Comparison between cuff-based and radial tonometry exercise-induced central blood pressure

被引:6
|
作者
Morales-Acuna, Francisco [1 ]
Ratcliffe, Brycen [2 ]
Harrison, Caleb [2 ]
Crowe, Sierra [2 ]
Bockover, Evan [2 ]
Pawlak, Robert [2 ]
Gurovich, Alvaro N. [1 ]
机构
[1] Univ Texas El Paso, Coll Hlth Sci, Dept Rehabil Sci, 1851 Wiggins Way, El Paso, TX 79968 USA
[2] Indiana State Univ, Dept Appl Med & Rehabil, Coll Hlth & Human Serv, Terre Haute, IN 47809 USA
关键词
Exercise-induced central blood pressure; Pulse wave analysis; Cuff-based device; Radial tonometer; AUGMENTATION INDEX; SPHYGMOCOR XCEL; VALIDATION; DEVICE; RELIABILITY; DISEASE; AMPLIFICATION; HYPERTENSION; STANDARDS; RESPONSES;
D O I
10.1007/s00421-019-04079-9
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
PurposeNon-invasive central blood pressure assessed during exercise may provide better cardiovascular prognostic than measurements taken at rest. Radial tonometry is the only technique validated to perform this type of assessment; however, it relies on the experience of the tester. Cuff-based devices have been developed to avoid operator dependency, although these systems have yet to be validated during exercise. The purpose of this study was to compare exercise-induced central blood pressure estimations between a cuff-based device and radial tonometry.MethodsTwenty young healthy subjects were recruited to perform a three-workload steady-state exercise test at blood lactate levels of <2, 2-4, and >4mmol/L, respectively. Central systolic and diastolic blood pressure (cSBP and cDBP, respectively), central pulse pressure (cPP), and augmentation index (AIx) were assessed at rest and during each workload with a cuff-based device and radial tonometry. Statistical analysis included Bland-Altman analysis for agreement between techniques. Agreement was considered when 95% of the data set for each central blood pressure parameter was within 1.96 standard deviations from the mean difference. Significance was considered at =0.05.ResultsCentral blood pressure measurements with the cuff device were obtained only at rest and during low-intensity exercise. During low-intensity exercise, all measurements showed agreement between both devices (cSBP 95% CI [- 6.0 to 10.7], cDBP 95% CI [- 4.5 to 6.3], cPP 95% CI [- 4.7 to 8.3], and AIx (95% CI [- 20.1 to 22.2]).ConclusionA cuff-based device can estimate central blood pressure at low-intensity exercise, without operator dependency, and showing agreement to radial tonometry.
引用
收藏
页码:901 / 911
页数:11
相关论文
共 50 条
  • [21] The effect of arterial stiffness on cuff-based blood pressure measurement
    Ma, Yuxiang
    Chen, Ying
    Ma, Yinji
    Feng, Xue
    EXTREME MECHANICS LETTERS, 2021, 48
  • [22] Blood Pressure Measurement: From Cuff-Based to Contactless Monitoring
    Man, Ping-Kwan
    Cheung, Kit-Leong
    Sangsiri, Nawapon
    Shek, Wilfred Jin
    Wong, Kwan-Long
    Chin, Jing-Wei
    Chan, Tsz-Tai
    So, Richard Hau-Yue
    HEALTHCARE, 2022, 10 (10)
  • [23] The comparison, of direct measurement of central blood pressure and noninvasive evaluation by radial artery tonometry
    Takazawa, Kenji
    Kobayashi, Hiroshi
    Kino, Mineko
    Aizawa, Akira
    CIRCULATION, 2007, 116 (16) : 608 - 608
  • [24] P1.01 Validation of a Brachial Cuff-Based Method for Assessing Central Blood Pressure
    T. Weber
    S. Wassertheurer
    C. Mayer
    B. Hametner
    J. Kropf
    B. Eber
    Artery Research, 2010, 4 (4) : 153 - 153
  • [25] CENTRAL BLOOD PRESSURE IN CHILDREN: COMPARISON OF CAROTID WALL TRACKING AND RADIAL APPLANATION TONOMETRY
    Watt, Louise
    Milne, Laura
    Sofocleous, Paula
    Chowienczyk, Phil
    Sinha, Manish D.
    PEDIATRIC NEPHROLOGY, 2013, 28 (08) : 1634 - 1635
  • [26] COMPARISON OF EFFECTS OF PERIPHERAL VASCULATURE ON TONOMETRIC RADIAL PULSE AND CUFF-BASED BRACHIAL PULSE WAVEFORM AS USED IN ESTIMATION OF CENTRAL AORTIC PRESSURE
    Butlin, M.
    Hathway, P.
    Turner, M.
    Avolio, A. P.
    JOURNAL OF HYPERTENSION, 2015, 33 : E98 - E99
  • [27] Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method
    Heiko Gesche
    Detlef Grosskurth
    Gert Küchler
    Andreas Patzak
    European Journal of Applied Physiology, 2012, 112 : 309 - 315
  • [28] Comparing blood pressure measurements between a photoplethysmography-based and a standard cuff-based manometry device
    Nachman, Dean
    Gepner, Yftach
    Goldstein, Nir
    Kabakov, Eli
    Ben Ishay, Arik
    Littman, Romi
    Azmon, Yuval
    Jaffe, Eli
    Eisenkraft, Arik
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [29] Optimization and validation of a suprasystolic brachial cuff-based method for noninvasively estimating central aortic blood pressure
    Zhang, Xujie
    Wang, Yue
    Yin, Zhaofang
    Liang, Fuyou
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2024, 40 (03)
  • [30] Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method
    Gesche, Heiko
    Grosskurth, Detlef
    Kuechler, Gert
    Patzak, Andreas
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2012, 112 (01) : 309 - 315