Assessing the Performance of Handheld Glucose Testing for Critical Care

被引:15
|
作者
Kost, Gerald J. [1 ,2 ]
Tran, Nam K. [1 ,2 ]
Louie, Richard F. [1 ,2 ]
Gentile, Nicole L. [1 ,2 ]
Abad, Victor J. [3 ]
机构
[1] Univ Calif Davis, Point Care Testing Ctr Teaching & Res, Sch Med, Davis, CA 95616 USA
[2] Univ Calif Davis, Univ Calif Lawrence Livermore Natl Lab, Ctr Point Care Technol, Davis, CA 95616 USA
[3] Epsilon Grp LLC, Charlottesville, VA USA
关键词
D O I
10.1089/dia.2008.0049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We assessed the performance of a point-of-care (POC) glucose meter system (GMS) with multitasking test strip by using the locally-smoothed (LS) median absolute difference (MAD) curve method in conjunction with a modified Bland-Altman difference plot and superimposed International Organization for Standardization (ISO) 15197 tolerance bands. We analyzed performance for tight glycemic control (TGC). Methods: A modified glucose oxidase enzyme with a multilayer-gold, multielectrode, four-well test strip (StatStrip (TM), NOVA Biomedical, Waltham, MA) was used. There was no test strip calibration code. Pragmatic comparison was done of GMS results versus paired plasma glucose measurements from chemistry analyzers in clinical laboratories. Venous samples (n = 1,703) were analyzed at 35 hospitals that used 20 types of chemistry analyzers. Erroneous results were identified using the Bland-Altman plot and ISO 15197 criteria. Discrepant values were analyzed for the TGC interval of 80-110 mg/dL. Results: The GMS met ISO 15197 guidelines; 98.6% (410 of 416) of observations were within tolerance for glucose <75 mg/dL, and for >= 75 mg/dL, 100% were within tolerance. Paired differences (handheld. minus reference) averaged -2.2 (SD 9.8) mg/dL; the median was -1 (range, -96 to 45) mg/dL. LS MAD curve analysis revealed satisfactory performance below 186 mg/dL; above 186 mg/dL, the recommended error tolerance limit (5 mg/dL) was not met. No discrepant values appeared. All points fell in Clarke Error Grid zone A. Linear regression showed y = 1.018x - 0.716 mg/dL, and r(2) = 0.995. Conclusions: LS MAD curves draw on human ability to discriminate performance visually. LS MAD curve and ISO 15197 performance were acceptable for TGC. POC and reference glucose calibration should be harmonized and standardized.
引用
收藏
页码:445 / 451
页数:7
相关论文
共 50 条
  • [31] 'Condition critical (?)′:: assessing the condition of US critical care
    Kuczkowski, KM
    Eisenmann, UB
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2005, 49 (06) : 883 - 883
  • [32] A cost-effective, high-performance approach to critical care testing
    Weilert, W
    Workman, RD
    Danaye-Elmi, M
    Darmanian, C
    LABORATORY MEDICINE, 1999, 30 (09) : 601 - 604
  • [33] Critical evaluation of connectivity-based point of care testing systems of glucose in a hospital environment
    Flore, Katelijne M. J.
    Fiers, Tom
    Delanghe, Joris R.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2008, 46 (12) : 1763 - 1768
  • [34] GLUCOSE CONTROL IN CRITICAL CARE ONCOLOGY
    Cooksley, Timothy
    McAvoy, Thomas
    Haji-Michael, Philip
    CRITICAL CARE MEDICINE, 2010, 38 (12) : U254 - U254
  • [35] Blood Glucose Concentration and Critical Care
    Hartl, W. H.
    Jauch, K. -W.
    AKTUELLE ERNAHRUNGSMEDIZIN, 2006, 31 : S81 - S88
  • [36] Assessing the Technical and Analytical Performance of Point of Care Testing Devices for Blood Lipids Measurements
    Dahya, K.
    Pokuah, F.
    Earl, K. R.
    Cohen, D. B.
    Danilenko, U.
    Vesper, H. W.
    CLINICAL CHEMISTRY, 2024, 70 : I128 - I128
  • [37] Laboratory investigation for the assessment of haematocrit interference on handheld blood glucose meters for patients' self blood glucose testing
    Forst, T.
    Musholt, P. B.
    Schneider, M.
    Dannappel, M.
    Pfuetzner, A.
    DIABETOLOGIA, 2009, 52 : S368 - S368
  • [38] Performance of point-of-care glucose testing for the diagnosis of gestational diabetes in South Africa
    Khambule, L.
    Chikomba, C.
    Adam, Y.
    Khan, L.
    Haldane, C.
    Vetter, B.
    George, J.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2025, 168 (02) : 812 - 821
  • [39] LCD display screen performance testing for handheld thermal imaging cameras
    Dinaburg, Joshua B.
    Amon, Francine
    Hamins, Anthony
    Boynton, Paul
    INFRARED IMAGING SYSTEMS: DESIGN, ANALYSIS, MODELING, AND TESTING XVII, 2006, 6207
  • [40] Routine HIV testing in critical care
    Umaipalan, A.
    Dakshina, S.
    Khan, P.
    Bunker, N.
    Orkin, C.
    HIV MEDICINE, 2016, 17 : 56 - 56