Coefficient-Free Blood Pressure Estimation Based on Pulse Transit Time-Cuff Pressure Dependence

被引:60
|
作者
Forouzanfar, Mohamad [1 ]
Ahmad, Saif [1 ]
Batkin, Izmail [1 ,2 ]
Dajani, Hilmi R. [1 ]
Groza, Voicu Z. [1 ]
Bolic, Miodrag [1 ]
机构
[1] Univ Ottawa, Sch Elect Engn & Comp Sci, Ottawa, ON K1N 6N5, Canada
[2] Ottawa Gen Hosp, Ottawa, ON K1H 8LC, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Blood pressure (BP); estimation; mathematical model; oscillometry; pulse transit time (PTT); OSCILLOMETRIC MAXIMUM; HYPERTENSION; VALIDATION; DEVICE;
D O I
10.1109/TBME.2013.2243148
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Oscillometry is a popular technique for automatic estimation of blood pressure (BP). However, most of the oscillometric algorithms rely on empirical coefficients for systolic and diastolic pressure evaluation that may differ in various patient populations, rendering the technique unreliable. A promising complementary technique for automatic estimation of BP, based on the dependence of pulse transit time (PTT) on cuff pressure (CP) (PTT-CP mapping), has been proposed in the literature. However, a theoretical grounding for this technique and a nonparametric BP estimation approach are still missing. In this paper, we propose a novel coefficient-free BP estimation method based on PTT-CP dependence. PTT is mathematically modeled as a function of arterial lumen area under the cuff. It is then analytically shown that PTT-CP mappings computed from various points on the arterial pulses can be used to directly estimate systolic, diastolic, and mean arterial pressure without empirical coefficients. Analytical results are cross-validated with a pilot investigation on ten healthy subjects where 150 simultaneous electrocardiogram and oscillometric BP recordings are analyzed. The results are encouraging whereby the mean absolute errors of the proposed method in estimating systolic and diastolic pressures are 5.31 and 4.51 mmHg, respectively, relative to the Food and Drug Administration approved Omron monitor. Our work thus shows promise toward providing robust and objective BP estimation in a variety of patients and monitoring situations.
引用
收藏
页码:1814 / 1824
页数:11
相关论文
共 50 条
  • [41] VALIDATION OF THE FREESCAN PULSE TRANSIT TIME-BASED BLOOD PRESSURE MONITOR
    Wu, Chih-Cheng
    Chao, Paul C. -P.
    JOURNAL OF HYPERTENSION, 2016, 34 : E142 - E142
  • [42] Continuous Systolic Blood Pressure Measurement Based on Improved Pulse Transit Time
    Xie, Meng
    Yang, Bo
    Chen, Cailian
    Guan, Xinping
    Hong, Peijun
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 5173 - 5178
  • [43] Non-contact Blood Pressure Measurement Based on Pulse Transit Time
    Chen Pengyong
    Zhou Zuofeng
    Zhao Ting
    Cao Jianzhong
    Yang Hongtao
    TENTH INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING (ICDIP 2018), 2018, 10806
  • [44] Image Based Contactless Blood Pressure Assessment using Pulse Transit Time
    Huang, Po-Wei
    Lin, Chun-Hao
    Chung, Meng-Liang
    Lin, Tzu-Min
    Wu, Bing-Fei
    2017 INTERNATIONAL AUTOMATIC CONTROL CONFERENCE (CACS), 2017,
  • [45] Estimation of systolic and diastolic pressure using the pulse transit time
    Ye, Soo-Young
    Kim, Gi-Ryon
    Jung, Dong-Keun
    Baik, Seong-Wan
    Jeon, Gye-Rok
    World Academy of Science, Engineering and Technology, 2010, 43 : 726 - 731
  • [46] Continuous Cuffless Blood Pressure Estimation Based on Pulse Transit Time: A New Evaluation with Invasive BP Reference
    Tang, Zunyi
    Chen, Ying
    Liu, Shing-Hong
    Kobayashi, Toshio
    Chen, Wenxi
    2019 IEEE 10TH INTERNATIONAL CONFERENCE ON AWARENESS SCIENCE AND TECHNOLOGY (ICAST 2019), 2019, : 516 - 520
  • [47] Regression-forests-based Estimation of Blood Pressure using the Pulse Transit Time Obtained by Facial Photoplethysmogram
    Yoshioka, Mototaka
    Bounyong, Souksakhone
    2017 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2017, : 3248 - 3253
  • [48] Impact of heart disease and calibration interval on accuracy of pulse transit time-based blood pressure estimation
    Ding, Xiaorong
    Zhang, Yuanting
    Tsang, Hon Ki
    PHYSIOLOGICAL MEASUREMENT, 2016, 37 (02) : 227 - 237
  • [49] Nonlinear Cuffless Blood Pressure Estimation of Healthy Subjects Using Pulse Transit Time and Arrival Time
    Esmaili, Amirhossein
    Kachuee, Mohammad
    Shabany, Mahdi
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (12) : 3299 - 3308
  • [50] Validation of ambulatory blood pressure monitoring and pulse transit time
    Liendo Martinez, K. H.
    Lopez-Padilla, D.
    De Miguel Diez, J.
    Villar Alvarez, F.
    Gomez Garcia, T.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60