Empirical dead-time corrections for synchrotron sources

被引:19
|
作者
Walko, D. A. [1 ]
Arms, D. A. [1 ]
Landahl, E. C. [1 ]
机构
[1] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
关键词
dead-time; photon detector; synchrotron fill pattern; data correction;
D O I
10.1107/S0909049508022358
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An experimental comparison of models for performing dead-time corrections of photon-counting detectors at synchrotron sources is presented. The performance of several detectors in the three operating modes of the Advanced Photon Source is systematically compared, with particular emphasis on asymmetric fill patterns. Several simple and well known correction formulas are evaluated. The results demonstrate the critical importance of detector speed and synchrotron fill pattern in selecting the proper dead-time correction.
引用
收藏
页码:612 / 617
页数:6
相关论文
共 50 条
  • [41] RATEMETER WITH DEAD-TIME CORRECTION
    JANKA, K
    KULMALA, V
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1983, 54 (11): : 1573 - 1574
  • [42] 2DOF discrete dead-time compensators for stable and integrative processes with dead-time
    Torrico, BC
    Normey-Rico, JE
    JOURNAL OF PROCESS CONTROL, 2005, 15 (03) : 341 - 352
  • [43] Dead-Time Compensation for the First-Order Dead-Time Processes: Towards a Broader Overview
    Huba, Mikulas
    Bistak, Pavol
    Vrancic, Damir
    Zakova, Katarina
    MATHEMATICS, 2021, 9 (13)
  • [44] AN EXPERIMENTAL STUDY OF DEAD-TIME ERRORS IN COUNTING PARTICLES FROM PULSED SOURCES
    WESTCOTT, CH
    GREENBERG, JS
    PHYSICAL REVIEW, 1951, 83 (01): : 242 - 242
  • [45] High-rate dead-time corrections in a general purpose digital pulse processing system
    Abbene, Leonardo
    Gerardi, Gaetano
    JOURNAL OF SYNCHROTRON RADIATION, 2015, 22 : 1190 - 1201
  • [46] INSTRUMENTAL DEAD-TIME AND ITS RELATIONSHIP WITH MATRIX CORRECTIONS IN X-RAY-FLUORESCENCE ANALYSIS
    THOMAS, IL
    HAUKKA, MT
    ANDERSON, DH
    ANALYTICA CHIMICA ACTA, 1979, 105 (01) : 177 - 184
  • [47] ELIMINATION OF DEAD-TIME CORRECTIONS IN MONITORED GEIGER-COUNTER X-RAY MEASUREMENTS
    EASTABROOK, JN
    HUGHES, JW
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1953, 30 (09): : 317 - 320
  • [48] Simple robust dead-time compensator for first-order plus dead-time unstable processes
    Normey-Rico, Julio E.
    Camacho, Eduardo. F.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2008, 47 (14) : 4784 - 4790
  • [49] Dead-time analysis of digital spectrometers
    Cardoso, JM
    Simoes, JB
    Correia, CMBA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 522 (03): : 487 - 494
  • [50] IMPROVED DEAD-TIME COMPENSATOR CONTROLLERS
    PALMOR, ZJ
    POWERS, DV