Characteristics of highly cross-linked polyethylene wear debris in vivo

被引:29
|
作者
Baxter, Ryan M. [1 ]
MacDonald, Daniel W. [1 ]
Kurtz, Steven M. [1 ,3 ]
Steinbeck, Marla J. [1 ,2 ]
机构
[1] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, Philadelphia, PA 19104 USA
[2] Drexel Univ, Coll Drexel Med, Philadelphia, PA 19104 USA
[3] Exponent Inc, Philadelphia, PA USA
关键词
total hip replacementhighly cross-linked polyethyleneosteolysiswear debrisbiological activity; MOLECULAR-WEIGHT POLYETHYLENE; TOTAL HIP-ARTHROPLASTY; FUNCTIONAL BIOLOGICAL-ACTIVITY; CONVENTIONAL POLYETHYLENE; UHMWPE PARTICLES; PERIPROSTHETIC TISSUE; MECHANICAL-PROPERTIES; 5-YEAR EXPERIENCE; GAMMA-RADIATION; EARLY FAILURE;
D O I
10.1002/jbm.b.32902
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Despite the widespread implementation of highly cross-linked polyethylene (HXLPE) liners to reduce the clinical incidence of osteolysis, it is not known if the improved wear resistance will outweigh the inflammatory potential of HXLPE wear debris generated in vivo. Thus, we asked: What are the differences in size, shape, number, and biological activity of polyethylene wear particles obtained from primary total hip arthroplasty revision surgery of conventional polyethylene (CPE) versus remelted or annealed HXLPE liners? Pseudocapsular tissue samples were collected from revision surgery of CPE and HXLPE (annealed and remelted) liners, and digested using nitric acid. The isolated polyethylene wear particles were evaluated using scanning electron microscopy. Tissues from both HXLPE cohorts contained an increased percentage of submicron particles compared to the CPE cohort. However, the total number of particles was lower for both HXLPE cohorts, as a result there was no significant difference in the volume fraction distribution and specific biological activity (SBA; the relative biological activity per unit volume) between cohorts. In contrast, based on the decreased size and number of HXLPE wear debris there was a significant decrease in total particle volume (mm3/g of tissue). Accordingly, when the SBA was normalized by total particle volume (mm3/gm tissue) or by component wear volume rate (mm3/year), functional biological activity of the HXLPE wear debris was significantly decreased compared to the CPE cohort. Indications for this study are that the osteolytic potential of wear debris generated by HXLPE liners in vivo is significantly reduced by improvements in polyethylene wear resistance. (c) 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 101B: 467475, 2013.
引用
收藏
页码:467 / 475
页数:9
相关论文
共 50 条
  • [1] In vivo wear of large femoral heads on highly cross-linked polyethylene.
    Aspey, B
    Beaulé, PE
    Martell, J
    Ebramzadeh, E
    Amstutz, HC
    JOURNAL OF INVESTIGATIVE MEDICINE, 2006, 54 (01) : S114 - S114
  • [2] Wear in conventional and highly cross-linked polyethylene cups
    Olyslaegers, Christophe
    Defoort, Koen
    Simon, Jean-Pierre
    Vandenberghe, Luc
    JOURNAL OF ARTHROPLASTY, 2008, 23 (04): : 489 - 494
  • [3] In vivo wear and migration of highly cross-linked polyethylene cups -: A radiostereometry analysis study
    Röhrl, S
    Nivbrant, B
    Mingguo, L
    Hewitt, B
    JOURNAL OF ARTHROPLASTY, 2005, 20 (04): : 409 - 413
  • [4] Short-term in vivo wear of cross-linked polyethylene
    Heisel, C
    Silva, M
    dela Rosa, MA
    Schmalzried, TP
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (04): : 748 - 751
  • [5] Wear of highly cross-linked polyethylene acetabular cup in Japan
    Oonishi, Hironobu
    Kim, Sok Chol
    Takao, Yasuhiro
    Kyomoto, Masayuki
    Iwamoto, Mikio
    Ueno, Masaru
    JOURNAL OF ARTHROPLASTY, 2006, 21 (07): : 944 - 949
  • [6] Wear is Reduced in THA Performed with Highly Cross-linked Polyethylene
    Beksac, Burak
    Salas, Antonio
    Gonzalez Della Valle, Alejandro
    Salvati, Eduardo A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (07) : 1765 - 1772
  • [7] Continued Improved Wear with an Annealed Highly Cross-linked Polyethylene
    Capello, William N.
    D'Antonio, James A.
    Ramakrishnan, Rama
    Naughton, Marybeth
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (03) : 825 - 830
  • [8] In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty
    Manning, DW
    Chiang, PP
    Martell, JM
    Galante, JO
    Harris, WH
    JOURNAL OF ARTHROPLASTY, 2005, 20 (07): : 880 - 886
  • [9] In vivo and in vitro surface changes in a highly cross-linked polyethylene
    Rieker, CB
    Konrad, R
    Schön, R
    Schneider, W
    Abt, NA
    JOURNAL OF ARTHROPLASTY, 2003, 18 (07): : 48 - 54
  • [10] Ex vivo wear of conventional and cross-linked polyethylene acetabular liners
    Muratoglu, OK
    Wannomae, K
    Christensen, S
    Rubash, HE
    Harris, WH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (438) : 158 - 164