Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between magnetic resonance scanners

被引:59
|
作者
Raman, Fabio S. [1 ]
Kawel-Boehm, Nadine [1 ,2 ]
Gai, Neville [1 ]
Freed, Melanie [3 ]
Han, Jing [4 ]
Liu, Chia-Ying [1 ]
Lima, Joao A. C. [5 ]
Bluemke, David A. [1 ,6 ]
Liu, Songtao [1 ,6 ]
机构
[1] NIH, Ctr Clin, Bethesda, MD 20892 USA
[2] Univ Basel Hosp, Clin Radiol & Nucl Med, CH-4031 Basel, Switzerland
[3] NYU, Sch Med, New York, NY USA
[4] US FDA, Rockville, MD 20857 USA
[5] Johns Hopkins Univ, Sch Med, Div Cardiol, Baltimore, MD USA
[6] Natl Inst Biomed Imaging & Bioengn, Mol Biomed Imaging Lab, Bethesda, MD USA
基金
美国国家卫生研究院;
关键词
T1; mapping; Partition coefficient (lambda); Extracellular volume fraction (ECV); Diffuse myocardial fibrosis; Modified look-locker with inversion recovery (MOLLI); DIFFUSE MYOCARDIAL FIBROSIS; EXTRACELLULAR VOLUME FRACTION; INTRAINDIVIDUAL ASSESSMENT; GD-DTPA; VALIDATION; QUANTIFICATION; ASSOCIATION; RELAXATION; INFARCTION; SHMOLLI;
D O I
10.1186/1532-429X-15-64
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cardiovascular magnetic resonance (CMR) T1 mapping indices, such as T1 time and partition coefficient (lambda), have shown potential to assess diffuse myocardial fibrosis. The purpose of this study was to investigate how scanner and field strength variation affect the accuracy and precision/reproducibility of T1 mapping indices. Methods: CMR studies were performed on two 1.5T and three 3T scanners. Eight phantoms were made to mimic the T1/T2 of pre- and post-contrast myocardium and blood at 1.5T and 3T. T1 mapping using MOLLI was performed with simulated heart rate of 40-100 bpm. Inversion recovery spin echo (IR-SE) was the reference standard for T1 determination. Accuracy was defined as the percent error between MOLLI and IR-SE, and scan/re-scan reproducibility was defined as the relative percent mean difference between repeat MOLLI scans. Partition coefficient was estimated by Delta R1myocardium phantom/Delta R1blood phantom. Generalized linear mixed model was used to compare the accuracy and precision/reproducibility of T1 and lambda across field strength, scanners, and protocols. Results: Field strength significantly affected MOLLI T1 accuracy (6.3% error for 1.5T vs. 10.8% error for 3T, p<0.001) but not lambda accuracy (8.8% error for 1.5T vs. 8.0% error for 3T, p=0.11). Partition coefficients of MOLLI were not different between two 1.5T scanners (47.2% vs. 47.9%, p=0.13), and showed only slight variation across three 3T scanners (49.2% vs. 49.8% vs. 49.9%, p=0.016). Partition coefficient also had significantly lower percent error for precision (better scan/re-scan reproducibility) than measurement of individual T1 values (3.6% for lambda vs. 4.3%-4.8% for T1 values, approximately, for pre/post blood and myocardium values). Conclusion: Based on phantom studies, T1 errors using MOLLI ranged from 6-14% across various MR scanners while errors for partition coefficient were less (6-10%). Compared with absolute T1 times, partition coefficient showed less variability across platforms and field strengths as well as higher precision.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Arrhythmia insensitive rapid cardiac T1 mapping: comparison to modified look locker inversion recovery T1 mapping in mitral valve prolapse patients
    Ernest Cheung
    Hui-Chen Han
    Emma Hornsey
    Leonid Churilov
    Kyung Pyo Hong
    Julie Smith
    Daniel Kim
    Omar Farouque
    Andrew Teh
    Han Lim
    Ruth P. Lim
    The International Journal of Cardiovascular Imaging, 2020, 36 : 2017 - 2025
  • [42] Arrhythmia insensitive rapid cardiac T1 mapping: comparison to modified look locker inversion recovery T1 mapping in mitral valve prolapse patients
    Cheung, Ernest
    Han, Hui-Chen
    Hornsey, Emma
    Churilov, Leonid
    Hong, Kyung Pyo
    Smith, Julie
    Kim, Daniel
    Farouque, Omar
    Teh, Andrew
    Lim, Han
    Lim, Ruth P.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (10): : 2017 - 2025
  • [43] Normal myocardial native T1 values in children using single-point saturation recovery and modified look-locker inversion recovery (MOLLI)
    Burkhardt, Barbara Elisabeth Ursula
    Menghini, Cristina
    Ruecker, Beate
    Kellenberger, Christian Johannes
    Buechel, Emanuela Regina Valsangiacomo
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (03) : 897 - 903
  • [44] Inversion Group (IG) Fitting: A New T1 Mapping Method for Modified Look-Locker Inversion Recovery (MOLLI) That Allows Arbitrary Inversion Groupings and Rest Periods (Including no Rest Period)
    Sussman, Marshall S.
    Yang, Issac Y.
    Fok, Kai-Ho
    Wintersperger, Bernd J.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (06) : 2332 - 2340
  • [45] Accuracy of T1 measurement with 3-D Look-Locker technique for dGEMRIC
    Li, Wei
    Scheidegger, Rachel
    Wu, Ying
    Vu, Anthony
    Prasad, Pottumarthi V.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (03) : 678 - 682
  • [46] A fast 3D Look-Locker method for volumetric T1 mapping
    Henderson, E
    McKinnon, G
    Lee, TY
    Rutt, BK
    MAGNETIC RESONANCE IMAGING, 1999, 17 (08) : 1163 - 1171
  • [47] Comparison of look-locker and MOLLI sequences for T1 mapping in hypertrophic and ischemic cardiomyopathy
    Xiaopeng Zhou
    Melanie Traughber
    Prabhakar Rajiah
    Deborah Kwon
    Paul Schoenhagen
    Scott D Flamm
    Randolph Setser
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [48] Shortened modified look-locker inversion recovery for myocardial T1 mapping in healthy volunteers: determination of reference T1 relaxation times at 3 Tesla MR according to different contrast injection methods
    Yon Mi Sung
    Hwanseok Yong
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [49] Fast High-Resolution T1 Mapping Using Inversion-Recovery Look-Locker Echo-Planar Imaging at Steady State: Optimization for Accuracy and Reliability
    Shin, Wanyong
    Gu, Hong
    Yang, Yihong
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (04) : 899 - 906
  • [50] A Model for Hepatic Fibrosis: The Competing Effects of Cell Loss and Iron on Shortened Modified Look-Locker Inversion Recovery T1 (shMOLLI-T1) in the Liver
    Tunnicliffe, Elizabeth M.
    Banerjee, Rajarshi
    Pavlides, Michael
    Neubauer, Stefan
    Robson, Matthew D.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (02) : 450 - 462