Short-term in vivo wear of cross-linked polyethylene

被引:121
|
作者
Heisel, C [1 ]
Silva, M [1 ]
dela Rosa, MA [1 ]
Schmalzried, TP [1 ]
机构
[1] Orthoped Hosp, Joint Replacement Inst, Los Angeles, CA 90007 USA
来源
关键词
D O I
10.2106/00004623-200404000-00012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Cross-linked polyethylene was developed to reduce volumetric wear in prosthetic joints. Hip simulator studies have shown promising results with regard to wear reduction. This study evaluated the short-term in vivo wear of a moderately cross-linked polyethylene. Methods: Linear head penetration, as an assessment of in vivo polyethylene wear, was measured in two groups of patients after total hip replacement. Twenty-four hips received a conventional polyethylene insert and thirty-four, a crosslinked polyethylene liner; both inserts were manufactured by the same company. Linear and volumetric wear rates were measured on radiographs with use of a validated computer-assisted technique and were adjusted for patient-related factors. Patient activity was assessed by a computerized two-dimensional accelerometer worn on the ankle. Results: Patients with a conventional polyethylene insert showed a mean linear wear rate of 0.13 mm per year and a mean volumetric wear rate of 87.6 mm(3) per year. The group with a cross-linked polyethylene liner showed a mean linear wear rate of 0.02 mm per year and a mean volumetric wear rate of 17.0 mm(3) per year. Wear in the group with cross-linked polyethylene was 81% lower than that in the group with conventional polyethylene (p < 0.00001). Accounting for differences in patient activity, the adjusted wear rates per million cycles for a patient weight of 70 kg were 53 mm(3) per million cycles for conventional polyethylene and 15 mm(3) per million cycles for cross-linked polyethylene, a 72% reduction (p = 0.0002). No factor, other than the type of polyethylene, was found to influence the difference in wear rates between the two groups. Conclusions: The results of this study are promising. The in vivo wear reduction with this cross-linked polyethylene is consistent with the predictions of hip simulator studies. Level of Evidence: Therapeutic study, Level II-1 (prospective cohort study). See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:748 / 751
页数:4
相关论文
共 50 条
  • [1] Short-term wear of Japanese highly cross-linked polyethylene in cementless THA
    Miyanishi, Keita
    Hara, Toshihiko
    Kaminomachi, Shigekazu
    Maekawa, Masayuki
    Iwamoto, Mikio
    Torisu, Takehiko
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (09) : 995 - 1000
  • [2] Short-term wear of Japanese highly cross-linked polyethylene in cementless THA
    Keita Miyanishi
    Toshihiko Hara
    Shigekazu Kaminomachi
    Masayuki Maekawa
    Mikio Iwamoto
    Takehiko Torisu
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 995 - 1000
  • [3] Characteristics of highly cross-linked polyethylene wear debris in vivo
    Baxter, Ryan M.
    MacDonald, Daniel W.
    Kurtz, Steven M.
    Steinbeck, Marla J.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2013, 101B (03) : 467 - 475
  • [4] Comparison of cross-linked polyethylene compounds by short-term electrical and thermal tests
    Montanari, GC
    Mazzanti, G
    Motori, A
    Campus, A
    Nilsson, UH
    IEEE 1997 ANNUAL REPORT - CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, VOLS I AND II, 1997, : 287 - 291
  • [5] Ex vivo wear of conventional and cross-linked polyethylene acetabular liners
    Muratoglu, OK
    Wannomae, K
    Christensen, S
    Rubash, HE
    Harris, WH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (438) : 158 - 164
  • [6] Short-Term Surface Damage Mechanisms of Retrieved Highly Cross-Linked Polyethylene Patellar Components
    Derr, Tabitha
    MacDonald, Daniel W.
    Klein, Gregg R.
    Mont, Michael A.
    Piuzzi, Nicolas S.
    Kurtz, Steven M.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (05): : 939 - +
  • [7] In vivo wear of large femoral heads on highly cross-linked polyethylene.
    Aspey, B
    Beaulé, PE
    Martell, J
    Ebramzadeh, E
    Amstutz, HC
    JOURNAL OF INVESTIGATIVE MEDICINE, 2006, 54 (01) : S114 - S114
  • [8] Short-term outcomes of thin highly cross-linked polyethylene liners in primary total hip arthroplasty
    Bieganowski, Thomas
    Singh, Vivek
    Muthusamy, Nishanth
    Kugelman, David N.
    Davidovitch, Roy, I
    Schwarzkopf, Ran
    HIP INTERNATIONAL, 2023, 33 (05) : 839 - 844
  • [9] In vivo wear and migration of highly cross-linked polyethylene cups -: A radiostereometry analysis study
    Röhrl, S
    Nivbrant, B
    Mingguo, L
    Hewitt, B
    JOURNAL OF ARTHROPLASTY, 2005, 20 (04): : 409 - 413
  • [10] The influence of contact stress on the wear of cross-linked polyethylene
    Kandemir, Goeksu
    Smith, Simon
    Joyce, Thomas J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (10) : 1008 - 1016