Use of CR-39 solid state nuclear track detector in neutron personnel monitoring

被引:20
|
作者
Dhairyawan, MP [1 ]
Marathe, PK [1 ]
Massand, OP [1 ]
机构
[1] Bhabha Atom Res Ctr, Personnel Monitoring Sect, Bombay 400094, Maharashtra, India
关键词
neutron monitoring; detectors; CR-39; SSNTD; dose estimation;
D O I
10.1016/S1350-4487(03)00166-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Neutron sources like Am-241-Be, Pu-239-Be, Cf-252 and 14.6 MeV neutron generator arc being used in oil exploration industries as well as in research institutions. While handling these neutron sources, personnel may be exposed to neutrons. Also personnel working in reactors, accelerators may receive dose from neutrons. These exposed individuals need to be monitored regularly for measurement of neutron doses. The individual neutron doses can be estimated by using Kodak NTA films and CR-39 Solid State Nuclear Track Detector with a polyethylene radiator to increase sensitivity in front in holder. Nearly 1450 personnel are being monitored regularly throughout the country on a quarterly basis. In India, the monitoring system adopted for individual neutron dose estimation having energy from 100 keV and above is described in this paper. Background counts of 0.20 mSv could be measured with CR-39 SSNTD foil system and it has been successfully introduced for Fast Neutron Personnel Monitoring for the country. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:435 / 438
页数:4
相关论文
共 50 条
  • [31] APPLICATION OF CR-39 TRACK DETECTOR TO NEUTRON-SPECTRUM MEASUREMENT
    ODA, K
    ENCHO, H
    YONEDA, H
    MIYAKE, H
    URABE, I
    KOBAYASHI, K
    KIMURA, I
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1991, 28 (07) : 608 - 617
  • [32] An approach to nuclear charge identification with CR-39 polymeric nuclear track detector
    Hafez, AF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 122 (01): : 133 - 140
  • [33] Optical density of the etched α-tracks in CR-39 nuclear track detector
    El Hofy, M
    Elsamman, H
    RADIATION MEASUREMENTS, 1998, 29 (05) : 461 - 464
  • [34] STUDY ON THE SENSITIVITY OF SOLID-STATE NUCLEAR TRACK DETECTOR (SSNTD) CR-39 FOR ALPHA-PARTICLES REGISTRATION
    GABER, M
    ELKHIER, AAA
    FAHMI, NM
    ISOTOPENPRAXIS, 1991, 27 (07): : 346 - 349
  • [35] Deep learning-based alpha particles spectroscopy with solid-state nuclear track detector CR-39
    Amit, G.
    Guy-Ron, N.
    Even-Chen, O.
    Yitzhak, N. M.
    Nissim, N.
    Alimi, R.
    RADIATION MEASUREMENTS, 2024, 179
  • [36] Response of nuclear track detector CR-39 to low energy muons
    Thomas, H. S. P.
    Deas, R. M.
    Kirkham, L. N.
    Dodd, P. M.
    Zemaityte, E.
    Hillier, A. D.
    Neely, D.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2021, 63 (12)
  • [38] RELAXATIONAL BEHAVIOR OF CR-39 POLYCARBONATE USED AS NUCLEAR TRACK DETECTOR
    VANDERSCHUEREN, J
    YIANAKOPOULOS, G
    NIEZETTE, J
    CHATRY, C
    GASIOT, J
    JOURNAL OF APPLIED POLYMER SCIENCE, 1992, 44 (06) : 1027 - 1042
  • [39] Evaluation of the sensitivity function V for registration of α-particles in PADC CR-39 solid state nuclear track detector material
    Hermsdorf, Dietrich
    RADIATION MEASUREMENTS, 2009, 44 (03) : 283 - 288
  • [40] ALPHA-PARTICLE RADIOGRAPHY WITH THE CR-39 NUCLEAR TRACK DETECTOR
    DESOUZA, BA
    CABRAL, SC
    LOPES, RT
    RADIATION MEASUREMENTS, 1995, 24 (02) : 187 - 192