In vivo wear and migration of highly cross-linked polyethylene cups -: A radiostereometry analysis study

被引:59
|
作者
Röhrl, S
Nivbrant, B
Mingguo, L
Hewitt, B
机构
[1] Umea Univ, Dept Surg & Perioperat Sci, Umea, Sweden
[2] Univ Western Australia, Dept Orthopaed Surg, Nedlands, WA 6009, Australia
来源
JOURNAL OF ARTHROPLASTY | 2005年 / 20卷 / 04期
关键词
wear; migration; cross-linked; polyethylene; THA;
D O I
10.1016/j.arth.2004.09.040
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In 50 cemented hip arthroplasties, wear and migration of the polyethylene (PE) cups were measured with radiostereometric analysis for a period of 2 years. Twenty had a normal gamma-in-air-sterilized PE, another 20 had a PE sterilized with 30000 Gy followed by heat stabilization (Duration; Stryker Orthopaedics, Mahwah, NJ), and 10 had highly cross-linked PE cups irradiated with 100000 Gy (Crossfire; Stryker Orthopaedics). In the initial 2 months, head penetration (creep) was 63 mu m on average for the 3 groups. From 2 to 24 months, the mean proximal head penetration (wear) was 156 mu m for standard PE, 138 mu m for stabilized PE (P = .45), and 23 mu m for highly cross-linked PE (P < .001; analysis of variance). The low in vivo wear rate for highly cross-linked cups was not at the expense of higher migration or less favorable clinical outcome and looks promising. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:409 / 413
页数:5
相关论文
共 50 条
  • [1] Wear in conventional and highly cross-linked polyethylene cups
    Olyslaegers, Christophe
    Defoort, Koen
    Simon, Jean-Pierre
    Vandenberghe, Luc
    JOURNAL OF ARTHROPLASTY, 2008, 23 (04): : 489 - 494
  • [2] Characteristics of highly cross-linked polyethylene wear debris in vivo
    Baxter, Ryan M.
    MacDonald, Daniel W.
    Kurtz, Steven M.
    Steinbeck, Marla J.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2013, 101B (03) : 467 - 475
  • [3] In vivo wear of large femoral heads on highly cross-linked polyethylene.
    Aspey, B
    Beaulé, PE
    Martell, J
    Ebramzadeh, E
    Amstutz, HC
    JOURNAL OF INVESTIGATIVE MEDICINE, 2006, 54 (01) : S114 - S114
  • [4] In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty
    Manning, DW
    Chiang, PP
    Martell, JM
    Galante, JO
    Harris, WH
    JOURNAL OF ARTHROPLASTY, 2005, 20 (07): : 880 - 886
  • [5] Wear of a highly cross-linked polyethylene liner: a preliminary RSA study
    Campbell, David
    Mercer, Graham
    Nilsson, Kjell-Gunnar
    Wells, Vanessa
    Field, John R.
    Callary, Stuart A.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2010, 20 (01): : 23 - 27
  • [6] Wear of a highly cross-linked polyethylene liner: a preliminary RSA study
    David Campbell
    Graham Mercer
    Kjell-Gunnar Nilsson
    Vanessa Wells
    John R. Field
    Stuart A. Callary
    European Journal of Orthopaedic Surgery & Traumatology, 2010, 20 : 23 - 27
  • [7] Wear and Migration of Highly Cross-Linked and Conventional Cemented Polyethylene Cups with Cobalt Chrome or Oxinium Femoral Heads: A Randomized Radiostereometric Study of 150 Patients
    Kadar, Thomas
    Hallan, Geir
    Aamodt, Arild
    Indrekvam, Kari
    Badawy, Mona
    Skredderstuen, Arne
    Havelin, Leif Ivar
    Stokke, Terje
    Haugan, Kristin
    Espehaug, Birgitte
    Furnes, Ove
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (08) : 1222 - 1229
  • [8] In-vivo degradation of middle-term highly cross-linked and remelted polyethylene cups: Modification induced by creep, wear and oxidation
    Miura, Yoshihiro
    Hasegawa, Masahiro
    Sudo, Akihiro
    Pezzotti, Giuseppe
    Puppulin, Leonardo
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2015, 51 : 13 - 24
  • [9] Short-term in vivo wear of cross-linked polyethylene
    Heisel, C
    Silva, M
    dela Rosa, MA
    Schmalzried, TP
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (04): : 748 - 751
  • [10] Wear of highly cross-linked polyethylene acetabular cup in Japan
    Oonishi, Hironobu
    Kim, Sok Chol
    Takao, Yasuhiro
    Kyomoto, Masayuki
    Iwamoto, Mikio
    Ueno, Masaru
    JOURNAL OF ARTHROPLASTY, 2006, 21 (07): : 944 - 949