Evaluation of four pediatric cardiopulmonary bypass circuits in terms of perfusion quality and capturing gaseous microemboli

被引:14
|
作者
Mathis, R. K. [1 ]
Lin, J. [1 ]
Dogal, N. M. [1 ]
Qiu, F. [1 ]
Kunselman, A.
Wang, S. [1 ]
Uendar, A. [1 ,2 ,3 ]
机构
[1] Penn State Hershey Childrens Hosp, Penn State Hershey Coll Med, Penn State Milton S Hershey Med Ctr, Penn State Hershey Pediat Cardiovasc Res Ctr,Dept, Hershey, PA USA
[2] Penn State Hershey Childrens Hosp, Penn State Hershey Coll Med, Penn State Milton S Hershey Med Ctr, Dept Surg, Hershey, PA USA
[3] Penn State Hershey Childrens Hosp, Penn State Hershey Coll Med, Penn State Milton S Hershey Med Ctr, Dept Bioengn, Hershey, PA USA
来源
PERFUSION-UK | 2012年 / 27卷 / 06期
关键词
cardiopulmonary bypass; hollow-fiber membrane oxygenators; microemboli; purge line flow; pediatrics; INTEGRATED ARTERIAL FILTERS; MEMBRANE OXYGENATORS;
D O I
10.1177/0267659112453078
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study compared four pediatric cardiopulmonary bypass (CPB) circuits with four different hollow-fiber membrane oxygenators and their specific reservoirs, Capiox RX15,Quadrox-i pediatric, Quadrox-i pediatric with integrated arterial filter (IAF) and KIDS D101, in a simulated CPB circuit identical to that used in the clinical setting at our institution to test their ability to maintain hemodynamic properties, remove gaseous microemboli (GME), and to test the amount of blood "stolen" by the arterial filter purge line. The circuit was first primed with Ringer's Lactate solution, then red blood cells were added and the hematocrit was maintained at 30%. A 5-cc bolus of air was injected just proximal to the venous reservoir over a thirty-second interval and GME were monitored using an Emboli Detection and Classification quantifier. Transducers were placed at pre-oxygenator, post-oxygenator and distal arterial line (post-filter) positions. Flow probes were also placed both pre and post filter. The injections were made at three flow rates, hypothermic and normothermic temperatures, and with the purge line in both the opened and closed positions. Six injections were done at each of the 12 experimental conditions. Results demonstrated that GME in the arterial line increased with increasing temperature and flow rate. The Capiox RX15 had the least GME in the arterial line at all experimental conditions. The KIDS D101 had the largest pressure drop and the lowest retention of hemodynamic energy, while the Capiox had the lowest pressure drop. All of the oxygenators had a similar amount of "stolen" blood flow and it was consistently under 10% of the total flow reaching the patient.
引用
收藏
页码:470 / 479
页数:10
相关论文
共 50 条
  • [21] RETROGRADE PERFUSION OF CORONARY ARTERIES WITH GASEOUS OXYGEN DURING CARDIOPULMONARY BYPASS
    CAMISHION, RC
    DAVIES, AL
    TOKUNAGA, K
    SOLIT, RW
    SURGERY, 1966, 59 (01) : 145 - +
  • [22] Evaluation of HL-20 Roller Pump and Rotaflow Centrifugal Pump on Perfusion Quality and Gaseous Microemboli Delivery
    Yee, Stella
    Qiu, Feng
    Su, Xiaowei
    Rider, Alan
    Kunselman, Allen R.
    Guan, Yulong
    Uendar, Akif
    ARTIFICIAL ORGANS, 2010, 34 (11) : 937 - 943
  • [23] Do surface modifying additives (SMA) in cardiopulmonary bypass circuits reduce the number of brain microemboli?
    Deal, DD
    Brown, WR
    Moody, DM
    Vernon, JC
    Miller, MJ
    Stump, DA
    ANESTHESIOLOGY, 1998, 89 (3A) : U466 - U466
  • [24] Gaseous microemboli in cardiac surgery with cardiopulmonary bypass: the use of veno-arterial shunt as a preventive method
    dos Reis, Edison Emidio
    de Menezes, Livia Dutra
    Lanaro Justo, Caio Cesar
    REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR, 2012, 27 (03): : 436 - 445
  • [25] THE EFFECT OF ARTERIAL FILTRATION ON REDUCTION OF GASEOUS MICROEMBOLI IN THE MIDDLE CEREBRAL-ARTERY DURING CARDIOPULMONARY BYPASS
    PADAYACHEE, TS
    PARSONS, S
    THEOBOLD, R
    GOSLING, RG
    DEVERALL, PB
    ANNALS OF THORACIC SURGERY, 1988, 45 (06): : 647 - 649
  • [26] In-Vitro Evaluation of Two Types of Neonatal Oxygenators in Handling Gaseous Microemboli and Maintaining Optimal Hemodynamic Stability During Cardiopulmonary Bypass
    Marupudi, Neelima
    Wang, Shigang
    Caneo, Luiz Fernando
    Jatene, Fabio Biscegli
    Kunselman, Allen R.
    Undar, Akif
    BRAZILIAN JOURNAL OF CARDIOVASCULAR SURGERY, 2016, 31 (05) : 343 - 350
  • [27] Biocompatibility of heparin-coated circuits in pediatric cardiopulmonary bypass
    Kagisaki, K
    Masai, T
    Kadoba, K
    Sawa, Y
    Nomura, F
    Fukushima, N
    Ichikawa, H
    Ohata, T
    Suzuki, K
    Taketani, S
    Matsuda, H
    ARTIFICIAL ORGANS, 1997, 21 (07) : 836 - 840
  • [28] Gaseous Microemboli in the Cardiopulmonary Bypass Circuit: Presentation of a Systematic Data Collection Protocol Applied at Istituto Cardiocentro Ticino
    Puthettu, Mira
    Vandenberghe, Stijn
    Bagnato, Pietro
    Gallo, Michele
    Demertzis, Stefanos
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (02)
  • [29] Effect of pulsatile perfusion during cardiopulmonary bypass in terms of radial artery sphygmogram
    Zhang, Zhifeng
    Xu, Jiatuo
    Zhu, Enyuan
    Zhang, Qi
    Yu, Lu
    Qiu, Yongbing
    Tang, Jianguo
    Fei, Zhaofu
    Li, Xin
    Tu, Liping
    Han, Chouping
    Liu, Ying
    Guo, Zhen
    Zhou, Changle
    Shi, Meiyu
    Qian, Yingxin
    Bao, Yimin
    Ji, Xinming
    JOURNAL OF TRADITIONAL CHINESE MEDICINE, 2014, 34 (06) : 673 - 677
  • [30] Effect of pulsatile perfusion during cardiopulmonary bypass in terms of radial artery sphygmogram
    Zhifeng Zhang
    Jiatuo Xu
    Enyuan Zhu
    Qi Zhang
    Lu Yu
    Yongbing Qiu
    Jianguo Tang
    Zhaofu Fei
    Xin Li
    Liping Tu
    Chouping Han
    Ying Liu
    Zhen Guo
    Changle Zhou
    Meiyu Shi
    Yingxin Qian
    Yimin Bao
    Xinming Ji
    Journal of Traditional Chinese Medicine, 2014, 34 (06) : 673 - 677