Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between magnetic resonance scanners

被引:59
|
作者
Raman, Fabio S. [1 ]
Kawel-Boehm, Nadine [1 ,2 ]
Gai, Neville [1 ]
Freed, Melanie [3 ]
Han, Jing [4 ]
Liu, Chia-Ying [1 ]
Lima, Joao A. C. [5 ]
Bluemke, David A. [1 ,6 ]
Liu, Songtao [1 ,6 ]
机构
[1] NIH, Ctr Clin, Bethesda, MD 20892 USA
[2] Univ Basel Hosp, Clin Radiol & Nucl Med, CH-4031 Basel, Switzerland
[3] NYU, Sch Med, New York, NY USA
[4] US FDA, Rockville, MD 20857 USA
[5] Johns Hopkins Univ, Sch Med, Div Cardiol, Baltimore, MD USA
[6] Natl Inst Biomed Imaging & Bioengn, Mol Biomed Imaging Lab, Bethesda, MD USA
基金
美国国家卫生研究院;
关键词
T1; mapping; Partition coefficient (lambda); Extracellular volume fraction (ECV); Diffuse myocardial fibrosis; Modified look-locker with inversion recovery (MOLLI); DIFFUSE MYOCARDIAL FIBROSIS; EXTRACELLULAR VOLUME FRACTION; INTRAINDIVIDUAL ASSESSMENT; GD-DTPA; VALIDATION; QUANTIFICATION; ASSOCIATION; RELAXATION; INFARCTION; SHMOLLI;
D O I
10.1186/1532-429X-15-64
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cardiovascular magnetic resonance (CMR) T1 mapping indices, such as T1 time and partition coefficient (lambda), have shown potential to assess diffuse myocardial fibrosis. The purpose of this study was to investigate how scanner and field strength variation affect the accuracy and precision/reproducibility of T1 mapping indices. Methods: CMR studies were performed on two 1.5T and three 3T scanners. Eight phantoms were made to mimic the T1/T2 of pre- and post-contrast myocardium and blood at 1.5T and 3T. T1 mapping using MOLLI was performed with simulated heart rate of 40-100 bpm. Inversion recovery spin echo (IR-SE) was the reference standard for T1 determination. Accuracy was defined as the percent error between MOLLI and IR-SE, and scan/re-scan reproducibility was defined as the relative percent mean difference between repeat MOLLI scans. Partition coefficient was estimated by Delta R1myocardium phantom/Delta R1blood phantom. Generalized linear mixed model was used to compare the accuracy and precision/reproducibility of T1 and lambda across field strength, scanners, and protocols. Results: Field strength significantly affected MOLLI T1 accuracy (6.3% error for 1.5T vs. 10.8% error for 3T, p<0.001) but not lambda accuracy (8.8% error for 1.5T vs. 8.0% error for 3T, p=0.11). Partition coefficients of MOLLI were not different between two 1.5T scanners (47.2% vs. 47.9%, p=0.13), and showed only slight variation across three 3T scanners (49.2% vs. 49.8% vs. 49.9%, p=0.016). Partition coefficient also had significantly lower percent error for precision (better scan/re-scan reproducibility) than measurement of individual T1 values (3.6% for lambda vs. 4.3%-4.8% for T1 values, approximately, for pre/post blood and myocardium values). Conclusion: Based on phantom studies, T1 errors using MOLLI ranged from 6-14% across various MR scanners while errors for partition coefficient were less (6-10%). Compared with absolute T1 times, partition coefficient showed less variability across platforms and field strengths as well as higher precision.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Z-score mapping for standardized analysis and reporting of cardiovascular magnetic resonance modified Look-Locker inversion recovery (MOLLI) T1 data: Normal behavior and validation in patients with amyloidosis
    Riccardo Kranzusch
    Fabian aus dem Siepen
    Stephanie Wiesemann
    Leonora Zange
    Sarah Jeuthe
    Tiago Ferreira da Silva
    Titus Kuehne
    Burkert Pieske
    Christoph Tillmanns
    Matthias G. Friedrich
    Jeanette Schulz-Menger
    Daniel R. Messroghli
    Journal of Cardiovascular Magnetic Resonance, 22
  • [32] Influence of Fat on Liver T1 Measurements Using Modified Look-Locker Inversion Recovery (MOLLI) Methods at 3T
    Mozes, Ferenc E.
    Tunnicliffe, Elizabeth M.
    Pavlides, Michael
    Robson, Matthew D.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (01) : 105 - 111
  • [33] Myocardial T1 Mapping With MRI: Comparison of Look-Locker and MOLLI Sequences
    Nacif, Marcelo Souto
    Turkbey, Evrim B.
    Gai, Neville
    Nazarian, Saman
    van der Geest, Rob J.
    Noureldin, Radwa A.
    Sibley, Christopher T.
    Ugander, Martin
    Liu, Songtao
    Arai, Andrew E.
    Lima, Joao A. C.
    Bluemke, David A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (06) : 1367 - 1373
  • [34] Quantitative assessment of hepatic function: modified look-locker inversion recovery (MOLLI) sequence for T1 mapping on Gd-EOB-DTPA-enhanced liver MR imaging
    Yoon, Jeong Hee
    Lee, Jeong Min
    Paek, Munyoung
    Han, Joon Koo
    Choi, Byung Ihn
    EUROPEAN RADIOLOGY, 2016, 26 (06) : 1775 - 1782
  • [35] Rapid 3D T1 mapping using deep learning-assisted Look-Locker inversion recovery MRI
    Pei, Haoyang
    Xia, Ding
    Xu, Xiang
    Yang, Yang
    Wang, Yao
    Liu, Fang
    Feng, Li
    MAGNETIC RESONANCE IN MEDICINE, 2023, 90 (02) : 569 - 582
  • [36] Quantitative assessment of hepatic function: modified look-locker inversion recovery (MOLLI) sequence for T1 mapping on Gd-EOB-DTPA-enhanced liver MR imaging
    Jeong Hee Yoon
    Jeong Min Lee
    Munyoung Paek
    Joon Koo Han
    Byung Ihn Choi
    European Radiology, 2016, 26 : 1775 - 1782
  • [37] Evaluation of T1 relaxation time in prostate cancer and benign prostate tissue using a Modified Look-Locker inversion recovery sequence
    Baur, Alexander D. J.
    Hansen, Carla M.
    Rogasch, Julian
    Posch, Helena
    Elezkurtaj, Sefer
    Maxeiner, Andreas
    Erb-Eigner, Katharina
    Makowski, Marcus R.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [38] Fast T1 mapping of the brain at high field using Look-Locker and
    Jiang, Ke
    Zhu, Yanjie
    Jia, Sen
    Wu, Yin
    Liu, Xin
    Chung, Yiu-Cho
    MAGNETIC RESONANCE IMAGING, 2017, 36 : 49 - 55
  • [39] Evaluation of T1 relaxation time in prostate cancer and benign prostate tissue using a Modified Look-Locker inversion recovery sequence
    Alexander D. J. Baur
    Carla M. Hansen
    Julian Rogasch
    Helena Posch
    Sefer Elezkurtaj
    Andreas Maxeiner
    Katharina Erb-Eigner
    Marcus R. Makowski
    Scientific Reports, 10
  • [40] Correlation of Pancreatic T1 Values Using Modified Look-Locker Inversion Recovery Sequence (MOLLI) with Pancreatic Exocrine and Endocrine Function
    Ashihara, Norihiro
    Watanabe, Takayuki
    Kako, Satoko
    Kuraishi, Yasuhiro
    Ozawa, Makiko
    Shigefuji, Shohei
    Kanai, Keita
    Usami, Yoko
    Yamada, Akira
    Umemura, Takeji
    Fujinaga, Yasunari
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (06) : 1 - 9