Estimation of the radiation exposure of a chest pain protocol with ECG-gating in dual-source computed tomography

被引:36
|
作者
Ketelsen, Dominik [1 ]
Luetkhoff, Marie H. [1 ]
Thomas, Christoph [1 ]
Werner, Matthias [1 ]
Buchgeister, Markus [2 ]
Tsiflikas, Ilias [1 ]
Reimann, Anja [1 ]
Burgstahler, Christof [3 ]
Kopp, Andreas F. [1 ]
Claussen, Claus D. [1 ]
Heuschmid, Martin [1 ]
机构
[1] Univ Tubingen, Dept Diagnost & Intervent Radiol, Univ Tubingen Hosp, D-72076 Tubingen, Germany
[2] Univ Tubingen Hosp, Dept Radiotherapy & Radiooncol, Tubingen, Germany
[3] Univ Tubingen Hosp, Dept Cardiol, Tubingen, Germany
关键词
Dual-source computed tomography; Radiation exposure; Effective dose; Chest pain; ACUTE CORONARY SYNDROMES; TUBE-CURRENT MODULATION; MULTIDETECTOR ROW CT; EMERGENCY-ROOM; MULTISLICE CT; ANGIOGRAPHY; PATIENT; HISTORY; NOISE;
D O I
10.1007/s00330-008-1109-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to evaluate radiation exposure of a chest pain protocol with ECG-gated dual-source computed tomography (DSCT). An Alderson Rando phantom equipped with thermoluminescent dosimeters was used for dose measurements. Exposure was performed on a dual-source computed tomography system with a standard protocol for chest pain evaluation (120 kV, 320 mAs/rot) with different simulated heart rates (HRs). The dose of a standard chest CT examination (120 kV, 160 mAs) was also measured. Effective dose of the chest pain protocol was 19.3/21.9 mSv (male/female, HR 60), 17.9/20.4 mSv (male/female, HR 80) and 14.7/16.7 mSv (male/female, HR 100). Effective dose of a standard chest examination was 6.3 mSv (males) and 7.2 mSv (females). Radiation dose of the chest pain protocol increases significantly with a lower heart rate for both males (p = 0.040) and females (p = 0.044). The average radiation dose of a standard chest CT examination is about 36.5% that of a CT examination performed for chest pain. Using DSCT, the evaluated chest pain protocol revealed a higher radiation exposure compared with standard chest CT. Furthermore, HRs markedly influenced the dose exposure when using the ECG-gated chest pain protocol.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 50 条
  • [41] Multiphase Evaluation of Myocardial Bridging with Dual-Source Computed Tomography
    Zhang, Long Jiang
    Yang, Gui Fen
    Zhou, Chang Sheng
    Huang, Wei
    Lu, Guang Ming
    Shiroishi, M. S.
    ACTA RADIOLOGICA, 2009, 50 (07) : 775 - 780
  • [42] Coronary revascularization treatment based on dual-source computed tomography
    R. Dikkers
    T. P. Willems
    L. H. Piers
    G. J. de Jonge
    R. A. Tio
    H. J. van der Zaag-Loonen
    P. M. A. van Ooijen
    F. Zijlstra
    M. Oudkerk
    European Radiology, 2008, 18 : 1800 - 1808
  • [43] ALCAPA syndrome demonstrated by dual-source computed tomography in an infant
    Vastel, Carine
    Magnier, Suzel
    Paula, Jean-Francois
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2009, 102 (12) : 855 - 856
  • [44] Prospective versus retrospective ECG-gating for 64-detector computed tomography of the coronary venous system in pigs
    Roule, Vincent
    Chazalviel, Laurent
    Young, Alan R.
    Lebon, Alain
    Beaudouin, Vincent
    Agostini, Denis
    Milliez, Paul
    Dacher, Jean-Nicolas
    Manrique, Alain
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2012, 105 (10) : 468 - 477
  • [45] Assessment of intimal tears in thoracic aortic dissection using ECG-gated dual-source computed tomography
    Michalowska, Ilona
    Szpakowski, Eugeniusz
    Furmanek, Mariusz
    Kusmierczyk, Mariusz
    Oleksiuk, Tomasz
    Kwiatek, Pawel
    Janaszek-Sitkowska, Hanna
    Legaszewski, Tomasz
    Rozanski, Jacek
    KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA, 2013, 10 (02): : 171 - 176
  • [46] Radiation Risks from Exposure to Chest Computed Tomography
    Huppmann, Michael V.
    Johnson, William B.
    Javitt, Marcia C.
    SEMINARS IN ULTRASOUND CT AND MRI, 2010, 31 (01) : 14 - 28
  • [47] Accuracy of dual-source computed tomography coronary angiography: evaluation with a standardised protocol for cardiac surgeons Reply
    Plass, Andre
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (02) : 283 - 283
  • [48] CORONARY COMPUTED TOMOGRAPHY ANGIOGRAPHY: COMPARISON BETWEEN FLASH SPIRAL AND RETROSPECTIVE ECG GATING DUAL SOURCE TECHNIQUES
    Srichai-Parsia, Monvadi Barbara
    Lim, Ruth P.
    Mannelli, Lorenzo
    Donnino, Robert
    Hiralal, Rajesh
    Ho, Corey K.
    Babb, James S.
    Jacobs, Jill E.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E672 - E672
  • [49] Radiation dose exposure of computed tomography coronary angiography: comparison of dual-source, 16-slice and 64-slice CT
    Rixe, J.
    Conradi, G.
    Rolf, A.
    Schmermund, A.
    Magedanz, A.
    Erkapic, D.
    Deetjen, A.
    Hamm, C. W.
    Dill, T.
    HEART, 2009, 95 (16) : 1337 - 1342
  • [50] Dual-source cardiac computed tomography: image quality and dose considerations
    Achenbach, Stephan
    Anders, Katharina
    Kalender, Willi A.
    EUROPEAN RADIOLOGY, 2008, 18 (06) : 1188 - 1198