Evaluation of four pediatric cardiopulmonary bypass circuits in terms of perfusion quality and capturing gaseous microemboli

被引:14
|
作者
Mathis, R. K. [1 ]
Lin, J. [1 ]
Dogal, N. M. [1 ]
Qiu, F. [1 ]
Kunselman, A.
Wang, S. [1 ]
Uendar, A. [1 ,2 ,3 ]
机构
[1] Penn State Hershey Childrens Hosp, Penn State Hershey Coll Med, Penn State Milton S Hershey Med Ctr, Penn State Hershey Pediat Cardiovasc Res Ctr,Dept, Hershey, PA USA
[2] Penn State Hershey Childrens Hosp, Penn State Hershey Coll Med, Penn State Milton S Hershey Med Ctr, Dept Surg, Hershey, PA USA
[3] Penn State Hershey Childrens Hosp, Penn State Hershey Coll Med, Penn State Milton S Hershey Med Ctr, Dept Bioengn, Hershey, PA USA
来源
PERFUSION-UK | 2012年 / 27卷 / 06期
关键词
cardiopulmonary bypass; hollow-fiber membrane oxygenators; microemboli; purge line flow; pediatrics; INTEGRATED ARTERIAL FILTERS; MEMBRANE OXYGENATORS;
D O I
10.1177/0267659112453078
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study compared four pediatric cardiopulmonary bypass (CPB) circuits with four different hollow-fiber membrane oxygenators and their specific reservoirs, Capiox RX15,Quadrox-i pediatric, Quadrox-i pediatric with integrated arterial filter (IAF) and KIDS D101, in a simulated CPB circuit identical to that used in the clinical setting at our institution to test their ability to maintain hemodynamic properties, remove gaseous microemboli (GME), and to test the amount of blood "stolen" by the arterial filter purge line. The circuit was first primed with Ringer's Lactate solution, then red blood cells were added and the hematocrit was maintained at 30%. A 5-cc bolus of air was injected just proximal to the venous reservoir over a thirty-second interval and GME were monitored using an Emboli Detection and Classification quantifier. Transducers were placed at pre-oxygenator, post-oxygenator and distal arterial line (post-filter) positions. Flow probes were also placed both pre and post filter. The injections were made at three flow rates, hypothermic and normothermic temperatures, and with the purge line in both the opened and closed positions. Six injections were done at each of the 12 experimental conditions. Results demonstrated that GME in the arterial line increased with increasing temperature and flow rate. The Capiox RX15 had the least GME in the arterial line at all experimental conditions. The KIDS D101 had the largest pressure drop and the lowest retention of hemodynamic energy, while the Capiox had the lowest pressure drop. All of the oxygenators had a similar amount of "stolen" blood flow and it was consistently under 10% of the total flow reaching the patient.
引用
收藏
页码:470 / 479
页数:10
相关论文
共 50 条
  • [41] Hematologic evaluation of cardiopulmonary bypass circuits prepared with a novel block copolymer
    Rubens, FD
    Labow, RS
    Lavallée, GR
    Watson, MI
    Robblee, JA
    Voorhees, ME
    Nathan, HJ
    ANNALS OF THORACIC SURGERY, 1999, 67 (03): : 689 - 696
  • [42] Evaluation of Quadrox-i and Capiox FX neonatal oxygenators with integrated arterial filters in eliminating gaseous microemboli and retaining hemodynamic properties during simulated cardiopulmonary bypass
    Lin, J.
    Dogal, N. M.
    Mathis, R. K.
    Qiu, F.
    Kunselman, A.
    Uendar, A.
    PERFUSION-UK, 2012, 27 (03): : 235 - 243
  • [43] Performance Evaluation of Geometrically Different Pediatric Arterial Cannulae in a Pediatric Cardiopulmonary Bypass Model
    de O. Carvalho, Gabriela B.
    Caneo, Luiz Fernando
    Matte, Gregory
    de A. Cruz, Caio Henrique
    da Silva, Everton Neri
    Carletto, Luciana P.
    de Castro, Ana Vitoria C. X.
    Silva, Betina G. Madueno
    Policarpo, Valeria C.
    Cestari, Idagene A.
    Jatene, Fabio B.
    Jatene, Marcelo Biscegli
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2024, 39 (01)
  • [44] Usefulness of continuous air tonometry for evaluation of splanchnic perfusion during cardiopulmonary bypass
    Masai, T
    Taniguchi, K
    Kuki, S
    Yokota, T
    Yoshida, K
    Yamamoto, K
    Matsuda, H
    ASAIO JOURNAL, 2003, 49 (01) : 108 - 111
  • [45] Functional Performance of Different Venous Limb Options in Simulated Neonatal/Pediatric Cardiopulmonary Bypass Circuits
    Caneo, Luiz Fernando
    Matte, Gregory S.
    Guimaraes, Daniel Peres
    Viotto, Guilherme
    Mazzeto, Marcelo
    Cestari, Idagene
    Neirotti, Rodolfo A.
    Jatene, Marcelo B.
    Wang, Shigang
    Undar, Akif
    Chang Junior, Joao
    Jatene, Fabio B.
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2018, 33 (03) : 224 - 232
  • [46] Hematologic evaluation of cardiopulmonary bypass circuits prepared with a novel block copolymer - Invited commentary
    Edmunds, LH
    ANNALS OF THORACIC SURGERY, 1999, 67 (03): : 696 - 697
  • [47] Microemboli detection and classification by innovative ultrasound technology during simulated neonatal cardiopulmonary bypass at different flow rates, perfusion modes, and perfusate temperatures
    Schreiner, Robert S.
    Rider, Alan R.
    Myers, John W.
    Ji, Bingyang
    Kunselman, Allen R.
    Myers, John L.
    Uendar, Akif
    ASAIO JOURNAL, 2008, 54 (03) : 316 - 324
  • [48] Comparison of four different pediatric 10F aortic cannulae during Pulsatile versus nonpulsatile perfusion in a simulated neonatal model of cardiopulmonary bypass
    Uendar, Akif
    Ji, Bingyang
    Rider, Alan
    Lukic, Branka
    Kunselman, Allen R.
    Weiss, William J.
    Myers, John L.
    ASAIO JOURNAL, 2007, 53 (06) : 778 - 784
  • [49] An approach towards total quality assurance in cardiopulmonary bypass: which data to register and how to assess perfusion quality
    Pedersen, Claus
    Kaarsen, Annette Lowenmark
    Benze, Sylvia
    PERFUSION-UK, 1996, 11 (01): : 39 - 44
  • [50] Improved Cerebral Oxygen Saturation and Blood Flow Pulsatility With Pulsatile Perfusion During Pediatric Cardiopulmonary Bypass
    Xiaowei W Su
    Yulong Guan
    Mollie Barnes
    J Brian Clark
    John L Myers
    Akif Ündar
    Pediatric Research, 2011, 70 : 181 - 185