Estimation of the radiation exposure of a chest pain protocol with ECG-gating in dual-source computed tomography

被引:36
|
作者
Ketelsen, Dominik [1 ]
Luetkhoff, Marie H. [1 ]
Thomas, Christoph [1 ]
Werner, Matthias [1 ]
Buchgeister, Markus [2 ]
Tsiflikas, Ilias [1 ]
Reimann, Anja [1 ]
Burgstahler, Christof [3 ]
Kopp, Andreas F. [1 ]
Claussen, Claus D. [1 ]
Heuschmid, Martin [1 ]
机构
[1] Univ Tubingen, Dept Diagnost & Intervent Radiol, Univ Tubingen Hosp, D-72076 Tubingen, Germany
[2] Univ Tubingen Hosp, Dept Radiotherapy & Radiooncol, Tubingen, Germany
[3] Univ Tubingen Hosp, Dept Cardiol, Tubingen, Germany
关键词
Dual-source computed tomography; Radiation exposure; Effective dose; Chest pain; ACUTE CORONARY SYNDROMES; TUBE-CURRENT MODULATION; MULTIDETECTOR ROW CT; EMERGENCY-ROOM; MULTISLICE CT; ANGIOGRAPHY; PATIENT; HISTORY; NOISE;
D O I
10.1007/s00330-008-1109-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to evaluate radiation exposure of a chest pain protocol with ECG-gated dual-source computed tomography (DSCT). An Alderson Rando phantom equipped with thermoluminescent dosimeters was used for dose measurements. Exposure was performed on a dual-source computed tomography system with a standard protocol for chest pain evaluation (120 kV, 320 mAs/rot) with different simulated heart rates (HRs). The dose of a standard chest CT examination (120 kV, 160 mAs) was also measured. Effective dose of the chest pain protocol was 19.3/21.9 mSv (male/female, HR 60), 17.9/20.4 mSv (male/female, HR 80) and 14.7/16.7 mSv (male/female, HR 100). Effective dose of a standard chest examination was 6.3 mSv (males) and 7.2 mSv (females). Radiation dose of the chest pain protocol increases significantly with a lower heart rate for both males (p = 0.040) and females (p = 0.044). The average radiation dose of a standard chest CT examination is about 36.5% that of a CT examination performed for chest pain. Using DSCT, the evaluated chest pain protocol revealed a higher radiation exposure compared with standard chest CT. Furthermore, HRs markedly influenced the dose exposure when using the ECG-gated chest pain protocol.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 50 条
  • [1] Estimation of the radiation exposure of a chest pain protocol with ECG-gating in dual-source computed tomography
    Dominik Ketelsen
    Marie H. Luetkhoff
    Christoph Thomas
    Matthias Werner
    Markus Buchgeister
    Ilias Tsiflikas
    Anja Reimann
    Christof Burgstahler
    Andreas F. Kopp
    Claus D. Claussen
    Martin Heuschmid
    European Radiology, 2009, 19 : 37 - 41
  • [2] Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating
    Trabold, T
    Buchgeister, M
    Küttner, A
    Heuschmid, M
    Kopp, AF
    Schröder, S
    Claussen, CD
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (08): : 1051 - 1055
  • [3] Dual-source computed tomography: Estimation of radiation exposure of ECG-gated and ECG-triggered coronary angiography
    Ketelsen, Dominik
    Thomas, Christoph
    Werner, Matthias
    Luetkhoff, Marie H.
    Buchgeister, Markus
    Tsiflikas, Ilias
    Reimann, Anja
    Burgstahler, Christof
    Brodoefel, Harald
    Kopp, Andreas F.
    Claussen, Claus D.
    Heuschmid, Martin
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 73 (02) : 274 - 279
  • [4] Dual-source computed tomography in inpatients with atypical chest pain
    Arraiza, M.
    Arias, J.
    Broncano, J.
    Pueyo, J. C.
    Villanueva, A.
    Bastarrika, G.
    RADIOLOGIA, 2009, 51 (06): : 568 - 576
  • [5] Saving the patient the radiation: no need for ECG-gating during cardiac computed tomography
    Ector, Joris
    Heidbuchel, Hein
    EUROPACE, 2010, 12 (08): : 1053 - 1054
  • [6] Helical prospective ECG-gating in cardiac computed tomography: radiation dose and image quality
    DeFrance, Tony
    Dubois, Eric
    Gebow, Dan
    Ramirez, Alex
    Wolf, Florian
    Feuchtner, Gudrun M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (01): : 99 - 107
  • [7] Dual-source computed tomography in patients with acute chest pain: feasibility and image quality
    Thomas Schertler
    Hans Scheffel
    Thomas Frauenfelder
    Lotus Desbiolles
    Sebastian Leschka
    Paul Stolzmann
    Burkhardt Seifert
    Thomas G. Flohr
    Borut Marincek
    Hatem Alkadhi
    European Radiology, 2007, 17 : 3179 - 3188
  • [8] Dual-source computed tomography in patients with acute chest pain: feasibility and image quality
    Schertler, Thomas
    Scheffel, Hans
    Frauenfelder, Thomas
    Desbiolles, Lotus
    Leschka, Sebastian
    Stolzmann, Paul
    Seifert, Burkhardt
    Flohr, Thomas G.
    Marincek, Borut
    Alkadhi, Hatem
    EUROPEAN RADIOLOGY, 2007, 17 (12) : 3179 - 3188
  • [9] Helical prospective ECG-gating in cardiac computed tomography: radiation dose and image quality
    Tony DeFrance
    Eric Dubois
    Dan Gebow
    Alex Ramirez
    Florian Wolf
    Gudrun M. Feuchtner
    The International Journal of Cardiovascular Imaging, 2010, 26 : 99 - 107
  • [10] High-pitch dual-source CT angiography without ECG-gating for imaging the whole aorta: intraindividual comparison with standard pitch single-source technique without ECG-gating
    Manna, Carmelinda
    Silva, Mario
    Cobelli, Rocco
    Poggesi, Sara
    Rossi, Cristina
    Sverzellati, Nicola
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2017, 23 (04) : 293 - 299