LCD display screen performance testing for handheld thermal imaging cameras

被引:0
|
作者
Dinaburg, Joshua B. [1 ]
Amon, Francine [1 ]
Hamins, Anthony [1 ]
Boynton, Paul [1 ]
机构
[1] Natl Inst Stand & Technol, 100 Bur Dr, Gaithersburg, MD 20899 USA
关键词
characterization; thermal imager; display performance; performance metrics; non-destructive testing; infrared camera; TIC;
D O I
10.1117/12.666280
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
Handheld thermal imaging cameras are an important tool for the first responder community. As their use becomes more prevalent, it will become important for a set of standard test metrics to be available to characterize the performance of these cameras. A major factor in the performance of the imagers is the quality of the image on a display screen. An imager may employ any type of display screen, but the results of this paper will focus on those using liquid crystal displays. First responders, especially firefighters, in the field rely on the performance of this screen to relay vital information during critical situations. Current research on thermal imaging camera performance metrics for first responder applications uses trained observer tests or camera composite output signal measurements. Trained observer tests are subjective and composite output tests do not evaluate the performance of the complete imaging system. It is the goal of this work to develop a nondestructive, objective method that tests the performance of the entire thermal imaging camera system, from the infrared sensor to the display screen. Application of existing display screen performance metrics to thermal imaging cameras requires additional consideration. Most display screen test metrics require a well defined electronic input, with either full black or white pixel input, often encompassing detailed spatial patterns and resolution. Well characterized thermal inputs must be used to obtain accurate, repeatable, and non-destructive display screen measurements for infrared cameras. For this work, a thermal target is used to correlate the measured camera output with the actual display luminance. A test method was developed to determine display screen luminance. A well characterized CCD camera and digital recording device were used to determine an electro-optical transfer function for thermal imaging cameras. This value directly relates the composite output signal to the luminance of the display screen, providing a realistic characterization of system performance.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] First responder thermal imaging cameras: establishment of representative performance testing conditions
    Amon, Francine
    Hamins, Anthony
    Rowe, Justin
    THERMOSENSE XXVIII, 2006, 6205
  • [2] Design of LCD Display System for Handheld Devices Based on Linux
    Li Minglei
    Chen Guiying
    Shang Xiaodong
    Mao Huabin
    2011 INTERNATIONAL CONFERENCE ON ELECTRONICS, COMMUNICATIONS AND CONTROL (ICECC), 2011, : 822 - 825
  • [3] Effects of Display Screen Type on Perception and Visual Performance Does AMOLED screen perform better than LCD screen?
    Qiu, Jingjing
    Jin, Chun
    Lin, Yandan
    Gao, Yanpin
    Tsou, Chungche
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON LOGISTICS, ENGINEERING, MANAGEMENT AND COMPUTER SCIENCE, 2014, 101 : 1087 - 1090
  • [4] Small-sized CRT display for television and thermal imaging cameras
    Sosnovik, MI
    Vasilyev, IS
    Markizov, AS
    Petrov, IN
    Fedotenkov, UF
    18th International Conference on Photoelectronics and Night Vision Devices, 2005, 5834 : 143 - 146
  • [5] Improved thermal imaging cameras boost weapons testing capability
    Caffee, L
    Keller, P
    PHOTONICS SPECTRA, 1996, 30 (08) : 102 - 103
  • [6] Applications for high-performance thermal imaging cameras
    Richards, AA
    THERMOSENSE XXIV, 2002, 4710 : 464 - 467
  • [7] Image Frequency Analysis for Testing of Fire Service Thermal Imaging Cameras
    Amon, Francine
    Ducharme, Alfred
    FIRE TECHNOLOGY, 2009, 45 (03) : 313 - 322
  • [8] Image Frequency Analysis for Testing of Fire Service Thermal Imaging Cameras
    Francine Amon
    Alfred Ducharme
    Fire Technology, 2009, 45 : 313 - 322
  • [9] Feasibility and clinical utility of handheld fundus cameras for retinal imaging
    Susmit Das
    Helen J. Kuht
    Ian De Silva
    Sundeep S. Deol
    Lina Osman
    Joyce Burns
    Nagini Sarvananthan
    Usman Sarodia
    Bharat Kapoor
    Tahir Islam
    Raghavan Sampath
    Alicia Poyser
    Vasileios Konidaris
    Rossella Anzidei
    Frank A. Proudlock
    Mervyn G. Thomas
    Eye, 2023, 37 : 274 - 279
  • [10] Feasibility and clinical utility of handheld fundus cameras for retinal imaging
    Das, Susmit
    Kuht, Helen J.
    de Silva, Ian
    Deol, Sundeep S.
    Osman, Lina
    Burns, Joyce
    Sarvananthan, Nagini
    Sarodia, Usman
    Kapoor, Bharat
    Islam, Tahir
    Sampath, Raghavan
    Poyser, Alicia
    Konidaris, Vasileios
    Anzidei, Rossella
    Proudlock, Frank A.
    Thomas, Mervyn G.
    EYE, 2023, 37 (02) : 274 - 279