Evaluation of solid state nuclear track detector stacks exposed on the international space station

被引:15
|
作者
Pálfalvi, JK
Akatov, Y
Szabó, J
Sajó-Bohus, L
Eördögh, I
机构
[1] KFKI, Atom Energy Res Inst, H-1525 Budapest, Hungary
[2] Inst Biomed Problems, Moscow 123007, Russia
[3] Univ Simon Bolivar, Caracas 89000, Venezuela
[4] Res Inst TEch Phys & Mat Sci, H-1525 Budapest, Hungary
关键词
D O I
10.1093/rpd/nch140
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of the study was to investigate the contribution of secondary neutrons to the total dose inside the International Space Station (ISS). For this purpose solid-state nuclear track detector (SSNTD) stacks were used. Each stack consisted of three CR-39 sheets. The first and second sheets were separated by a Ti plate, and the second and third sheets sandwiched a Lexan polycarbonate foil. The neutron and proton responses of each sheet were studied through MC calculations and experimentally, utilising monoenergetic protons. Seven stacks were exposed in 2001 for 249 days at different locations of the Russian segment 'Zvezda'. The total storage time before and after the exposure onboard was estimated to be seven months. Another eight stacks were exposed at the CERF high-energy neutron field for calibration purposes. The CR-39 detectors were evaluated in four steps: after 2, 6, 12 and 20 h etching in 6 N NaOH at 70 degreesC (V-B = 1.34 mum h(-1)). All the individual tracks were investigated and recorded using an image analyser. The stacks provided the averaged neutron ambient dose equivalent (H*) between 200 keV and 20 MeV, and the values varied from 39 to 73 muSv d(-1), depending on the location. The Lexan detectors were used to detect the dose originating from high-charge and high-energy (HZE) particles. These results will be published elsewhere.
引用
收藏
页码:393 / 397
页数:5
相关论文
共 50 条
  • [41] Use of CR-39 solid state nuclear track detector in neutron personnel monitoring
    Dhairyawan, MP
    Marathe, PK
    Massand, OP
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 435 - 438
  • [42] THE LOW VELOCITY RESPONSE OF THE SOLID-STATE NUCLEAR TRACK DETECTOR CR-39
    SNOWDENIFFT, DP
    PRICE, PB
    PHYSICS LETTERS B, 1992, 288 (3-4) : 250 - 253
  • [43] Charge Particle Spectroscopy: A Solid-State Nuclear Track Detector (SSNTD)-Based Spectrometer
    Nidal Dwaikat
    Arabian Journal for Science and Engineering, 2024, 49 : 1237 - 1243
  • [44] Study of indoor radon levels in Garhwal Himalayas using solid state nuclear track detector
    Ramola, RC
    RADON AND THORON IN THE HUMAN ENVIRONMENT, 1998, : 367 - 372
  • [45] INDOOR RN-222 MEASUREMENTS IN SWAZILAND WITH THE SOLID-STATE NUCLEAR TRACK DETECTOR
    MAHLOBO, M
    NSIBANDE, M
    FARID, SM
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1995, 27 (03) : 261 - 268
  • [46] DETERMINATION OF RADIOACTIVE EQUILIBRIUM IN AMANG SAMPLES USING SOLID STATE NUCLEAR TRACK DETECTOR.
    Zainuddin, M.J.
    Kandaiya, S.
    Hu, S.J.
    1600, (38):
  • [47] Fast neutron irradiation effects on CN-85 solid state nuclear track detector
    Nouh, SA
    Hegazy, TM
    RADIATION MEASUREMENTS, 2006, 41 (01) : 17 - 22
  • [48] Study on energy response of a solid state nuclear track detector to neutrons up to 80 MeV
    Nakane, Y
    Sakamoto, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (03): : 348 - 357
  • [49] Study of the neutron radiography characteristics for the solid state nuclear track detector Makrofol-DE
    Pugliesi, R
    Pereira, MAS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3): : 613 - 618
  • [50] QUANTITATIVE-ANALYSIS OF B-10 WITH SOLID-STATE NUCLEAR TRACK DETECTOR
    TSURUTA, T
    KATSURAYAMA, K
    ISHIDA, M
    YAZAKI, M
    KAWAI, H
    MORISHITA, H
    HEALTH PHYSICS, 1977, 33 (02): : 159 - 160