Comparison between cuff-based and radial tonometry exercise-induced central blood pressure

被引:6
|
作者
Morales-Acuna, Francisco [1 ]
Ratcliffe, Brycen [2 ]
Harrison, Caleb [2 ]
Crowe, Sierra [2 ]
Bockover, Evan [2 ]
Pawlak, Robert [2 ]
Gurovich, Alvaro N. [1 ]
机构
[1] Univ Texas El Paso, Coll Hlth Sci, Dept Rehabil Sci, 1851 Wiggins Way, El Paso, TX 79968 USA
[2] Indiana State Univ, Dept Appl Med & Rehabil, Coll Hlth & Human Serv, Terre Haute, IN 47809 USA
关键词
Exercise-induced central blood pressure; Pulse wave analysis; Cuff-based device; Radial tonometer; AUGMENTATION INDEX; SPHYGMOCOR XCEL; VALIDATION; DEVICE; RELIABILITY; DISEASE; AMPLIFICATION; HYPERTENSION; STANDARDS; RESPONSES;
D O I
10.1007/s00421-019-04079-9
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
PurposeNon-invasive central blood pressure assessed during exercise may provide better cardiovascular prognostic than measurements taken at rest. Radial tonometry is the only technique validated to perform this type of assessment; however, it relies on the experience of the tester. Cuff-based devices have been developed to avoid operator dependency, although these systems have yet to be validated during exercise. The purpose of this study was to compare exercise-induced central blood pressure estimations between a cuff-based device and radial tonometry.MethodsTwenty young healthy subjects were recruited to perform a three-workload steady-state exercise test at blood lactate levels of <2, 2-4, and >4mmol/L, respectively. Central systolic and diastolic blood pressure (cSBP and cDBP, respectively), central pulse pressure (cPP), and augmentation index (AIx) were assessed at rest and during each workload with a cuff-based device and radial tonometry. Statistical analysis included Bland-Altman analysis for agreement between techniques. Agreement was considered when 95% of the data set for each central blood pressure parameter was within 1.96 standard deviations from the mean difference. Significance was considered at =0.05.ResultsCentral blood pressure measurements with the cuff device were obtained only at rest and during low-intensity exercise. During low-intensity exercise, all measurements showed agreement between both devices (cSBP 95% CI [- 6.0 to 10.7], cDBP 95% CI [- 4.5 to 6.3], cPP 95% CI [- 4.7 to 8.3], and AIx (95% CI [- 20.1 to 22.2]).ConclusionA cuff-based device can estimate central blood pressure at low-intensity exercise, without operator dependency, and showing agreement to radial tonometry.
引用
收藏
页码:901 / 911
页数:11
相关论文
共 50 条
  • [41] CUFF-BASED AMBULATORY BLOOD PRESSURE MEASUREMENT CAUSES AROUSAL REACTIONS AND RAISES SYSTOLIC BLOOD PRESSURE AT NIGHT - COMPARISON WITH BEAT-TO-BEAT AND CUFF-LESS METHOD
    Kuechler, G.
    Gehring, J.
    Fiedel, C.
    Schmitt, D.
    Voelker, W.
    Gohler, A.
    JOURNAL OF HYPERTENSION, 2017, 35 : E81 - E82
  • [42] Comparison of effects of peripheral vasculature on tonometric radial pulse and cuff-based brachial pulse waveform as used in estimation of central aortic pressures
    Butlin, Mark
    Tan, Isabella
    Qasem, Ahmad
    Avolio, Alberto P.
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [43] Insights into oscillometry: An Experimental Study for Improvement of Cuff-Based Blood Pressure Measurement Technology
    Bogatu, L.
    Bresch, E.
    Muehlsteff, J.
    Smink, J.
    Woerlee, P.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 7068 - 7071
  • [44] P2.11: The Impact of Atrial Fibrillation and Pacemakers on Accuracy of Central Blood Pressure Measured by a Novel Cuff-Based Technique
    Z. Sabahi
    M. Butlin
    C. Yeung
    A. P. Avolio
    E. Barin
    Artery Research, 2013, 7 (3-4) : 122 - 122
  • [45] Assessing the Accuracy of Systolic Aortic Pressure Estimation From a Brachial Cuff Alone: A Comparison With Radial Tonometry
    Chemla, Denis
    Agnoletti, Davide
    Attal, Pierre
    Millasseau, Sandrine
    Blacher, Jacques
    Jozwiak, Mathieu
    AMERICAN JOURNAL OF HYPERTENSION, 2024, 37 (08) : 549 - 553
  • [46] Observations of the Exercise-Induced Interarm Blood Pressure Difference
    Walsh, Maureen A.
    Clarke, Melanie M.
    Allen, Sarah R.
    Holmstrup, Michael E.
    Lin, Yen-Kuang
    Jensen, Brock T.
    TRANSLATIONAL JOURNAL OF THE AMERICAN COLLEGE OF SPORTS MEDICINE, 2020, 5 (11)
  • [47] Exercise-Induced Leg Pain and High Blood Pressure
    Olin, Jeffrey W.
    Kadian-Dodov, Daniella
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (04): : 412 - 413
  • [48] Method-comparison study between a watch-like sensor and a cuff-based device for 24-h ambulatory blood pressure monitoring
    Proenca, Martin
    Ambuhl, Jeremias
    Bonnier, Guillaume
    Meister, Theo A.
    Valentin, Jeremy
    Soria, Rodrigo
    Ferrario, Damien
    Lemay, Mathieu
    Rexhaj, Emrush
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [49] Aerobic exercise-induced change in blood pressure is associated with change in reflction component of blood pressure: Evaluation using radial augmentation index
    Tabara, Y
    Kohara, K
    Oshiumi, A
    Miyawaki, Y
    Kobayashi, T
    Miki, T
    AMERICAN JOURNAL OF HYPERTENSION, 2004, 17 (05) : 136A - 136A
  • [50] Cuff-Based Oscillometric Measurements of Central Hemodynamics: Factors Influencing Central Augmentation Pressure in Normotensive Japanese Individuals
    Obayashi, Masakazu
    Kobayashi, Shigeki
    Kohno, Michiaki
    Nakashima, Tomoko
    Yano, Masafumi
    PULSE, 2018, 6 (3-4) : 161 - 168