Characteristics of highly cross-linked polyethylene wear debris in vivo

被引:29
|
作者
Baxter, Ryan M. [1 ]
MacDonald, Daniel W. [1 ]
Kurtz, Steven M. [1 ,3 ]
Steinbeck, Marla J. [1 ,2 ]
机构
[1] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, Philadelphia, PA 19104 USA
[2] Drexel Univ, Coll Drexel Med, Philadelphia, PA 19104 USA
[3] Exponent Inc, Philadelphia, PA USA
关键词
total hip replacementhighly cross-linked polyethyleneosteolysiswear debrisbiological activity; MOLECULAR-WEIGHT POLYETHYLENE; TOTAL HIP-ARTHROPLASTY; FUNCTIONAL BIOLOGICAL-ACTIVITY; CONVENTIONAL POLYETHYLENE; UHMWPE PARTICLES; PERIPROSTHETIC TISSUE; MECHANICAL-PROPERTIES; 5-YEAR EXPERIENCE; GAMMA-RADIATION; EARLY FAILURE;
D O I
10.1002/jbm.b.32902
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Despite the widespread implementation of highly cross-linked polyethylene (HXLPE) liners to reduce the clinical incidence of osteolysis, it is not known if the improved wear resistance will outweigh the inflammatory potential of HXLPE wear debris generated in vivo. Thus, we asked: What are the differences in size, shape, number, and biological activity of polyethylene wear particles obtained from primary total hip arthroplasty revision surgery of conventional polyethylene (CPE) versus remelted or annealed HXLPE liners? Pseudocapsular tissue samples were collected from revision surgery of CPE and HXLPE (annealed and remelted) liners, and digested using nitric acid. The isolated polyethylene wear particles were evaluated using scanning electron microscopy. Tissues from both HXLPE cohorts contained an increased percentage of submicron particles compared to the CPE cohort. However, the total number of particles was lower for both HXLPE cohorts, as a result there was no significant difference in the volume fraction distribution and specific biological activity (SBA; the relative biological activity per unit volume) between cohorts. In contrast, based on the decreased size and number of HXLPE wear debris there was a significant decrease in total particle volume (mm3/g of tissue). Accordingly, when the SBA was normalized by total particle volume (mm3/gm tissue) or by component wear volume rate (mm3/year), functional biological activity of the HXLPE wear debris was significantly decreased compared to the CPE cohort. Indications for this study are that the osteolytic potential of wear debris generated by HXLPE liners in vivo is significantly reduced by improvements in polyethylene wear resistance. (c) 2013 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 101B: 467475, 2013.
引用
收藏
页码:467 / 475
页数:9
相关论文
共 50 条
  • [21] Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners
    Bradford, L
    Baker, DA
    Graham, J
    Chawan, A
    Ries, MD
    Pruitt, LA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (06): : 1271 - 1282
  • [22] Short-term wear of Japanese highly cross-linked polyethylene in cementless THA
    Miyanishi, Keita
    Hara, Toshihiko
    Kaminomachi, Shigekazu
    Maekawa, Masayuki
    Iwamoto, Mikio
    Torisu, Takehiko
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (09) : 995 - 1000
  • [23] Short-term wear of Japanese highly cross-linked polyethylene in cementless THA
    Keita Miyanishi
    Toshihiko Hara
    Shigekazu Kaminomachi
    Masayuki Maekawa
    Mikio Iwamoto
    Takehiko Torisu
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 995 - 1000
  • [24] The influence of contact stress on the wear of cross-linked polyethylene
    Kandemir, Goeksu
    Smith, Simon
    Joyce, Thomas J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (10) : 1008 - 1016
  • [25] Wear testing of a canine hip resurfacing implant that uses highly cross-linked polyethylene
    Warburton, Kevin J.
    Everingham, John B.
    Helms, Jillian L.
    Kazanovicz, Andrew J.
    Hollar, Katherine A.
    Brourman, Jeff D.
    Fox, Steven M.
    Lujan, Trevor J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2018, 36 (04) : 1196 - 1205
  • [26] Simulated normal gait wear testing of a highly cross-linked polyethylene tibial insert
    Muratoglu, Orhun K.
    Rubash, Harry E.
    Bragdon, Charles R.
    Burroughs, Brian R.
    Huang, Anna
    Harris, William H.
    JOURNAL OF ARTHROPLASTY, 2007, 22 (03): : 435 - 444
  • [27] Wear of Vitamin E-Infused Highly Cross-Linked Polyethylene at Five Years
    Shareghi, Bita
    Johanson, Per-Erik
    Karrholm, Johan
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (17): : 1447 - 1452
  • [28] Second-generation Annealed Highly Cross-linked Polyethylene Exhibits Low Wear
    D'Antonio, James A.
    Capello, William N.
    Ramakrishnan, Rama
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2012, 470 (06) : 1696 - 1704
  • [29] Femoral Head Size and Wear of Highly Cross-linked Polyethylene at 5 to 8 Years
    Lachiewicz, Paul F.
    Heckman, Daniel S.
    Soileau, Elizabeth S.
    Mangla, Jimmi
    Martell, John M.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (12) : 3290 - 3296
  • [30] In Vivo Oxidative Stability Changes of Highly Cross-Linked Polyethylene Bearings: An Ex Vivo Investigation
    Rowell, Shannon L.
    Reyes, Christopher R.
    Malchau, Henrik
    Muratoglu, Orhun K.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (10): : 1828 - 1834