Use of CR-39 solid state nuclear track detector in neutron personnel monitoring

被引:20
|
作者
Dhairyawan, MP [1 ]
Marathe, PK [1 ]
Massand, OP [1 ]
机构
[1] Bhabha Atom Res Ctr, Personnel Monitoring Sect, Bombay 400094, Maharashtra, India
关键词
neutron monitoring; detectors; CR-39; SSNTD; dose estimation;
D O I
10.1016/S1350-4487(03)00166-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Neutron sources like Am-241-Be, Pu-239-Be, Cf-252 and 14.6 MeV neutron generator arc being used in oil exploration industries as well as in research institutions. While handling these neutron sources, personnel may be exposed to neutrons. Also personnel working in reactors, accelerators may receive dose from neutrons. These exposed individuals need to be monitored regularly for measurement of neutron doses. The individual neutron doses can be estimated by using Kodak NTA films and CR-39 Solid State Nuclear Track Detector with a polyethylene radiator to increase sensitivity in front in holder. Nearly 1450 personnel are being monitored regularly throughout the country on a quarterly basis. In India, the monitoring system adopted for individual neutron dose estimation having energy from 100 keV and above is described in this paper. Background counts of 0.20 mSv could be measured with CR-39 SSNTD foil system and it has been successfully introduced for Fast Neutron Personnel Monitoring for the country. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:435 / 438
页数:4
相关论文
共 50 条
  • [21] TRACK FORMATION MECHANISMS IN CR-39 AND THEIR RELEVANCE TO PERSONNEL NEUTRON DOSIMETRY
    PARKHURST, MA
    HADLOCK, DE
    BRACKENBUSH, LW
    HEALTH PHYSICS, 1985, 49 (01): : 142 - 142
  • [22] A study on ionizing emissions from limestone samples using CR-39 solid state nuclear track detector
    Paul, D
    Majumdar, JC
    Ghose, D
    Sastri, RC
    ENVIRONMENTAL GEOCHEMISTRY AND HEALTH, 2002, 24 (04) : 321 - 325
  • [23] A Study on Ionizing Emissions from Limestone Samples using CR-39 Solid State Nuclear Track Detector
    Debasish Paul
    J.C. Majumdar
    Debasis Ghose
    R.C. Sastri
    Environmental Geochemistry and Health, 2002, 24 : 321 - 325
  • [24] Online optical monitor of alpha radiations using a polymeric solid state nuclear track detector CR-39
    Kulkarni, Atul
    Vyas, Chirag K.
    Kim, Hojoong
    Kalsi, Puran C.
    Kim, Taesung
    Manchanda, Vijay
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 161 (01): : 697 - 701
  • [25] The effect of two ultraviolet sources on the etching properties of a solid-state nuclear track detector CR-39
    Dwaikat, Nidal
    Sato, Fuminobu
    Kato, Yushi
    Da, Toshiyuki
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 584 (2-3): : 353 - 357
  • [26] Image Processing Analysis of Nuclear Track Parameters for CR-39 Detector Irradiated by Thermal Neutron
    Al-Jobouri, Hussain A.
    Rajab, Mustafa Y.
    9TH INTERNATIONAL PHYSICS CONFERENCE OF THE BALKAN PHYSICAL UNION (BPU-9), 2016, 1722
  • [27] NEUTRON PERSONNEL DOSIMETRY USING A CR-39 CARBONATE PLASTIC DETECTOR
    GOMAA, MA
    KASIM, SA
    NUCLEAR INSTRUMENTS & METHODS, 1980, 176 (03): : 579 - 582
  • [28] A CR-39 TRACK DOSIMETER FOR ROUTINE INDIVIDUAL NEUTRON MONITORING
    LUSZIKBHADRA, M
    ALBERTS, WG
    DERRICO, F
    DIETZ, E
    GULDBAKKE, S
    MATZKE, M
    RADIATION PROTECTION DOSIMETRY, 1994, 55 (04) : 285 - 293
  • [29] Neutron-irradiation effects on track etching and optical characteristics of CR-39 (DOP) nuclear track detector
    Kalsi, Puran C.
    Agarwal, Chhavi
    JOURNAL OF MATERIALS SCIENCE, 2008, 43 (08) : 2865 - 2868
  • [30] Neutron-irradiation effects on track etching and optical characteristics of CR-39 (DOP) nuclear track detector
    Puran C. Kalsi
    Chhavi Agarwal
    Journal of Materials Science, 2008, 43 : 2865 - 2868