Comparison of the standards for air kerma of the KRISS and the BIPM for 60Co gamma radiation

被引:4
|
作者
Kessler, C. [1 ]
Yi, Chul-Young [2 ]
Chung, Jae-Pil [2 ]
Roger, P. [1 ]
Allisy-Roberts, P. J. [1 ]
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
[2] Korea Res Inst Stand & Sci, Taejon 305340, South Korea
关键词
CHAMBER;
D O I
10.1088/0026-1394/47/1A/06021
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A direct comparison of the standards for air kerma of the Korea Research Institute of Standards and Science (KRISS), Korea, and of the Bureau International des Poids et Mesures (BIPM) was carried out in the Co-60 radiation beam of the BIPM in 2010. The result, expressed as a ratio of the KRISS and the BIPM standards for air kerma, is 0.9995 with a combined standard uncertainty of 1.6 x 10(-3). The degrees of equivalence between the KRISS and the other participants in the key comparison, designated as BIPM. RI(I)-K1, have been calculated and the results are presented in the form of a matrix. A graphical presentation is also given.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Comparison of the standards for air kerma of the VNIIM and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Oborin, A. V.
    Villevalde, A. Y.
    METROLOGIA, 2011, 48
  • [2] Comparison of the standards for air kerma of the ARPANSA and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Lye, J.
    Oliver, C.
    METROLOGIA, 2011, 48
  • [3] Comparison of the standards for air kerma of the NRC and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    McCaffrey, J. P.
    Ross, C. K.
    METROLOGIA, 2010, 47
  • [4] Comparison of the standards for air kerma of the VSL and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    de Prez, L. A.
    van Dijk, E.
    METROLOGIA, 2010, 47
  • [5] Comparison of the standards for air kerma of the BEV and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Steurer, A.
    Baumgartner, A.
    Tiefenboeck, W.
    Gabris, F.
    METROLOGIA, 2010, 47
  • [6] Comparison of the standards for air kerma of the NIST and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Minniti, Ronaldo
    METROLOGIA, 2013, 50
  • [7] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the KRISS, Republic of Korea, and the BIPM in 60Co gamma radiation
    Kessler C.
    Burns D.
    Yi C.-Y.
    Kim Y.H.
    Seong Y.M.
    Metrologia, 2022, 59 (1 A)
  • [8] Comparison of the standards for air kerma of the KRISS and the BIPM for 137Cs gamma radiation
    Kessler, C.
    Roger, P.
    Allisy-Roberts, P. J.
    Yi, Chul-Young
    METROLOGIA, 2010, 47
  • [9] Comparison of the standards for air kerma of the NPL and the BIPM for 60Co γ rays
    Kessler, C.
    Allisy, P. J.
    Burns, D. T.
    Duane, S.
    Manning, J.
    Nutbrown, R.
    METROLOGIA, 2010, 47
  • [10] Comparisons of the standards for air kerma of the GUM and the BIPM for 60Co and 137Cs gamma radiation
    Allisy-Roberts, P. J.
    Kessler, C.
    Burns, D. T.
    Derlacinski, M.
    Kokocinski, J.
    METROLOGIA, 2011, 48