Use of CR-39 solid state nuclear track detector in neutron personnel monitoring

被引:20
|
作者
Dhairyawan, MP [1 ]
Marathe, PK [1 ]
Massand, OP [1 ]
机构
[1] Bhabha Atom Res Ctr, Personnel Monitoring Sect, Bombay 400094, Maharashtra, India
关键词
neutron monitoring; detectors; CR-39; SSNTD; dose estimation;
D O I
10.1016/S1350-4487(03)00166-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Neutron sources like Am-241-Be, Pu-239-Be, Cf-252 and 14.6 MeV neutron generator arc being used in oil exploration industries as well as in research institutions. While handling these neutron sources, personnel may be exposed to neutrons. Also personnel working in reactors, accelerators may receive dose from neutrons. These exposed individuals need to be monitored regularly for measurement of neutron doses. The individual neutron doses can be estimated by using Kodak NTA films and CR-39 Solid State Nuclear Track Detector with a polyethylene radiator to increase sensitivity in front in holder. Nearly 1450 personnel are being monitored regularly throughout the country on a quarterly basis. In India, the monitoring system adopted for individual neutron dose estimation having energy from 100 keV and above is described in this paper. Background counts of 0.20 mSv could be measured with CR-39 SSNTD foil system and it has been successfully introduced for Fast Neutron Personnel Monitoring for the country. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:435 / 438
页数:4
相关论文
共 50 条
  • [1] Calibration of CR-39 solid state nuclear track detector
    P. Wanabongse
    B. Sola
    J. Jamsangtong
    S. Rattanabussayaporn
    Indian Journal of Physics, 2009, 83 : 833 - 837
  • [2] Calibration of solid state nuclear track detector CR-39
    Ren, GX
    Jing, GR
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (06): : 596 - 598
  • [3] Calibration of CR-39 solid state nuclear track detector
    Wanabongse, P.
    Sola, B.
    Jamsangtong, J.
    Rattanabussayaporn, S.
    INDIAN JOURNAL OF PHYSICS, 2009, 83 (06) : 833 - 837
  • [4] A REVIEW OF THE USE OF CR-39 TRACK DETECTOR IN PERSONNEL NEUTRON DOSIMETRY AND SPECTROMETRY
    MATIULLAH
    AHMAD, N
    DURRANI, SA
    KUDO, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 51 (01): : 76 - 84
  • [5] Photo-Neutron Detection Using Cr-39 Solid State Nuclear Track Detector
    Rajesh, K. R.
    Musthafa, M. M.
    Midhun, C. V.
    Naiby, Joseph
    Raman, R. Ganapathi
    PROF. DINESH VARSHNEY MEMORIAL NATIONAL CONFERENCE ON PHYSICS AND CHEMISTRY OF MATERIALS (NCPCM 2018), 2019, 2100
  • [6] Calibration of solid state nuclear track detector CR-39 with monoenergetic protons
    Duan Xiao-Jiao
    Tan Zhi-Xin
    Lan Xiao-Fei
    Huang Yong-Sheng
    Guo Shi-Lun
    Yang Da-Wei
    Tang Xiu-Zhang
    Wang Nai-Yan
    ACTA PHYSICA SINICA, 2010, 59 (05) : 3147 - 3153
  • [7] Characteristics of the solid state nuclear detector CR-39 for neutron radiography purposes
    Pugliesi, R
    Pereira, MAS
    de Moraes, MAPV
    de Menezes, MO
    APPLIED RADIATION AND ISOTOPES, 1999, 50 (02) : 375 - 380
  • [8] FAST-NEUTRON DOSIMETRY WITH SOLID-STATE TRACK DETECTOR CR-39
    TSURUTA, T
    JUTO, N
    FUKUMOTO, Y
    HEALTH PHYSICS, 1983, 44 (03): : 289 - 289
  • [9] THE LOW VELOCITY RESPONSE OF THE SOLID-STATE NUCLEAR TRACK DETECTOR CR-39
    SNOWDENIFFT, DP
    PRICE, PB
    PHYSICS LETTERS B, 1992, 288 (3-4) : 250 - 253
  • [10] NEUTRON MICRODOSIMETRY UTILIZING CR-39 SOLID-STATE NUCLEAR TRACK DETECTORS
    STAFFORD, PM
    ALMOND, PR
    HORTON, J
    MEDICAL PHYSICS, 1985, 12 (04) : 545 - 545