Influence of high temperature on solid state nuclear track detector parameters

被引:4
|
作者
Malinowska, A. [1 ]
Szydlowski, A. [1 ]
Jaskola, M. [1 ]
Korman, A. [1 ]
机构
[1] Natl Ctr Nucl Res NCBJ, PL-05400 Otwock, Poland
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2012年 / 83卷 / 09期
关键词
SPACE-RESOLVED MEASUREMENTS; FUSION-REACTION PROTONS; PLASMA; DIAGNOSTICS; EMISSION;
D O I
10.1063/1.4750130
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This work concerns the influence of high temperatures on tracks induced in solid state nuclear track detectors of the CR-39/PM-355 type. In order to investigate this effect some samples of the detectors were irradiated with energetic protons and alpha particles and subsequently heated under controlled temperatures for different periods of time. After heating the samples were etched and the track evolution was analyzed using an optical microscope. The bulk etch rate V-B of the PM-355 material was also determined as a function of heating temperature. The track etch rate V-T values were estimated for craters induced by protons and alpha particles from track diameter measurement as a function of heating temperature. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4750130]
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Studying the physical parameters of a solid state nuclear track detector
    Nabil M. Hassan
    Abdel Fattah Hafez
    Journal of the Korean Physical Society, 2013, 63 : 1713 - 1719
  • [2] Studying the Physical Parameters of a Solid State Nuclear Track Detector
    Hassan, Nabil M.
    Hafez, Abdel Fattah
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (09) : 1713 - 1719
  • [3] Correlations between track parameters in a solid-state nuclear track detector and its diffraction pattern
    Stevanovic, N.
    Markovic, V. M.
    Milosevic, M.
    Djurdjevic, A.
    Stajic, J. M.
    Milenkovic, B.
    Nikezic, D.
    RADIATION PHYSICS AND CHEMISTRY, 2022, 193
  • [4] ANOMALOUS NUCLEAR PHENOMENA AND SOLID-STATE NUCLEAR TRACK DETECTOR
    LI, XZ
    MO, DW
    ZHANG, L
    WANG, SC
    KANG, TS
    LIU, SJ
    WANG, J
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 599 - 604
  • [5] Calibration of CR-39 solid state nuclear track detector
    P. Wanabongse
    B. Sola
    J. Jamsangtong
    S. Rattanabussayaporn
    Indian Journal of Physics, 2009, 83 : 833 - 837
  • [6] Modelling of solid state nuclear track detector devices for radon measurements
    Andriamanatena, R
    Bacmeister, GU
    Freyer, K
    Ghose, R
    Jonsson, G
    Kleis, T
    Treutler, HC
    Enge, W
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 657 - 662
  • [7] APPLICATION OF SOLID-STATE NUCLEAR TRACK DETECTOR IN NEUTRON DOSIMETRY
    LI, HT
    ZHU, TC
    XIE, YR
    XIE, JL
    DEXI, J
    HUANG, CG
    XU, SK
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1981, 5 (04): : 371 - 372
  • [8] Calibration of solid state nuclear track detector CR-39
    Ren, GX
    Jing, GR
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (06): : 596 - 598
  • [9] Radiation effect on positronium formation in solid state nuclear track detector
    Mohamed, Hamdy F. M.
    El-Hady, M. Abd
    Abdel-Hady, E. E.
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (03) : 328 - 334
  • [10] SOLID-STATE NUCLEAR TRACK DETECTOR APPLICATION TO BIOLOGIC RADIOAUTOGRAPHY
    ESCHENBR.AB
    FEDERATION PROCEEDINGS, 1969, 28 (02) : 295 - &