Coefficient-Free Blood Pressure Estimation Based on Pulse Transit Time-Cuff Pressure Dependence

被引:60
|
作者
Forouzanfar, Mohamad [1 ]
Ahmad, Saif [1 ]
Batkin, Izmail [1 ,2 ]
Dajani, Hilmi R. [1 ]
Groza, Voicu Z. [1 ]
Bolic, Miodrag [1 ]
机构
[1] Univ Ottawa, Sch Elect Engn & Comp Sci, Ottawa, ON K1N 6N5, Canada
[2] Ottawa Gen Hosp, Ottawa, ON K1H 8LC, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Blood pressure (BP); estimation; mathematical model; oscillometry; pulse transit time (PTT); OSCILLOMETRIC MAXIMUM; HYPERTENSION; VALIDATION; DEVICE;
D O I
10.1109/TBME.2013.2243148
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Oscillometry is a popular technique for automatic estimation of blood pressure (BP). However, most of the oscillometric algorithms rely on empirical coefficients for systolic and diastolic pressure evaluation that may differ in various patient populations, rendering the technique unreliable. A promising complementary technique for automatic estimation of BP, based on the dependence of pulse transit time (PTT) on cuff pressure (CP) (PTT-CP mapping), has been proposed in the literature. However, a theoretical grounding for this technique and a nonparametric BP estimation approach are still missing. In this paper, we propose a novel coefficient-free BP estimation method based on PTT-CP dependence. PTT is mathematically modeled as a function of arterial lumen area under the cuff. It is then analytically shown that PTT-CP mappings computed from various points on the arterial pulses can be used to directly estimate systolic, diastolic, and mean arterial pressure without empirical coefficients. Analytical results are cross-validated with a pilot investigation on ten healthy subjects where 150 simultaneous electrocardiogram and oscillometric BP recordings are analyzed. The results are encouraging whereby the mean absolute errors of the proposed method in estimating systolic and diastolic pressures are 5.31 and 4.51 mmHg, respectively, relative to the Food and Drug Administration approved Omron monitor. Our work thus shows promise toward providing robust and objective BP estimation in a variety of patients and monitoring situations.
引用
收藏
页码:1814 / 1824
页数:11
相关论文
共 50 条
  • [31] Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation
    Ding, Xiaorong
    Yan, Bryan P.
    Zhang, Yuan-Ting
    Liu, Jing
    Zhao, Ni
    Tsang, Hon Ki
    SCIENTIFIC REPORTS, 2017, 7
  • [32] Pulse Transit Time Based Continuous Cuffless Blood Pressure Estimation: A New Extension and A Comprehensive Evaluation
    Xiaorong Ding
    Bryan P. Yan
    Yuan-Ting Zhang
    Jing Liu
    Ni Zhao
    Hon Ki Tsang
    Scientific Reports, 7
  • [33] Pulse Transit Time-based Blood Pressure Estimation Using Hilbert-Huang Transform
    Zhang, Qiao
    Shi, Yang
    Teng, Daniel
    Dinh, Anh
    Ko, Seok-Bum
    Chen, Li
    Basran, Jenny
    Dal Bello-Haas, Vanina
    Choi, Younhee
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 1785 - +
  • [34] Cuff-Less Blood Pressure Estimation Using Pulse Waveform Analysis and Pulse Arrival Time
    Yoon, Young-Zoon
    Kang, Jae Min
    Kwon, Yongjoo
    Park, Sangyun
    Noh, Seungwoo
    Kim, Younho
    Park, Jongae
    Hwang, Sung Woo
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2018, 22 (04) : 1068 - 1074
  • [35] Cuff-Less Continuous Blood Pressure Monitoring System Using Pulse Transit Time Techniques
    Zaki, Wan Suhaimizan Wan
    Correia, Ricardo
    Korposh, Serhiy
    Hayes-Gill, Barrie R.
    Morgan, Stephen P.
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2016, 8 (01): : 51 - 57
  • [36] Noninvasive Cuffless Blood Pressure Estimation Using Pulse Transit Time and Impedance Plethysmography
    Toan Huu Huynh
    Jafari, Roozbeh
    Chung, Wan-Young
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2019, 66 (04) : 967 - 976
  • [37] Optimizing Non-Invasive Blood Pressure Estimation Using Pulse Transit Time
    Jeong, In Cheol
    Finkelstein, Joseph
    MEDINFO 2013: PROCEEDINGS OF THE 14TH WORLD CONGRESS ON MEDICAL AND HEALTH INFORMATICS, PTS 1 AND 2, 2013, 192 : 1198 - 1198
  • [38] Estimation of pulse transit time using two diametric blood pressure waveform measurements
    Hahn, Jin-Oh
    Reisner, Andrew T.
    Asada, H. Harry
    MEDICAL ENGINEERING & PHYSICS, 2010, 32 (07) : 753 - 759
  • [39] Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio
    Gholamhosseini, Hamid
    Baig, Mirza
    Rastegar, Solmaz
    Linden, Maria
    PROCEEDINGS OF THE 15TH INTERNATIONAL CONFERENCE ON WEARABLE MICRO AND NANO TECHNOLOGIES FOR PERSONALIZED HEALTH (PHEALTH 2018), 2018, 249 : 77 - 83
  • [40] Correction Factor Estimation for a Parametric Model between Pulse Transit Time and Systolic Blood Pressure, for Non-Invasive Blood Pressure Estimation
    De Alwis, W. U. C.
    Rajapaksha, R. N. S.
    Ranaweera, N. N. S.
    Pitigalaarachchi, P. A. P. M. B.
    Pasqual, A.
    TENCON 2017 - 2017 IEEE REGION 10 CONFERENCE, 2017, : 2620 - 2625