Estimation of the radiation exposure of a chest pain protocol with ECG-gating in dual-source computed tomography

被引:36
|
作者
Ketelsen, Dominik [1 ]
Luetkhoff, Marie H. [1 ]
Thomas, Christoph [1 ]
Werner, Matthias [1 ]
Buchgeister, Markus [2 ]
Tsiflikas, Ilias [1 ]
Reimann, Anja [1 ]
Burgstahler, Christof [3 ]
Kopp, Andreas F. [1 ]
Claussen, Claus D. [1 ]
Heuschmid, Martin [1 ]
机构
[1] Univ Tubingen, Dept Diagnost & Intervent Radiol, Univ Tubingen Hosp, D-72076 Tubingen, Germany
[2] Univ Tubingen Hosp, Dept Radiotherapy & Radiooncol, Tubingen, Germany
[3] Univ Tubingen Hosp, Dept Cardiol, Tubingen, Germany
关键词
Dual-source computed tomography; Radiation exposure; Effective dose; Chest pain; ACUTE CORONARY SYNDROMES; TUBE-CURRENT MODULATION; MULTIDETECTOR ROW CT; EMERGENCY-ROOM; MULTISLICE CT; ANGIOGRAPHY; PATIENT; HISTORY; NOISE;
D O I
10.1007/s00330-008-1109-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to evaluate radiation exposure of a chest pain protocol with ECG-gated dual-source computed tomography (DSCT). An Alderson Rando phantom equipped with thermoluminescent dosimeters was used for dose measurements. Exposure was performed on a dual-source computed tomography system with a standard protocol for chest pain evaluation (120 kV, 320 mAs/rot) with different simulated heart rates (HRs). The dose of a standard chest CT examination (120 kV, 160 mAs) was also measured. Effective dose of the chest pain protocol was 19.3/21.9 mSv (male/female, HR 60), 17.9/20.4 mSv (male/female, HR 80) and 14.7/16.7 mSv (male/female, HR 100). Effective dose of a standard chest examination was 6.3 mSv (males) and 7.2 mSv (females). Radiation dose of the chest pain protocol increases significantly with a lower heart rate for both males (p = 0.040) and females (p = 0.044). The average radiation dose of a standard chest CT examination is about 36.5% that of a CT examination performed for chest pain. Using DSCT, the evaluated chest pain protocol revealed a higher radiation exposure compared with standard chest CT. Furthermore, HRs markedly influenced the dose exposure when using the ECG-gated chest pain protocol.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 50 条
  • [31] Accuracy of dual-source computed tomography coronary angiography: evaluation with a standardised protocol for cardiac surgeons
    Bedi, Harinder Singh
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (02) : 282 - 282
  • [32] Dual-source computed tomography may define cardiac contusion in patients with blunt chest trauma in ED
    Emet, Mucahit
    Saritemur, Murat
    Altuntas, Bayram
    Karaca, Leyla
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (06): : 865.e1 - 865.e3
  • [33] Computed Tomography Angiography with a 192-slice Dual-source Computed Tomography System: Improvements in Image Quality and Radiation Dose
    Linsen, Philip V. M.
    Coenen, Adriaan
    Lubbers, Marisa M.
    Dijkshoorn, Marcel L.
    Ouhlous, Mohamed
    Nieman, Koen
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2016, 6
  • [34] Visualization of anomalous coronary arteries on dual-source computed tomography
    G. J. de Jonge
    P. M. A. van Ooijen
    L. H. Piers
    R. Dikkers
    R. A. Tio
    T. P. Willems
    A. F. M. van den Heuvel
    F. Zijlstra
    M. Oudkerk
    European Radiology, 2008, 18 : 2425 - 2432
  • [35] Dynamic Myocardial Perfusion Imaging by Dual-Source Computed Tomography
    Parga Filho, Jose Rodrigues
    Lima Moraes Lima, Cintia Souza
    Lima, Felipe Gallego
    Jaques, Tiago da Silveira
    Rodrigues de Avila, Luiz Francisco
    Kalil Filho, Roberto
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2012, 98 (03) : E54 - E58
  • [36] Coronary revascularization treatment based on dual-source computed tomography
    Dikkers, R.
    Willems, T. P.
    Piers, L. H.
    de Jonge, G. J.
    Tio, R. A.
    van der Zaag-Loonen, H. J.
    van Ooijen, P. M. A.
    Zijlstra, F.
    Oudkerk, M.
    EUROPEAN RADIOLOGY, 2008, 18 (09) : 1800 - 1808
  • [37] Dual-source computed tomography coronary artery imaging in children
    Aurelio Secinaro
    Davide Curione
    Kristian Havmand Mortensen
    Teresa Pia Santangelo
    Paolo Ciancarella
    Carmela Napolitano
    Alessia Del Pasqua
    Andrew Mayall Taylor
    Paolo Ciliberti
    Pediatric Radiology, 2019, 49 : 1823 - 1839
  • [38] Dual-source computed tomography coronary artery imaging in children
    Secinaro, Aurelio
    Curione, Davide
    Mortensen, Kristian Havmand
    Santangelo, Teresa Pia
    Ciancarella, Paolo
    Napolitano, Carmela
    Del Pasqua, Alessia
    Taylor, Andrew Mayall
    Ciliberti, Paolo
    PEDIATRIC RADIOLOGY, 2019, 49 (13) : 1823 - 1839
  • [39] Visualization of anomalous coronary arteries on dual-source computed tomography
    de Jonge, G. J.
    van Ooijen, P. M. A.
    Piers, L. H.
    Dikkers, R.
    Tio, R. A.
    Willems, T. P.
    van den Heuvel, A. F. M.
    Zijlstra, F.
    Oudkerk, M.
    EUROPEAN RADIOLOGY, 2008, 18 (11) : 2425 - 2432
  • [40] Dynamic dual-source computed tomography imaging for myocardial perfusion
    Li, Allen
    Chan, Y. H.
    Wu, B. E.
    Lam, C. S.
    HONG KONG MEDICAL JOURNAL, 2019, 25 (01)