Influence of high temperature on solid state nuclear track detector parameters

被引:4
|
作者
Malinowska, A. [1 ]
Szydlowski, A. [1 ]
Jaskola, M. [1 ]
Korman, A. [1 ]
机构
[1] Natl Ctr Nucl Res NCBJ, PL-05400 Otwock, Poland
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2012年 / 83卷 / 09期
关键词
SPACE-RESOLVED MEASUREMENTS; FUSION-REACTION PROTONS; PLASMA; DIAGNOSTICS; EMISSION;
D O I
10.1063/1.4750130
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work concerns the influence of high temperatures on tracks induced in solid state nuclear track detectors of the CR-39/PM-355 type. In order to investigate this effect some samples of the detectors were irradiated with energetic protons and alpha particles and subsequently heated under controlled temperatures for different periods of time. After heating the samples were etched and the track evolution was analyzed using an optical microscope. The bulk etch rate V-B of the PM-355 material was also determined as a function of heating temperature. The track etch rate V-T values were estimated for craters induced by protons and alpha particles from track diameter measurement as a function of heating temperature. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4750130]
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Radon alpha track counting on solid state nuclear track detector by an ImageJ-based software macro
    Frutos-Puerto, S.
    Hurtado-Sanchez, M. C.
    de la Torre Perez, J.
    Pinilla-Gil, E.
    Miro, C.
    APPLIED RADIATION AND ISOTOPES, 2021, 173
  • [32] Radon alpha track counting on solid state nuclear track detector by an ImageJ-based software macro
    Frutos-Puerto, S.
    Hurtado-Sanchez, M.C.
    Pérez, J. de la Torre
    Pinilla-Gil, E.
    Miró, C.
    Applied Radiation and Isotopes, 2021, 173
  • [33] Advantages of the use of solid-state nuclear track detectors in high-temperature plasma experiments
    Szydlowski, A
    Banaszak, A
    Sadowski, MJ
    Scholz, M
    Wolowski, J
    RADIATION MEASUREMENTS, 2005, 40 (2-6) : 479 - 482
  • [34] Calibration of a solid state nuclear track detector (SSNTD) with high detection threshold to search for rare events in cosmic rays
    Dey, S.
    Gupta, D.
    Maulik, A.
    Raha, Sibaji
    Saha, Swapan K.
    Syam, D.
    Pakarinen, J.
    Voulot, D.
    Wenander, F.
    ASTROPARTICLE PHYSICS, 2011, 34 (11) : 805 - 808
  • [35] ON THE USE OF POLYETHYLENETEREPHTHALATE AS SOLID-STATE NUCLEAR TRACK DETECTOR - MECHANISM AND KINETICS OF BULK ETCHING
    LUCK, HB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 200 (2-3): : 517 - 523
  • [36] DETERMINATION OF RADIOACTIVE EQUILIBRIUM IN AMANG SAMPLES USING SOLID-STATE NUCLEAR TRACK DETECTOR
    ZAINUDDIN, MJ
    KANDAIYA, S
    HU, SJ
    APPLIED RADIATION AND ISOTOPES, 1987, 38 (02) : 143 - 145
  • [38] DIAGNOSTICS OF HELIUM-IONS COLLECTIVELY ACCELERATED BY A SOLID-STATE NUCLEAR TRACK DETECTOR
    MASUZAKI, M
    KOMORI, S
    NAKANISHI, T
    YOKOI, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1982, 21 (10): : 1523 - 1523
  • [39] Use of CR-39 solid state nuclear track detector in neutron personnel monitoring
    Dhairyawan, MP
    Marathe, PK
    Massand, OP
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 435 - 438
  • [40] Fluorescent nuclear track detector technology - A new way to do passive solid state dosimetry
    Akselrod, M. S.
    Sykora, G. J.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1671 - 1679