Estimation of the radiation exposure of a chest pain protocol with ECG-gating in dual-source computed tomography

被引:36
|
作者
Ketelsen, Dominik [1 ]
Luetkhoff, Marie H. [1 ]
Thomas, Christoph [1 ]
Werner, Matthias [1 ]
Buchgeister, Markus [2 ]
Tsiflikas, Ilias [1 ]
Reimann, Anja [1 ]
Burgstahler, Christof [3 ]
Kopp, Andreas F. [1 ]
Claussen, Claus D. [1 ]
Heuschmid, Martin [1 ]
机构
[1] Univ Tubingen, Dept Diagnost & Intervent Radiol, Univ Tubingen Hosp, D-72076 Tubingen, Germany
[2] Univ Tubingen Hosp, Dept Radiotherapy & Radiooncol, Tubingen, Germany
[3] Univ Tubingen Hosp, Dept Cardiol, Tubingen, Germany
关键词
Dual-source computed tomography; Radiation exposure; Effective dose; Chest pain; ACUTE CORONARY SYNDROMES; TUBE-CURRENT MODULATION; MULTIDETECTOR ROW CT; EMERGENCY-ROOM; MULTISLICE CT; ANGIOGRAPHY; PATIENT; HISTORY; NOISE;
D O I
10.1007/s00330-008-1109-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the study was to evaluate radiation exposure of a chest pain protocol with ECG-gated dual-source computed tomography (DSCT). An Alderson Rando phantom equipped with thermoluminescent dosimeters was used for dose measurements. Exposure was performed on a dual-source computed tomography system with a standard protocol for chest pain evaluation (120 kV, 320 mAs/rot) with different simulated heart rates (HRs). The dose of a standard chest CT examination (120 kV, 160 mAs) was also measured. Effective dose of the chest pain protocol was 19.3/21.9 mSv (male/female, HR 60), 17.9/20.4 mSv (male/female, HR 80) and 14.7/16.7 mSv (male/female, HR 100). Effective dose of a standard chest examination was 6.3 mSv (males) and 7.2 mSv (females). Radiation dose of the chest pain protocol increases significantly with a lower heart rate for both males (p = 0.040) and females (p = 0.044). The average radiation dose of a standard chest CT examination is about 36.5% that of a CT examination performed for chest pain. Using DSCT, the evaluated chest pain protocol revealed a higher radiation exposure compared with standard chest CT. Furthermore, HRs markedly influenced the dose exposure when using the ECG-gated chest pain protocol.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 50 条
  • [21] Dual-source CT for chest pain assessment
    Johnson, Thorsten R. C.
    Nikolaou, Konstantin
    Becker, Alexander
    Leber, Alexander W.
    Rist, Carsten
    Wintersperger, Bernd J.
    Reiser, Maximilian F.
    Becker, Christoph R.
    EUROPEAN RADIOLOGY, 2008, 18 (04) : 773 - 780
  • [22] Dual-source CT for chest pain assessment
    Thorsten R. C. Johnson
    Konstantin Nikolaou
    Alexander Becker
    Alexander W. Leber
    Carsten Rist
    Bernd J. Wintersperger
    Maximilian F. Reiser
    Christoph R. Becker
    European Radiology, 2008, 18 : 773 - 780
  • [23] Is ECG triggering for motion artefact reduction in dual-source CT angiography of the ascending aorta still required with high-pitch scanning? The role of ECG-gating in high-pitch dual-source CT of the ascending aorta
    Wielandner, Alice
    Beitzke, Dietrich
    Schernthaner, Ruediger
    Wolf, Florian
    Langenberger, Christina
    Stadler, Alfred
    Loewe, Christian
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1064):
  • [24] Subtotal Cor Triatriatum on Dual-Source Computed Tomography
    Sharma, Arun
    Biradar, Basavraj
    Malhi, Amarinder S.
    Kumar, Sanjeev
    ANNALS OF THORACIC SURGERY, 2019, 107 (03): : E213 - E213
  • [25] Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography
    Laspas, Fotios
    Tsantioti, Dimitra
    Roussakis, Arkadios
    Kritikos, Nikolaos
    Efthimiadou, Roxani
    Kehagias, Dimitrios
    Andreou, John
    ACTA RADIOLOGICA, 2011, 52 (03) : 273 - 277
  • [26] Truncus arteriosus: Diagnosis with dual-source computed tomography angiography and low radiation dose
    Koplay, Mustafa
    Cimen, Derya
    Sivri, Mesut
    Guvenc, Osman
    Arslan, Derya
    Nayman, Alaaddin
    Oran, Bulent
    WORLD JOURNAL OF RADIOLOGY, 2014, 6 (11): : 886 - 889
  • [27] Radiation Dose and Image Quality of Prospective Triggering With Dual-Source Cardiac Computed Tomography
    Blankstein, Ron
    Shah, Amar
    Pale, Rodrigo
    Abbara, Suhny
    Bezerra, Hiram
    Bolen, Michael
    Mamuya, Wilfred S.
    Hoffmann, Udo
    Brady, Thomas J.
    Cury, Ricardo C.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (08): : 1168 - 1173
  • [28] The effect of heart rhythm on patient radiation dose with dual-source cardiac computed tomography
    Techasith, Tust
    Ghoshhajra, Brian B.
    Truong, Quynh A.
    Pale, Rodrigo
    Nasir, Khurram
    Bolen, Michael A.
    Hoffmann, Udo
    Cury, Ricardo C.
    Abbara, Suhny
    Brady, Thomas J.
    Blankstein, Ron
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (04) : 255 - 263
  • [29] Estimate of lifetime attributable risk of cancer associated with single radiation exposure from 64-slice prospective and retrospective ECG-gating computed tomography coronary angiography
    Faletra, F. F.
    Diliberto, R.
    Angeli, I. D.
    Pasotti, E.
    Averaimo, E.
    Klimusina, J.
    Klersy, C.
    Pedrazzini, G.
    Moccetti, T.
    Auricchio, A.
    EUROPEAN HEART JOURNAL, 2009, 30 : 748 - 749
  • [30] Accuracy of dual-source computed tomography coronary angiography: evaluation with a standardised protocol for cardiac surgeons
    Plass, Andre
    Azemaj, Naim
    Scheffel, Hans
    Desbiolles, Lotus
    Alkadhi, Hatem
    Genoni, Michele
    Falk, Volkmar
    Grunenfelder, Jurg
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 36 (06) : 1011 - 1017