Comparison of air kerma standards for medium-energy x radiation between the MKEH and the IAEA

被引:1
|
作者
Csete, Istvan [1 ]
Czap, Ladislav [2 ]
Gomola, Igor [2 ]
机构
[1] Hungarian Trade Licensing Off MKEH, Budapest, Hungary
[2] IAEA, A-1400 Vienna, Austria
关键词
D O I
10.1088/0026-1394/49/1A/06011
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A comparison of the air kerma standards for medium-energy x radiation was performed between the MKEH and the IAEA. Two reference class ionization chambers of the IAEA, traceable to the PTB with volumes 1000 cm(3) and 100 cm(3), and the ISO 4037 N-40, N-60, N-120 and N-300 standard beam qualities were selected for the comparison. The calibration coefficients, N-K, were determined for both chambers at the MKEH in August 2011 and before and after this at the IAEA Dosimetry Laboratory. The comparison ratio of the calibration coefficients normalized to the previous comparison results of the PTB and MKEH primary air kerma standards were in the range from 0.989 to 0.994 for the beam qualities used. The relative expanded ( k = 2) uncertainty for each of these ratios is around 2 %.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Comparison of the standards for air kerma of the VNIIM and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Oborin, A. V.
    Villevalde, A. Y.
    METROLOGIA, 2011, 48
  • [42] Comparison of the standards for air kerma of the KRISS and the BIPM for 137Cs gamma radiation
    Kessler, C.
    Roger, P.
    Allisy-Roberts, P. J.
    Yi, Chul-Young
    METROLOGIA, 2010, 47
  • [43] Comparison of the standards for air kerma of the KRISS and the BIPM for 60Co gamma radiation
    Kessler, C.
    Yi, Chul-Young
    Chung, Jae-Pil
    Roger, P.
    Allisy-Roberts, P. J.
    METROLOGIA, 2010, 47
  • [44] Comparison of the standards for air kerma of the NRC and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    McCaffrey, J. P.
    Ross, C. K.
    METROLOGIA, 2010, 47
  • [45] Comparison of the standards for air kerma of the VSL and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    de Prez, L. A.
    van Dijk, E.
    METROLOGIA, 2010, 47
  • [46] Comparison of the standards for air kerma of the VNIIM and the BIPM for 137Cs gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Oborin, A. V.
    Villevalde, A. Y.
    METROLOGIA, 2011, 48
  • [47] Comparison of the standards for air kerma of the BEV and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Steurer, A.
    Baumgartner, A.
    Tiefenboeck, W.
    Gabris, F.
    METROLOGIA, 2010, 47
  • [48] Comparison of the standards for air kerma of the NIST and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Minniti, Ronaldo
    METROLOGIA, 2013, 50
  • [49] IAEA-SSDL bilateral comparisons for diagnostic level air kerma measurement standards
    Csete, Istvan
    Toroi, Paula
    Steuer, Andreas
    Hourdakis, Costas
    Gabris, Frantisek
    Jozela, Sibusiso
    Kosunen, Antti
    Cardoso, Joao
    Sochor, Vladimir
    Persson, Linda
    Cindro, Denis Glavic
    Arib, Mehenna
    Smekhov, Mark
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 47 : 9 - 15
  • [50] First international comparison of primary absorbed dose to water standards in the medium-energy X-ray range
    Bueermann, Ludwig
    Guerra, Antonio Stefano
    Pimpinella, Maria
    Pinto, Massimo
    De Pooter, Jacco
    De Prez, Leon
    Jansen, Bartel
    Denoziere, Marc
    Rapp, Benjamin
    METROLOGIA, 2016, 53