Estimation of radiation exposure in 16-detector row computed tomography of the heart with retrospective ECG-gating

被引:1
|
作者
Trabold, T
Buchgeister, M
Küttner, A
Heuschmid, M
Kopp, AF
Schröder, S
Claussen, CD
机构
[1] Univ Tubingen, Abt Radiol Diagnost, Radiol Klin, D-72076 Tubingen, Germany
[2] Univ Tubingen, Abt Med Phys, Radioonkol Klin, D-72074 Tubingen, Germany
[3] Univ Tubingen, Abt Kardiol, Med Klin 3, D-72074 Tubingen, Germany
关键词
multidetector computed tomography; radiation exposure; effective dose; cardiac CT;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We sought to evaluate the radiation exposure of cardiac CT scans with 16-row multidetector computed tomography (MDCT). Additionally the possibility of dose reduction by using a ECG-controlled tube current modulation technique was evaluated. Methods and Material: An Alderson Rando phantom equipped with thermoluminescent dosimeters was used for dose measurements. Effective dose was calculated according to ICRP 60. Exposure was performed on a 16-row MDCT scanner with standard protocols for CT coronary calcium scoring (120 kV, 133 mAs, 12 x 1,5 mm) and CT coronary angiography (120 kV, 400 mAs, 12 x 0,75 mm). Exposure was repeated at a simulated heart rate of 60 bpm with ECG-pulsed tube current modulation. Results: Effective dose was 2,9 mSv (male) and 3,6 mSv (female) for the calcium scoring protocol. CT coronary angiography resulted in an effective dose of 8,1 mSv (male) and 10,9 mSv (female). Using ECG-pulsed tube current modulation radiation exposure can significant reduced: by 46% (1,6 mSv) in calcium scoring and by 47% (4,3 mSv) in CT coronary angiography. Conclusion: MDCT of the heart shows a significant radiation exposure, which can significantly be reduced by ECG-pulsed tube current modulation. Radiation exposure of cardiac MDCT is comparable to CT-examinations of chest or abdomen, but seem to be slightly higher compared to conventional coronary angiography.
引用
收藏
页码:1051 / 1055
页数:5
相关论文
共 50 条
  • [1] Estimation of radiation exposure with 16-detector row computed tomography of coronary artery
    Gilard, M
    Cornily, JC
    Mansourati, J
    Nonent, M
    Blanc, JJ
    Boschat, J
    EUROPEAN HEART JOURNAL, 2004, 25 : 472 - 472
  • [2] Estimation of the radiation exposure of a chest pain protocol with ECG-gating in dual-source computed tomography
    Ketelsen, Dominik
    Luetkhoff, Marie H.
    Thomas, Christoph
    Werner, Matthias
    Buchgeister, Markus
    Tsiflikas, Ilias
    Reimann, Anja
    Burgstahler, Christof
    Kopp, Andreas F.
    Claussen, Claus D.
    Heuschmid, Martin
    EUROPEAN RADIOLOGY, 2009, 19 (01) : 37 - 41
  • [3] Estimation of the radiation exposure of a chest pain protocol with ECG-gating in dual-source computed tomography
    Dominik Ketelsen
    Marie H. Luetkhoff
    Christoph Thomas
    Matthias Werner
    Markus Buchgeister
    Ilias Tsiflikas
    Anja Reimann
    Christof Burgstahler
    Andreas F. Kopp
    Claus D. Claussen
    Martin Heuschmid
    European Radiology, 2009, 19 : 37 - 41
  • [4] Prospective versus retrospective ECG-gating for 64-detector computed tomography of the coronary venous system in pigs
    Roule, Vincent
    Chazalviel, Laurent
    Young, Alan R.
    Lebon, Alain
    Beaudouin, Vincent
    Agostini, Denis
    Milliez, Paul
    Dacher, Jean-Nicolas
    Manrique, Alain
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2012, 105 (10) : 468 - 477
  • [5] Saving the patient the radiation: no need for ECG-gating during cardiac computed tomography
    Ector, Joris
    Heidbuchel, Hein
    EUROPACE, 2010, 12 (08): : 1053 - 1054
  • [6] Helical prospective ECG-gating in cardiac computed tomography: radiation dose and image quality
    DeFrance, Tony
    Dubois, Eric
    Gebow, Dan
    Ramirez, Alex
    Wolf, Florian
    Feuchtner, Gudrun M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (01): : 99 - 107
  • [7] Helical prospective ECG-gating in cardiac computed tomography: radiation dose and image quality
    Tony DeFrance
    Eric Dubois
    Dan Gebow
    Alex Ramirez
    Florian Wolf
    Gudrun M. Feuchtner
    The International Journal of Cardiovascular Imaging, 2010, 26 : 99 - 107
  • [8] Noninvasive visualization of coronary artery bypass grafts using 16-detector row computed tomography
    Schlosser, T
    Konorza, T
    Hunold, P
    Kühl, H
    Schmermund, A
    Barkhausen, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (06) : 1224 - 1229
  • [9] Coronary artery calcium score:: Influence of reconstruction interval at 16-detector row CT with retrospective electrocardiographic gating
    Schlosser, T
    Hunold, P
    Schmermund, A
    Kühl, H
    Waltering, KU
    Debatin, JF
    Barkhausen, J
    RADIOLOGY, 2004, 233 (02) : 586 - 589
  • [10] Estimate of lifetime attributable risk of cancer associated with single radiation exposure from 64-slice prospective and retrospective ECG-gating computed tomography coronary angiography
    Faletra, F. F.
    Diliberto, R.
    Angeli, I. D.
    Pasotti, E.
    Averaimo, E.
    Klimusina, J.
    Klersy, C.
    Pedrazzini, G.
    Moccetti, T.
    Auricchio, A.
    EUROPEAN HEART JOURNAL, 2009, 30 : 748 - 749