System Architecture of the LabPET Small Animal PET Scanner

被引:32
|
作者
Tetrault, Mare-Andre [1 ]
Viscogliosi, Nicolas [1 ]
Riendeau, Joel [1 ]
Belanger, Francois [1 ]
Michaud, Jean-Baptiste [1 ]
Semmaoui, Hicham [1 ]
Berard, Philippe [2 ]
Lemieux, Francois [1 ]
Arpin, Louis [1 ]
Bergeron, Melanie [2 ]
Cadorette, Jules [2 ]
Pepin, Catherine M. [2 ]
Robert, Ghislain [3 ]
Lepage, Martin D. [3 ]
Lecomte, Roger [2 ]
Fontaine, Rejean [1 ]
机构
[1] Univ Sherbrooke, Dept Elect & Comp Engn, Sherbrooke, PQ J1K 2R1, Canada
[2] Univ Sherbrooke, Dept Med Nucl & Radiobiol, Sherbrooke, PQ J1K 2R1, Canada
[3] Gamma Med Ideas Inc, Sherbrooke, PQ J1K 2R1, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
Positron Emission Tomography (PET);
D O I
10.1109/TNS.2008.2002326
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To address modern molecular imaging requirements, a digital positron emission tomography (PET) scanner for small animals has been developed at Universite de Sherbrooke. Based on individual readout of avalanche photodiodes (APD) coupled to LYSO/LGSO phoswich detectors, the scanner supports up to 4608 channels in a 16.2 cm diameter, 11.25 cm axial field of view with an isotropic similar to 1.2 mm FWHM intrinsic spatial resolution at the center of the field of view. Custom data acquisition boards preprocess and sample APD signals at 45 MHz and compute in real time crystal identification, energy and timing information of detected events at an average sustained rate of up to 1250 raw counts per second per mm(2) (10 000 cps/channel). Real time digital signal analysis also filters out events outside the pre-selected energy window with crystal granularity to eliminate Compton events and electronic noise. Retained events are then merged into a single stream through a real-time sorting tree, at which end prompt and delayed coincidences are extracted. A single Firewire link handles both control and data transfers with a host computer. The LabPET features four data recording modes, giving the user the choice to retain data for research or to minimize file size for high coincidence count rate and imaging purposes. The electronic system also supports time synchronized data insertion for flags such as vital signs used in gated image reconstruction. Aside from data acquisition, hardware can generate live energy and discrimination spectra suitable for fast, automatic channel calibration.
引用
收藏
页码:2546 / 2550
页数:5
相关论文
共 50 条
  • [41] Micropet: A dedicated PET scanner for small animal imaging.
    Cherry, SR
    Shao, Y
    Silverman, RW
    Siegel, S
    Meadors, K
    Mumcuoglu, E
    Young, J
    Jones, WF
    Moyers, C
    Andreaco, M
    Paulus, M
    Binkley, D
    Nutt, R
    Phelps, ME
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 334 - 334
  • [42] Attenuation correction for the NIH ATLAS small animal PET scanner
    Yao, RT
    Seidel, R
    Liow, JS
    Green, MV
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2283 - 2287
  • [43] The ClearPET™ neuro scanner:: A dedicated LSO/LuYAP phoswich small animal PET scanner
    Ziemons, K
    Achten, R
    Auffray, E
    Bauer, A
    Brandenburg, G
    Bruyndonckx, P
    Choi, Y
    Daemen, J
    Dehnhardt, M
    Devroede, O
    Fleischer, M
    Fuss, L
    Heinrichs, U
    Hollendung, A
    Holschbach, M
    Khodaverdi, M
    Kirchner, P
    Kleines, H
    Krieguer, M
    Larue, H
    Lecoq, P
    Leyendecker, M
    Moeller, R
    Morel, C
    Mosset, JB
    Parl, C
    Pietrzyk, U
    Schmitz, J
    Streun, M
    Tavernier, S
    Veggian, M
    Zimmermann, E
    Coenen, HH
    Halling, H
    Sievering, R
    Zilles, K
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2430 - 2433
  • [44] Simultaneous PET/SPECT imaging with the small animal scanner YAP-(S)PET
    Bartoli, Antonietta
    Belcari, Nicola
    Del Guerra, Alberto
    Fabbri, Serena
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3408 - 3413
  • [45] Design and construction of the ClearPET/XPAD small animal PET/CT scanner
    Nicol, S.
    Karkar, S.
    Hemmer, C.
    Dawiec, A.
    Benoit, D.
    Breugnon, P.
    Dinkespiler, B.
    Riviere, F.
    Logier, J. -P.
    Niclas, M.
    Royon, J.
    Meessen, C.
    Cassol, F.
    Clemens, J. -C.
    Bonissent, A.
    Debarbieux, F.
    Vigeolas, E.
    Delpierre, P.
    Morel, C.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3311 - 3314
  • [46] Evaluation of the First Silicon Photomultiplier Matrices for a Small Animal PET Scanner
    Llosa, Gabriela
    Belcari, Nicola
    Bisogni, M. Giuseppina
    Collazuol, Gianmaria
    Del Guerra, Alberto
    Marcatili, Sara
    Barrillon, Pierre
    de la Taille, Christophe
    Bondil-Blin, Sylvie
    Dinu, Nicoleta
    Melchiorri, Mirko
    Tarolli, Alessandro
    Piemonte, Claudio
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2849 - +
  • [47] A combined micro-PET/CT scanner for small animal imaging
    Jan, Meei-Ling
    Ni, Yu-Ching
    Chen, Kuo-Wei
    Liang, Hsing-Ching
    Chuang, Keh-Shih
    Fu, Ying-Kai
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 314 - 318
  • [48] Spatial Resolution and Sensitivity of the Inveon Small-Animal PET Scanner
    Visser, Eric P.
    Disselhorst, Jonathan A.
    Brom, Maarten
    Laverman, Peter
    Gotthardt, Martin
    Oyen, Wim J. G.
    Boerman, Otto C.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (01) : 139 - 147
  • [49] Latest Improvements of the YAP-(S)PET Small Animal Scanner
    Del Guerra, A.
    Bartoli, A.
    Belcari, N.
    Di Domenico, G.
    Cesca, N.
    Moretti, E.
    Sabba, N.
    Zavattini, G.
    Lazzarotti, M.
    Sensi, L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S68 - S68
  • [50] Design study for the ClearPET/XPAD small animal PET/CT scanner
    Khodaverdi, M.
    Nicol, S.
    Loess, J.
    Brunner, F. Cassol
    Karkar, S.
    Morel, C.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4300 - 4302