Empirical dead-time corrections for synchrotron sources

被引:19
|
作者
Walko, D. A. [1 ]
Arms, D. A. [1 ]
Landahl, E. C. [1 ]
机构
[1] Argonne Natl Lab, Adv Photon Source, Argonne, IL 60439 USA
关键词
dead-time; photon detector; synchrotron fill pattern; data correction;
D O I
10.1107/S0909049508022358
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An experimental comparison of models for performing dead-time corrections of photon-counting detectors at synchrotron sources is presented. The performance of several detectors in the three operating modes of the Advanced Photon Source is systematically compared, with particular emphasis on asymmetric fill patterns. Several simple and well known correction formulas are evaluated. The results demonstrate the critical importance of detector speed and synchrotron fill pattern in selecting the proper dead-time correction.
引用
收藏
页码:612 / 617
页数:6
相关论文
共 50 条
  • [1] Empirical dead-time corrections for energy-resolving detectors at synchrotron sources
    Walko, D. A.
    Arms, D. A.
    Miceli, A.
    Kastengren, A. L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 649 (01): : 81 - 83
  • [2] Experimental tests of dead-time corrections
    von Möllendorff, U
    Giese, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 498 (1-3): : 453 - 458
  • [3] DEAD-TIME CORRECTIONS FOR MULTIPLICITY COUNTERS
    DYTLEWSKI, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 305 (02): : 492 - 494
  • [4] On dead-time corrections for estimating rates
    Willink, R.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (01)
  • [5] DEAD-TIME CORRECTIONS FOR SLOW COUNTING SYSTEMS
    CRANNELL, H
    DANFORTH, D
    NUCLEAR INSTRUMENTS & METHODS, 1967, 55 (02): : 372 - &
  • [6] AN ALTERNATIVE APPROACH TO THE CORRECTIONS OF DEAD-TIME LOSSES
    SABOL, J
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-LETTERS, 1988, 127 (04): : 269 - 273
  • [7] DEAD-TIME CORRECTIONS TO PHOTON COUNTING DISTRIBUTIONS
    JOHNSON, FA
    JONES, R
    MCLEAN, TP
    PIKE, ER
    PHYSICAL REVIEW LETTERS, 1966, 16 (13) : 589 - &
  • [8] DEAD-TIME CORRECTIONS FOR MULTIPLEXER ANALYZER SYSTEMS
    BURGMER, W
    KLEIN, H
    NUCLEAR INSTRUMENTS & METHODS, 1975, 123 (02): : 371 - 377
  • [9] DEAD-TIME CORRECTIONS TO STATISTICAL DISTRIBUTION OF PHOTOELECTRONS
    BEDARD, G
    PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON, 1967, 90 (567P): : 131 - &
  • [10] EVALUATION OF DEAD-TIME CORRECTIONS IN EDS SYSTEMS
    BLOOMFIELD, DJ
    LOVE, G
    SCOTT, VD
    X-RAY SPECTROMETRY, 1983, 12 (01) : 2 - 7