The effect of arterial stiffness on cuff-based blood pressure measurement

被引:4
|
作者
Ma, Yuxiang [1 ]
Chen, Ying [2 ,3 ]
Ma, Yinji [1 ]
Feng, Xue [1 ]
机构
[1] Tsinghua Univ, Ctr Flexible Elect Technol, Dept Engn Mech, Beijing 100084, Peoples R China
[2] Inst Flexible Elect Technol THU, Jiaxing 314000, Peoples R China
[3] Qiantang Sci & Technol Innovat Ctr, Hangzhou 310016, Peoples R China
基金
中国国家自然科学基金;
关键词
Cuff-based blood pressure measurement; Arterial collapse; Arterial stiffness; Arteriosclerosis; KOROTKOFF SOUNDS; BRACHIAL-ARTERY; PSEUDOHYPERTENSION;
D O I
10.1016/j.eml.2021.101298
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Cuff-based blood pressure measurement is the gold standard method for blood pressure monitoring. However, the wall of the sclerotic arteries (stiffen or thicken) generates extra resistance to the cuff pressure in the cuff-based blood pressure measurement, which tends to overestimate the blood pressure. This paper uses a collapse model to study the arterial deformation under the cuff pressure in the cuff-based blood pressure measurement, which gives the effects of arterial stiffness on measured systolic and diastolic blood pressure by cuff-based method, respectively. The results have general utility for future work in improving the accuracy of cuff-based BP measurement. (C) 2021 Published by Elsevier Ltd.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] VALIDATION OF AMBULATORY CUFF-BASED DEVICES FOR CENTRAL AORTIC BLOOD PRESSURE AND ARTERIAL STIFFNESS MEASUREMENT
    Butlin, M.
    Al Qahtani
    Quasem, A.
    Avolio, A. P.
    HYPERTENSION, 2015, 65 (05) : E34 - E34
  • [2] Cuff-based blood pressure measurement: challenges and solutions
    Pilz, N.
    Picone, D. S.
    Patzak, A.
    Opatz, O. S.
    Lindner, T.
    Fesseler, L.
    Heinz, V.
    Bothe, T. L.
    BLOOD PRESSURE, 2024, 33 (01)
  • [3] Blood Pressure Measurement: From Cuff-Based to Contactless Monitoring
    Man, Ping-Kwan
    Cheung, Kit-Leong
    Sangsiri, Nawapon
    Shek, Wilfred Jin
    Wong, Kwan-Long
    Chin, Jing-Wei
    Chan, Tsz-Tai
    So, Richard Hau-Yue
    HEALTHCARE, 2022, 10 (10)
  • [4] Effect of tissue mechanical properties on cuff-based blood pressure measurements
    Lan, H.
    Al-Jumaily, A. M.
    Lowe, A.
    Hing, W.
    MEDICAL ENGINEERING & PHYSICS, 2011, 33 (10) : 1287 - 1292
  • [5] AN EXPLANATION FOR UNDERESTIMATION OF SYSTOLIC PRESSURE IN CUFF-BASED MEASUREMENT
    Bassil, Kate
    Agarwal, Anurag
    Celler, Branko
    JOURNAL OF HYPERTENSION, 2024, 42
  • [6] Insights into oscillometry: An Experimental Study for Improvement of Cuff-Based Blood Pressure Measurement Technology
    Bogatu, L.
    Bresch, E.
    Muehlsteff, J.
    Smink, J.
    Woerlee, P.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 7068 - 7071
  • [7] CUFF-LESS BLOOD PRESSURE MEASUREMENT USING THE PULSE TRANSIT TIME - A COMPARISON TO CUFF-BASED OSCILLOMETRIC 24 HOUR BLOOD PRESSURE MEASUREMENT IN CHILDREN
    Hulpke-Wette, M.
    Goehler, A.
    Hofmann, E.
    Kuechler, G.
    JOURNAL OF HYPERTENSION, 2018, 36 : E73 - E73
  • [8] Blood Pressure Estimation Algorithm by a Cuff-Based Monitoring Unit
    Lopez-Lozada, Elizabeth
    Perez-Martinez, David
    Barragan-Vazquez, Diana Patricia
    Montiel-Perez, Yalja
    Sossa-Azuela, Juan Humberto
    COMPUTACION Y SISTEMAS, 2023, 27 (04): : 1047 - 1056
  • [9] Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method
    Heiko Gesche
    Detlef Grosskurth
    Gert Küchler
    Andreas Patzak
    European Journal of Applied Physiology, 2012, 112 : 309 - 315
  • [10] IMPROVED AGREEMENT OF A CUFFLESS 24 HOUR BLOOD PRESSURE MEASUREMENT DEVICE COMPARED TO CUFF-BASED STANDARD MEASUREMENT
    Krisai, P.
    Socrates, T.
    Meienberg, A.
    Mayr, M.
    Vischer, A. S.
    Burkard, T.
    JOURNAL OF HYPERTENSION, 2019, 37 : E129 - E130