Evaluation of solid state nuclear track detector stacks exposed on the international space station

被引:15
|
作者
Pálfalvi, JK
Akatov, Y
Szabó, J
Sajó-Bohus, L
Eördögh, I
机构
[1] KFKI, Atom Energy Res Inst, H-1525 Budapest, Hungary
[2] Inst Biomed Problems, Moscow 123007, Russia
[3] Univ Simon Bolivar, Caracas 89000, Venezuela
[4] Res Inst TEch Phys & Mat Sci, H-1525 Budapest, Hungary
关键词
D O I
10.1093/rpd/nch140
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of the study was to investigate the contribution of secondary neutrons to the total dose inside the International Space Station (ISS). For this purpose solid-state nuclear track detector (SSNTD) stacks were used. Each stack consisted of three CR-39 sheets. The first and second sheets were separated by a Ti plate, and the second and third sheets sandwiched a Lexan polycarbonate foil. The neutron and proton responses of each sheet were studied through MC calculations and experimentally, utilising monoenergetic protons. Seven stacks were exposed in 2001 for 249 days at different locations of the Russian segment 'Zvezda'. The total storage time before and after the exposure onboard was estimated to be seven months. Another eight stacks were exposed at the CERF high-energy neutron field for calibration purposes. The CR-39 detectors were evaluated in four steps: after 2, 6, 12 and 20 h etching in 6 N NaOH at 70 degreesC (V-B = 1.34 mum h(-1)). All the individual tracks were investigated and recorded using an image analyser. The stacks provided the averaged neutron ambient dose equivalent (H*) between 200 keV and 20 MeV, and the values varied from 39 to 73 muSv d(-1), depending on the location. The Lexan detectors were used to detect the dose originating from high-charge and high-energy (HZE) particles. These results will be published elsewhere.
引用
收藏
页码:393 / 397
页数:5
相关论文
共 50 条
  • [1] ANOMALOUS NUCLEAR PHENOMENA AND SOLID-STATE NUCLEAR TRACK DETECTOR
    LI, XZ
    MO, DW
    ZHANG, L
    WANG, SC
    KANG, TS
    LIU, SJ
    WANG, J
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 599 - 604
  • [2] Studying the physical parameters of a solid state nuclear track detector
    Nabil M. Hassan
    Abdel Fattah Hafez
    Journal of the Korean Physical Society, 2013, 63 : 1713 - 1719
  • [3] Studying the Physical Parameters of a Solid State Nuclear Track Detector
    Hassan, Nabil M.
    Hafez, Abdel Fattah
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (09) : 1713 - 1719
  • [4] Calibration of CR-39 solid state nuclear track detector
    P. Wanabongse
    B. Sola
    J. Jamsangtong
    S. Rattanabussayaporn
    Indian Journal of Physics, 2009, 83 : 833 - 837
  • [5] Modelling of solid state nuclear track detector devices for radon measurements
    Andriamanatena, R
    Bacmeister, GU
    Freyer, K
    Ghose, R
    Jonsson, G
    Kleis, T
    Treutler, HC
    Enge, W
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 657 - 662
  • [6] APPLICATION OF SOLID-STATE NUCLEAR TRACK DETECTOR IN NEUTRON DOSIMETRY
    LI, HT
    ZHU, TC
    XIE, YR
    XIE, JL
    DEXI, J
    HUANG, CG
    XU, SK
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1981, 5 (04): : 371 - 372
  • [7] Influence of high temperature on solid state nuclear track detector parameters
    Malinowska, A.
    Szydlowski, A.
    Jaskola, M.
    Korman, A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (09):
  • [8] Calibration of solid state nuclear track detector CR-39
    Ren, GX
    Jing, GR
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (06): : 596 - 598
  • [9] Radiation effect on positronium formation in solid state nuclear track detector
    Mohamed, Hamdy F. M.
    El-Hady, M. Abd
    Abdel-Hady, E. E.
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (03) : 328 - 334
  • [10] SOLID-STATE NUCLEAR TRACK DETECTOR APPLICATION TO BIOLOGIC RADIOAUTOGRAPHY
    ESCHENBR.AB
    FEDERATION PROCEEDINGS, 1969, 28 (02) : 295 - &