Evaluation of four pediatric cardiopulmonary bypass circuits in terms of perfusion quality and capturing gaseous microemboli

被引:14
|
作者
Mathis, R. K. [1 ]
Lin, J. [1 ]
Dogal, N. M. [1 ]
Qiu, F. [1 ]
Kunselman, A.
Wang, S. [1 ]
Uendar, A. [1 ,2 ,3 ]
机构
[1] Penn State Hershey Childrens Hosp, Penn State Hershey Coll Med, Penn State Milton S Hershey Med Ctr, Penn State Hershey Pediat Cardiovasc Res Ctr,Dept, Hershey, PA USA
[2] Penn State Hershey Childrens Hosp, Penn State Hershey Coll Med, Penn State Milton S Hershey Med Ctr, Dept Surg, Hershey, PA USA
[3] Penn State Hershey Childrens Hosp, Penn State Hershey Coll Med, Penn State Milton S Hershey Med Ctr, Dept Bioengn, Hershey, PA USA
来源
PERFUSION-UK | 2012年 / 27卷 / 06期
关键词
cardiopulmonary bypass; hollow-fiber membrane oxygenators; microemboli; purge line flow; pediatrics; INTEGRATED ARTERIAL FILTERS; MEMBRANE OXYGENATORS;
D O I
10.1177/0267659112453078
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This study compared four pediatric cardiopulmonary bypass (CPB) circuits with four different hollow-fiber membrane oxygenators and their specific reservoirs, Capiox RX15,Quadrox-i pediatric, Quadrox-i pediatric with integrated arterial filter (IAF) and KIDS D101, in a simulated CPB circuit identical to that used in the clinical setting at our institution to test their ability to maintain hemodynamic properties, remove gaseous microemboli (GME), and to test the amount of blood "stolen" by the arterial filter purge line. The circuit was first primed with Ringer's Lactate solution, then red blood cells were added and the hematocrit was maintained at 30%. A 5-cc bolus of air was injected just proximal to the venous reservoir over a thirty-second interval and GME were monitored using an Emboli Detection and Classification quantifier. Transducers were placed at pre-oxygenator, post-oxygenator and distal arterial line (post-filter) positions. Flow probes were also placed both pre and post filter. The injections were made at three flow rates, hypothermic and normothermic temperatures, and with the purge line in both the opened and closed positions. Six injections were done at each of the 12 experimental conditions. Results demonstrated that GME in the arterial line increased with increasing temperature and flow rate. The Capiox RX15 had the least GME in the arterial line at all experimental conditions. The KIDS D101 had the largest pressure drop and the lowest retention of hemodynamic energy, while the Capiox had the lowest pressure drop. All of the oxygenators had a similar amount of "stolen" blood flow and it was consistently under 10% of the total flow reaching the patient.
引用
收藏
页码:470 / 479
页数:10
相关论文
共 50 条
  • [31] Evaluation of Different Diameter Arterial Tubing and Arterial Cannulae in Simulated Neonatal/Pediatric Cardiopulmonary Bypass Circuits
    Wang, Shigang
    Rosenthal, Tami
    Kunselman, Allen R.
    Uendar, Akif
    ARTIFICIAL ORGANS, 2015, 39 (01) : 43 - 52
  • [32] A cardiopulmonary bypass score system to assess quality of perfusion performance
    Jegger, D
    Ruchat, P
    Horisberger, J
    Boone, Y
    Pierrel, N
    Seigneuil, I
    von Segesser, LK
    PERFUSION-UK, 2001, 16 (03): : 183 - 188
  • [33] The Effect of Nitric Oxide Supplied to the Sweep Gas of the Oxygenator on the Formation of Gaseous Microemboli during Cardiopulmonary Bypass (Experimental Study)
    Marichev, A. O.
    Radovskiy, A. M.
    Osovskikh, V. V.
    Kozyrev, D. A.
    Chomakhashvili, I. G.
    Lomaev, A. A.
    Sorokina, A. K.
    Chinenkov, I. A.
    Vasilchenko, O. I.
    Avezov, D. A.
    Kalinin, M. O.
    Bautin, A. E.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2024, 177 (06) : 787 - 791
  • [34] Translational Research on Evaluation of Pediatric Cardiopulmonary Bypass Oxygenators
    Undar, Akif
    ARTIFICIAL ORGANS, 2018, 42 (01) : 103 - 103
  • [35] Evaluation of Perfusion Modes on Vital Organ Recovery and Thyroid Hormone Homeostasis in Pediatric Patients Undergoing Cardiopulmonary Bypass
    Akcevin, Atif
    Alkan-Bozkaya, Tijen
    Qiu, Feng
    Uendar, Akif
    ARTIFICIAL ORGANS, 2010, 34 (11) : 879 - 884
  • [36] An evaluation of the benefits of pulsatile versus nonpulsatile perfusion during cardiopulmonary bypass procedures in pediatric and adult cardiac patients
    Ji, Bingyang
    Uendar, Akif
    ASAIO JOURNAL, 2006, 52 (04) : 357 - 361
  • [37] Superior biocompatibility of heparin-bonded circuits in pediatric cardiopulmonary bypass.
    Ozawa T.
    Yoshihara K.
    Koyama N.
    Yamazaki S.
    Takanashi Y.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 1999, 47 (12): : 592 - 599
  • [38] Comparison of six pediatric cardiopulmonary bypass pumps during pulsatile and nonpulsatile perfusion
    Ündar, A
    Eichstaedt, HC
    Masai, T
    Yang, SQ
    Bigley, JE
    McGarry, MC
    Mueller, M
    Vaughn, WK
    Fraser, CD
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 122 (04): : 827 - 829
  • [39] Clinical Application of Pulsatile Perfusion During Cardiopulmonary Bypass In Pediatric Heart Surgery
    Zhao, Ju
    Liu, Jin-Ping
    Feng, Zheng-Yi
    Liu, Ying-Long
    Li, Shou-Jun
    Long, Cun
    ASAIO JOURNAL, 2009, 55 (03) : 300 - 303
  • [40] In Vitro Comparison of the Delivery of Gaseous Microemboli and Hemodynamic Energy for a Diagonal and a Roller Pump During Simulated Infantile Cardiopulmonary Bypass Procedures
    Dhami, Ranjodh
    Wang, Shigang
    Kunselman, Allen R.
    Uendar, Akif
    ARTIFICIAL ORGANS, 2014, 38 (01) : 56 - 63