Empirical dead-time corrections for synchrotron sources

被引:19
|
作者
Walko, D. A. [1 ]
Arms, D. A. [1 ]
Landahl, E. C. [1 ]
机构
[1] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
关键词
dead-time; photon detector; synchrotron fill pattern; data correction;
D O I
10.1107/S0909049508022358
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An experimental comparison of models for performing dead-time corrections of photon-counting detectors at synchrotron sources is presented. The performance of several detectors in the three operating modes of the Advanced Photon Source is systematically compared, with particular emphasis on asymmetric fill patterns. Several simple and well known correction formulas are evaluated. The results demonstrate the critical importance of detector speed and synchrotron fill pattern in selecting the proper dead-time correction.
引用
收藏
页码:612 / 617
页数:6
相关论文
共 50 条
  • [11] CORRECTIONS FOR DEAD-TIME OF COUNTERS IN COINCIDENCE SYSTEMS
    WESTCOTT, CH
    KIRKALDY, JS
    PHYSICAL REVIEW, 1953, 91 (02): : 495 - 495
  • [12] DEAD-TIME CORRECTIONS IN DETECTION EXPERIMENTS ON NUCLEAR STATISTICS
    MADERO, CC
    CORCUERA, R
    SCHILMAN, H
    NUCLEAR INSTRUMENTS & METHODS, 1968, 66 (02): : 270 - &
  • [13] ON THE USE OF A DEAD-TIME METER FOR PILE-UP CORRECTIONS
    TICH, NN
    DAS, HA
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1991, 155 (06): : 403 - 410
  • [14] DEAD-TIME CORRECTIONS IN MEASUREMENT OF SHORT-LIVED RADIONUCLIDES
    AXTON, EJ
    RYVES, TB
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1963, 14 (03): : 159 - &
  • [15] COINCIDENCE COUNTING CORRECTIONS FOR DEAD-TIME LOSS AND ACCIDENTAL COINCIDENCES
    BRYANT, J
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1963, 14 (03): : 143 - &
  • [16] Practical considerations for establishing dead-time corrections in quantitative SPECT imaging
    Cohalan, Claire
    Morin, Marc-Andre
    Leblond, Antoine
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (02):
  • [17] Simple dead-time corrections for discrete time series of non-Poisson data
    Larsen, Michael L.
    Kostinski, Alexander B.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (09)
  • [18] Dead-time Investigation of SiPMs for Application at Pulsed Muon Sources
    Pooley, D. E.
    Cottrell, S. P.
    Huzan, M. S.
    Pollastri, L.
    Schooneveld, E. M.
    Rhodes, N. J.
    Baker, P. J.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [19] Paralyzable and non-paralyzable dead-time corrections for the neutron detectors of the kuca facility driven by external neutron sources
    Talamo, Alberto
    Gohar, Yousry
    Yamanaka, Masao
    Pyeon, Cheol Ho
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2020, 57 (02) : 157 - 168