Assessing the Performance of Handheld Glucose Testing for Critical Care

被引:15
|
作者
Kost, Gerald J. [1 ,2 ]
Tran, Nam K. [1 ,2 ]
Louie, Richard F. [1 ,2 ]
Gentile, Nicole L. [1 ,2 ]
Abad, Victor J. [3 ]
机构
[1] Univ Calif Davis, Point Care Testing Ctr Teaching & Res, Sch Med, Davis, CA 95616 USA
[2] Univ Calif Davis, Univ Calif Lawrence Livermore Natl Lab, Ctr Point Care Technol, Davis, CA 95616 USA
[3] Epsilon Grp LLC, Charlottesville, VA USA
关键词
D O I
10.1089/dia.2008.0049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We assessed the performance of a point-of-care (POC) glucose meter system (GMS) with multitasking test strip by using the locally-smoothed (LS) median absolute difference (MAD) curve method in conjunction with a modified Bland-Altman difference plot and superimposed International Organization for Standardization (ISO) 15197 tolerance bands. We analyzed performance for tight glycemic control (TGC). Methods: A modified glucose oxidase enzyme with a multilayer-gold, multielectrode, four-well test strip (StatStrip (TM), NOVA Biomedical, Waltham, MA) was used. There was no test strip calibration code. Pragmatic comparison was done of GMS results versus paired plasma glucose measurements from chemistry analyzers in clinical laboratories. Venous samples (n = 1,703) were analyzed at 35 hospitals that used 20 types of chemistry analyzers. Erroneous results were identified using the Bland-Altman plot and ISO 15197 criteria. Discrepant values were analyzed for the TGC interval of 80-110 mg/dL. Results: The GMS met ISO 15197 guidelines; 98.6% (410 of 416) of observations were within tolerance for glucose <75 mg/dL, and for >= 75 mg/dL, 100% were within tolerance. Paired differences (handheld. minus reference) averaged -2.2 (SD 9.8) mg/dL; the median was -1 (range, -96 to 45) mg/dL. LS MAD curve analysis revealed satisfactory performance below 186 mg/dL; above 186 mg/dL, the recommended error tolerance limit (5 mg/dL) was not met. No discrepant values appeared. All points fell in Clarke Error Grid zone A. Linear regression showed y = 1.018x - 0.716 mg/dL, and r(2) = 0.995. Conclusions: LS MAD curves draw on human ability to discriminate performance visually. LS MAD curve and ISO 15197 performance were acceptable for TGC. POC and reference glucose calibration should be harmonized and standardized.
引用
收藏
页码:445 / 451
页数:7
相关论文
共 50 条
  • [21] Assessing outcomes in critical care
    Watson, RS
    Angus, DC
    JOURNAL OF INTENSIVE CARE MEDICINE, 2002, 17 (03) : 103 - 111
  • [22] Assessing the Microcirculation With Handheld Vital Microscopy in Critically Ill Neonates and Children: Evolution of the Technique and Its Potential for Critical Care
    Erdem, Ozge
    Ince, Can
    Tibboel, Dick
    Kuiper, Jan Willem
    FRONTIERS IN PEDIATRICS, 2019, 7
  • [23] Glucose control in critical care
    Clain, Jeremy
    Ramar, Kannan
    Surani, Salim R.
    WORLD JOURNAL OF DIABETES, 2015, 6 (09): : 1082 - 1091
  • [24] Update on glucose in critical care
    Lheureux, Olivier
    Prevedello, Danielle
    Preiser, Jean-Charles
    NUTRITION, 2019, 59 : 14 - 20
  • [25] Handheld testing
    Cleaveland, Peter
    CONTROL ENGINEERING, 2008, 55 (04) : 58 - +
  • [26] Assessing critical care unit performance: A global measure using graphical analysis
    Leary, T
    Ridley, S
    Burchett, K
    Kong, A
    Chrispin, P
    Wright, M
    ANAESTHESIA, 2002, 57 (08) : 751 - 755
  • [27] POTENTIAL ROLE OF NURSES IN ASSESSING HOUSE OFFICER PERFORMANCE IN THE CRITICAL CARE ENVIRONMENT
    SHATNEY, CH
    FRIEND, BE
    CRITICAL CARE MEDICINE, 1984, 12 (02) : 117 - 120
  • [28] Proficiency Testing Performance for Point of Care Glucose Users in a Tertiary Hospital in Kenya
    Mukunya, F. M.
    Amayo, A. A.
    Ongeso, A.
    Gitau, A.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2021, 156 : S32 - S33
  • [29] Point-of-Care Testing of Blood Glucose: Clinical Performance and Laboratory Efficiency
    Shih, Wei-Shang
    Yang, Pei-Fang
    Chi, Tzu-Fei
    Huang, Liang Li
    Chen, Chang-I
    Wang, Mei-Xuan
    Ho, Yi-Ting
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (09) : BC10 - BC13
  • [30] URINE GLUCOSE TESTING BY GLUCOSE OXIDASE METHODS - A CRITICAL EVALUATION
    JABLOKOW, V
    HUTCHINS, M
    KNIGHTS, EM
    DIABETES, 1957, 6 (05) : 426 - 427