Influence of high temperature on solid state nuclear track detector parameters

被引:4
|
作者
Malinowska, A. [1 ]
Szydlowski, A. [1 ]
Jaskola, M. [1 ]
Korman, A. [1 ]
机构
[1] Natl Ctr Nucl Res NCBJ, PL-05400 Otwock, Poland
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2012年 / 83卷 / 09期
关键词
SPACE-RESOLVED MEASUREMENTS; FUSION-REACTION PROTONS; PLASMA; DIAGNOSTICS; EMISSION;
D O I
10.1063/1.4750130
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work concerns the influence of high temperatures on tracks induced in solid state nuclear track detectors of the CR-39/PM-355 type. In order to investigate this effect some samples of the detectors were irradiated with energetic protons and alpha particles and subsequently heated under controlled temperatures for different periods of time. After heating the samples were etched and the track evolution was analyzed using an optical microscope. The bulk etch rate V-B of the PM-355 material was also determined as a function of heating temperature. The track etch rate V-T values were estimated for craters induced by protons and alpha particles from track diameter measurement as a function of heating temperature. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4750130]
引用
收藏
页数:4
相关论文
共 50 条
  • [21] THE EFFECT OF THE MATERIAL HOMOGENEITY ON THE RESPONSE OF THE SOLID-STATE NUCLEAR TRACK DETECTOR
    CHARVAT, J
    KOPECKA, B
    KERNENERGIE, 1991, 34 (7-8): : 300 - 302
  • [22] Application of solid state nuclear track detector in accelerator driven clean nuclear power system
    Shi, Yongqian
    Li, Yiguo
    Xia, Pu
    Luo, Zhanglin
    He Jishu/Nuclear Techniques, 2002, 25 (07):
  • [23] ON THE USE OF POLYETHYLENETEREPHTHALATE AS SOLID-STATE NUCLEAR TRACK DETECTOR - KINETICS AND MECHANISM OF PARTICLE TRACK ETCHING
    LUCK, HB
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 213 (2-3): : 507 - 511
  • [24] APPLICATION OF SOLID-STATE NUCLEAR TRACK DETECTORS TO HURST THRESHOLD DETECTOR SYSTEM
    KERR, GD
    STRICKLER, TD
    HEALTH PHYSICS, 1966, 12 (08): : 1141 - +
  • [25] EVIDENCE OF A NEW TYPE OF FISSION WITHIN A SOLID-STATE NUCLEAR TRACK DETECTOR
    DEBEAUVAIS, M
    RALAROSY, J
    TRIPIER, J
    JOKIC, S
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE II, 1982, 294 (18): : 1115 - 1118
  • [26] URANIUM ESTIMATION IN MUSSOORIE PHOSPHORITES USING SOLID-STATE NUCLEAR TRACK DETECTOR
    SINGH, S
    VIRK, HS
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1983, 21 (02) : 125 - 126
  • [27] Calibration of solid state nuclear track detector CR-39 with monoenergetic protons
    Duan Xiao-Jiao
    Tan Zhi-Xin
    Lan Xiao-Fei
    Huang Yong-Sheng
    Guo Shi-Lun
    Yang Da-Wei
    Tang Xiu-Zhang
    Wang Nai-Yan
    ACTA PHYSICA SINICA, 2010, 59 (05) : 3147 - 3153
  • [28] Evaluation of solid state nuclear track detector stacks exposed on the international space station
    Pálfalvi, JK
    Akatov, Y
    Szabó, J
    Sajó-Bohus, L
    Eördögh, I
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 393 - 397
  • [29] Study of heavy ion range in different solid state nuclear track detector materials
    Diwan, PK
    Singh, L
    Singh, G
    Kumar, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2000, 160 (04): : 449 - 452
  • [30] Solid state nuclear track detectors
    Virk, HS
    CURRENT SCIENCE, 2002, 82 (03): : 254 - 254