Short-term in vivo wear of cross-linked polyethylene

被引:121
|
作者
Heisel, C [1 ]
Silva, M [1 ]
dela Rosa, MA [1 ]
Schmalzried, TP [1 ]
机构
[1] Orthoped Hosp, Joint Replacement Inst, Los Angeles, CA 90007 USA
来源
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME | 2004年 / 86A卷 / 04期
关键词
D O I
10.2106/00004623-200404000-00012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Cross-linked polyethylene was developed to reduce volumetric wear in prosthetic joints. Hip simulator studies have shown promising results with regard to wear reduction. This study evaluated the short-term in vivo wear of a moderately cross-linked polyethylene. Methods: Linear head penetration, as an assessment of in vivo polyethylene wear, was measured in two groups of patients after total hip replacement. Twenty-four hips received a conventional polyethylene insert and thirty-four, a crosslinked polyethylene liner; both inserts were manufactured by the same company. Linear and volumetric wear rates were measured on radiographs with use of a validated computer-assisted technique and were adjusted for patient-related factors. Patient activity was assessed by a computerized two-dimensional accelerometer worn on the ankle. Results: Patients with a conventional polyethylene insert showed a mean linear wear rate of 0.13 mm per year and a mean volumetric wear rate of 87.6 mm(3) per year. The group with a cross-linked polyethylene liner showed a mean linear wear rate of 0.02 mm per year and a mean volumetric wear rate of 17.0 mm(3) per year. Wear in the group with cross-linked polyethylene was 81% lower than that in the group with conventional polyethylene (p < 0.00001). Accounting for differences in patient activity, the adjusted wear rates per million cycles for a patient weight of 70 kg were 53 mm(3) per million cycles for conventional polyethylene and 15 mm(3) per million cycles for cross-linked polyethylene, a 72% reduction (p = 0.0002). No factor, other than the type of polyethylene, was found to influence the difference in wear rates between the two groups. Conclusions: The results of this study are promising. The in vivo wear reduction with this cross-linked polyethylene is consistent with the predictions of hip simulator studies. Level of Evidence: Therapeutic study, Level II-1 (prospective cohort study). See Instructions to Authors for a complete description of levels of evidence.
引用
收藏
页码:748 / 751
页数:4
相关论文
共 50 条
  • [21] Aggressive wear testing of a cross-linked polyethylene in total knee arthroplasty
    Muratoglu, OK
    Bragdon, CR
    O'Connor, DO
    Perinchief, RS
    Jasty, M
    Harris, WH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) : 89 - 95
  • [22] Wear rate and medium-term survival of a cemented, moderately cross-linked polyethylene acetabular prosthesis
    Barkatali, Bilal M.
    Alexander, Dinesh P.
    Gambhir, Anil K.
    Jones, Henry Wynn
    Board, Tim N.
    HIP INTERNATIONAL, 2018, 28 (01) : 53 - 58
  • [23] MORPHOLOGY OF CROSS-LINKED POLYETHYLENE
    不详
    EPRI JOURNAL, 1983, 8 (08): : 47 - 47
  • [24] PHOTODEGRADATION OF CROSS-LINKED POLYETHYLENE
    TORIKAI, A
    ASADA, S
    FUEKI, K
    POLYMER PHOTOCHEMISTRY, 1986, 7 (01): : 1 - 11
  • [25] ON THE CRYSTALLIZATION OF CROSS-LINKED POLYETHYLENE
    BONGARDT, J
    MAY, M
    PLASTE UND KAUTSCHUK, 1986, 33 (05): : 172 - 175
  • [26] STABILIZATION OF CROSS-LINKED POLYETHYLENE
    STENGREVICS, E
    KING, RE
    HOFMANN, P
    POLYOLEFINS VI: SIXTH INTERNATIONAL CONFERENCE ON POLYOLEFINS, 1989, : 331 - 346
  • [27] The electrical long-term performance of cross-linked polyethylene
    Olshausen, R.V.
    Weißenberg, W.
    2001, Meisenbach GmbH (50):
  • [28] LACK OF GENOTOXICITY OF CROSS-LINKED ACRYLATE POLYMERS IN 4 SHORT-TERM GENOTOXICITY ASSAYS
    THOMPSON, ED
    SEYMOUR, JL
    AARDEMA, MJ
    LEBOEUF, RA
    EVANS, BLB
    CODY, DB
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 1991, 18 (03) : 184 - 199
  • [29] Sequentially annealed highly cross-linked polyethylene reduced in vivo wear particle generation in total knee arthroplasty
    Minoda, Yukihide
    Hata, Kanako
    Goto, Katsuko
    Itohara, Tomonobu
    Nakamura, Hiroaki
    JOURNAL OF ORTHOPAEDIC SURGERY, 2017, 25 (02):
  • [30] Different wear in two highly cross-linked polyethylene liners in THA: wear analysis with EBRA
    D. Dammerer
    A. Keiler
    D. Putzer
    F. Lenze
    M. Liebensteiner
    M. Thaler
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1591 - 1599