Influence of high temperature on solid state nuclear track detector parameters

被引:4
|
作者
Malinowska, A. [1 ]
Szydlowski, A. [1 ]
Jaskola, M. [1 ]
Korman, A. [1 ]
机构
[1] Natl Ctr Nucl Res NCBJ, PL-05400 Otwock, Poland
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2012年 / 83卷 / 09期
关键词
SPACE-RESOLVED MEASUREMENTS; FUSION-REACTION PROTONS; PLASMA; DIAGNOSTICS; EMISSION;
D O I
10.1063/1.4750130
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work concerns the influence of high temperatures on tracks induced in solid state nuclear track detectors of the CR-39/PM-355 type. In order to investigate this effect some samples of the detectors were irradiated with energetic protons and alpha particles and subsequently heated under controlled temperatures for different periods of time. After heating the samples were etched and the track evolution was analyzed using an optical microscope. The bulk etch rate V-B of the PM-355 material was also determined as a function of heating temperature. The track etch rate V-T values were estimated for craters induced by protons and alpha particles from track diameter measurement as a function of heating temperature. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4750130]
引用
收藏
页数:4
相关论文
共 50 条
  • [41] THE LOW VELOCITY RESPONSE OF THE SOLID-STATE NUCLEAR TRACK DETECTOR CR-39
    SNOWDENIFFT, DP
    PRICE, PB
    PHYSICS LETTERS B, 1992, 288 (3-4) : 250 - 253
  • [42] Charge Particle Spectroscopy: A Solid-State Nuclear Track Detector (SSNTD)-Based Spectrometer
    Nidal Dwaikat
    Arabian Journal for Science and Engineering, 2024, 49 : 1237 - 1243
  • [43] Study of indoor radon levels in Garhwal Himalayas using solid state nuclear track detector
    Ramola, RC
    RADON AND THORON IN THE HUMAN ENVIRONMENT, 1998, : 367 - 372
  • [44] INDOOR RN-222 MEASUREMENTS IN SWAZILAND WITH THE SOLID-STATE NUCLEAR TRACK DETECTOR
    MAHLOBO, M
    NSIBANDE, M
    FARID, SM
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1995, 27 (03) : 261 - 268
  • [45] DETERMINATION OF RADIOACTIVE EQUILIBRIUM IN AMANG SAMPLES USING SOLID STATE NUCLEAR TRACK DETECTOR.
    Zainuddin, M.J.
    Kandaiya, S.
    Hu, S.J.
    1600, (38):
  • [46] Fast neutron irradiation effects on CN-85 solid state nuclear track detector
    Nouh, SA
    Hegazy, TM
    RADIATION MEASUREMENTS, 2006, 41 (01) : 17 - 22
  • [47] Study on energy response of a solid state nuclear track detector to neutrons up to 80 MeV
    Nakane, Y
    Sakamoto, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (03): : 348 - 357
  • [48] Study of the neutron radiography characteristics for the solid state nuclear track detector Makrofol-DE
    Pugliesi, R
    Pereira, MAS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3): : 613 - 618
  • [49] QUANTITATIVE-ANALYSIS OF B-10 WITH SOLID-STATE NUCLEAR TRACK DETECTOR
    TSURUTA, T
    KATSURAYAMA, K
    ISHIDA, M
    YAZAKI, M
    KAWAI, H
    MORISHITA, H
    HEALTH PHYSICS, 1977, 33 (02): : 159 - 160
  • [50] ON THE USE OF CELLULOSE NITRATE AS SOLID-STATE NUCLEAR TRACK DETECTOR .1. DETECTOR PREPARATION AND ETCHING BEHAVIOR
    LUCK, HB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 212 (1-3): : 479 - 482