Modelling of solid state nuclear track detector devices for radon measurements

被引:13
|
作者
Andriamanatena, R
Bacmeister, GU
Freyer, K
Ghose, R
Jonsson, G
Kleis, T
Treutler, HC
Enge, W
机构
[1] Univ Kiel, Inst Reine & Angew Kernphys, D-24118 Kiel, Germany
[2] Univ Autonoma Barcelona, Dept Fis, Bellaterra 089193, Spain
[3] UFZ Helmholtz Ctr Environm Res, Sekt Analyt, D-04318 Leipzig, Germany
[4] Lund Inst Technol, S-22100 Lund, Sweden
关键词
LR-115; track etching rate; bulk etching rate; radon measurements; EU-project;
D O I
10.1016/S1350-4487(97)00159-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Theoretical analytical calculations of the radon registration have been performed for the solid state nuclear track detectors (SSNTD) LR-115 Type II (peliculable) produced by Kodak-Pathe (France). Known and measured properties of LR-115 together with the well established etching theory using "Huygens' principle" were used to carry out these detailed calculations for different types of exposure devices for indoor room and outdoor soil measurements. The results of these modeling calculations are compared with experimental calibration measurements and show good agreement.
引用
收藏
页码:657 / 662
页数:6
相关论文
共 50 条
  • [1] The calibration of the solid state nuclear track detector LR 115 for radon measurements
    Gericke, C
    Ghose, R
    Jönsson, G
    Freyer, K
    Treutler, HC
    Enge, W
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 363 - 366
  • [2] Automating radon solid state track detector measurements
    Fairchild, Robert
    Tjong, Lydiawati
    Wright, Tracy
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1773 - 1777
  • [3] Are solid state nuclear track detectors truly integrated devices?-experimental evidence in radon measurements
    Wasikiewicz, Jaroslaw M.
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (06) : 617 - 622
  • [4] The nuclear track detector - A tool in radon measurements
    Jonsson, G
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 695 - 698
  • [5] Nuclear track detector - a tool in radon measurements
    Univ of Lund, Lund, Sweden
    Radiat Meas, 1-6 (695-698):
  • [6] Measurement of Radon exhalation rate using Solid State Nuclear Track Detector
    Singh, Lalit Mohan
    Singh, K. Y.
    Mahur, Ajay
    Kumar, Dinesh
    Gupta, Devesh
    ADVANCES IN BASIC SCIENCES (ICABS 2019), 2019, 2142
  • [7] Comparison of radon measurements done by solid state nuclear track detectors and electronic devices in the framework of an EU-radon project
    Jonsson, G
    Albarracin, D
    Bacmeister, GU
    Baixeras, C
    Climent, H
    Cotellessa, G
    Devantier, R
    Enge, W
    Freyer, K
    Font, LL
    Ghose, R
    Monnin, MM
    Sciocchetti, G
    Seidel, JL
    Treutler, HC
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 651 - 656
  • [8] SOLID-STATE NUCLEAR TRACK DETECTORS IN RADON MEASUREMENTS INDOORS AND IN THE SOIL
    JONSSON, G
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 335 - 338
  • [9] Radon alpha track counting on solid state nuclear track detector by an ImageJ-based software macro
    Frutos-Puerto, S.
    Hurtado-Sanchez, M. C.
    de la Torre Perez, J.
    Pinilla-Gil, E.
    Miro, C.
    APPLIED RADIATION AND ISOTOPES, 2021, 173
  • [10] Radon alpha track counting on solid state nuclear track detector by an ImageJ-based software macro
    Frutos-Puerto, S.
    Hurtado-Sanchez, M.C.
    Pérez, J. de la Torre
    Pinilla-Gil, E.
    Miró, C.
    Applied Radiation and Isotopes, 2021, 173