-1 Egasaki, Yokohama, Kanagawa 2308510, Japan
来源
MECHANICAL ENGINEERING JOURNAL | 2020年 / 7卷 / 04期
关键词
Steam flow rate; Clamp-on; Ultrasonic flowmeter; Time-of-flight; Incident angle; Lamb wave;
D O I
10.1299/mej.20-00131
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Energy management in industrial plants requires measurements of the steam flow rates at each usage location. A clamp-on ultrasonic flowmeter can be used to effectively measure the steam flow rates in existing pipes. An ultrasonic flowmeter is used to calculate the transit time of ultrasonic signals between the downstream and upstream sensors, which is affected by the line-averaged velocity along the ultrasonic beam. The intensity of the transmitted ultrasonic signal is crucial for measuring the steam flow rate using the clamp-on ultrasonic flowmeter. The authors focused on the effects of the ultrasonic incident angle on the transmitted ultrasonic signal intensity in steam flow. Ultrasonic transmission experiments were carried out on three pipes (SGP 25A, SGP 50A and SGP 80A) filled with stationary nitrogen, and the transit time in steam flow was measured on SGP 80A pipe by changing the ultrasonic incident angle. The pipes are made of carbon steel and generally used for the steam flow. The results indicate that the appropriate incident angle that allowed the maximum transmitted signal intensity differed depending on the thickness of the pipe wall. Furthermore, a good agreement with the critical angles of the zero-order of symmetric mode in Lamb waves was noted. Thus, the propagated ultrasonic waves can be considered Lamb waves, which increase signal intensity. The transmitted signal intensity decreases because of the turbulent dissipation as the steam velocity increases. Appropriately setting the incident angle depending on the wall thickness, particularly for higher steam flow rates, is essential for evaluating the transit time difference between upstream and downstream transducers.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Clamp-on ultrasonic flowmeter for gases
    不详
    HYDROCARBON PROCESSING, 2001, 80 (10): : 30 - 30
  • [2] APPLICATION OF CLAMP-ON ULTRASONIC FLOWMETER FOR INDUSTRIAL FLOW MEASUREMENTS
    SZEBESZCZYK, JM
    FLOW MEASUREMENT AND INSTRUMENTATION, 1994, 5 (02) : 127 - 131
  • [3] Versatile clamp-on Doppler ultrasonic flowmeter
    不详
    HYDROCARBON PROCESSING, 2006, 85 (03): : 26 - 26
  • [4] Measurement of steam flow rates using a clamp-on ultrasonic flowmeter with various wetness fractions
    Murakawa, Hideki
    Ichimura, Shuhei
    Sugimoto, Katsumi
    Asano, Hitoshi
    Umezawa, Shuichi
    Taira, Hirotoshi
    Ibi, Masayuki
    Akahane, Hajime
    FLOW MEASUREMENT AND INSTRUMENTATION, 2021, 80
  • [5] Easy-setup clamp-on ultrasonic flowmeter
    Terao, Minako
    Tanaka, Hiroaki
    Tanaka, Yoshiaki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2014, 53 (07)
  • [6] HIGH-TEMPERATURE CLAMP-ON ULTRASONIC FLOWMETER
    NGUYEN, TH
    LYNNWORTH, LC
    RUNDE, HA
    MERILLO, M
    IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1983, 30 (03): : 214 - 214
  • [7] Clamp-on ultrasonic flowmeter data interface to SCADA host
    Douglass, SA
    ENTELEC '96, TECHNICAL PAPERS: TO EDUCATE AND INFORM, 1996, : 1 - 3
  • [8] Ultrasonic Transducer Positioning System for Clamp-on Flowmeter Applications
    Bailleu, Anett
    2016 IEEE SENSORS APPLICATIONS SYMPOSIUM (SAS 2016) PROCEEDINGS, 2016, : 122 - 127
  • [9] APPLICATION OF A PORTABLE CLAMP-ON ULTRASONIC FLOWMETER IN THE WATER INDUSTRY
    CASCETTA, F
    FLOW MEASUREMENT AND INSTRUMENTATION, 1994, 5 (03) : 191 - 194
  • [10] Feasibility Study on Clamp-on Ultrasonic Flowmeter Based on EMAT
    Ji, Bonggyu
    Park, Jae-Ha
    Cho, Seung Hyun
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2018, 38 (05) : 316 - 321