Modified look-locker inversion recovery T1 mapping indices: assessment of accuracy and reproducibility between magnetic resonance scanners

被引:59
|
作者
Raman, Fabio S. [1 ]
Kawel-Boehm, Nadine [1 ,2 ]
Gai, Neville [1 ]
Freed, Melanie [3 ]
Han, Jing [4 ]
Liu, Chia-Ying [1 ]
Lima, Joao A. C. [5 ]
Bluemke, David A. [1 ,6 ]
Liu, Songtao [1 ,6 ]
机构
[1] NIH, Ctr Clin, Bethesda, MD 20892 USA
[2] Univ Basel Hosp, Clin Radiol & Nucl Med, CH-4031 Basel, Switzerland
[3] NYU, Sch Med, New York, NY USA
[4] US FDA, Rockville, MD 20857 USA
[5] Johns Hopkins Univ, Sch Med, Div Cardiol, Baltimore, MD USA
[6] Natl Inst Biomed Imaging & Bioengn, Mol Biomed Imaging Lab, Bethesda, MD USA
基金
美国国家卫生研究院;
关键词
T1; mapping; Partition coefficient (lambda); Extracellular volume fraction (ECV); Diffuse myocardial fibrosis; Modified look-locker with inversion recovery (MOLLI); DIFFUSE MYOCARDIAL FIBROSIS; EXTRACELLULAR VOLUME FRACTION; INTRAINDIVIDUAL ASSESSMENT; GD-DTPA; VALIDATION; QUANTIFICATION; ASSOCIATION; RELAXATION; INFARCTION; SHMOLLI;
D O I
10.1186/1532-429X-15-64
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cardiovascular magnetic resonance (CMR) T1 mapping indices, such as T1 time and partition coefficient (lambda), have shown potential to assess diffuse myocardial fibrosis. The purpose of this study was to investigate how scanner and field strength variation affect the accuracy and precision/reproducibility of T1 mapping indices. Methods: CMR studies were performed on two 1.5T and three 3T scanners. Eight phantoms were made to mimic the T1/T2 of pre- and post-contrast myocardium and blood at 1.5T and 3T. T1 mapping using MOLLI was performed with simulated heart rate of 40-100 bpm. Inversion recovery spin echo (IR-SE) was the reference standard for T1 determination. Accuracy was defined as the percent error between MOLLI and IR-SE, and scan/re-scan reproducibility was defined as the relative percent mean difference between repeat MOLLI scans. Partition coefficient was estimated by Delta R1myocardium phantom/Delta R1blood phantom. Generalized linear mixed model was used to compare the accuracy and precision/reproducibility of T1 and lambda across field strength, scanners, and protocols. Results: Field strength significantly affected MOLLI T1 accuracy (6.3% error for 1.5T vs. 10.8% error for 3T, p<0.001) but not lambda accuracy (8.8% error for 1.5T vs. 8.0% error for 3T, p=0.11). Partition coefficients of MOLLI were not different between two 1.5T scanners (47.2% vs. 47.9%, p=0.13), and showed only slight variation across three 3T scanners (49.2% vs. 49.8% vs. 49.9%, p=0.016). Partition coefficient also had significantly lower percent error for precision (better scan/re-scan reproducibility) than measurement of individual T1 values (3.6% for lambda vs. 4.3%-4.8% for T1 values, approximately, for pre/post blood and myocardium values). Conclusion: Based on phantom studies, T1 errors using MOLLI ranged from 6-14% across various MR scanners while errors for partition coefficient were less (6-10%). Compared with absolute T1 times, partition coefficient showed less variability across platforms and field strengths as well as higher precision.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Systolic modified Look-Locker inversion recovery myocardial T1 mapping improves the accuracy of T1 and extracellular volume fraction measurements of patients with high heart rate or atrial fibrillation
    Shinbo, Hirohiko
    Tomioka, Satoshi
    Ino, Toshihiko
    Koyama, Keiko
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (04) : 405 - 413
  • [22] Evaluation of Modified Look-Locker Inversion Recovery and Arrhythmia-Insensitive Rapid Cardiac T1 Mapping Pulse Sequences in Cardiomyopathy Patients
    Robison, Sean
    Hong, KyungPyo
    Kim, Daniel
    Lloyd, Rachel
    Ramchand, Jay
    Hornsey, Emma
    Srivastava, Piyush
    Smith, Gerard
    Kearney, Leighton
    Lim, Ruth
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (05) : 732 - 738
  • [23] Native and Gd-EOB-DTPA-Enhanced T1 mapping for Assessment of Liver Fibrosis in NAFLD: Comparative Analysis of Modified Look-Locker Inversion Recovery and Water-specific T1 mapping
    Yang, Ru
    Peng, Hao
    Pan, Jing
    Wan, Qian
    Zou, Chao
    Hu, Fubi
    ACADEMIC RADIOLOGY, 2025, 32 (01) : 170 - 179
  • [24] Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart
    Messroghli, Daniel R.
    Greiser, Andreas
    Froehlich, Mirko
    Dietz, Rainer
    Schulz-Menger, Jeanette
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) : 1081 - 1086
  • [25] Effect of changes to Modified Look-Locker Inversion (MOLLI) sequence on T1 Mapping at 3.0 Tesla in healthy volunteers
    Adam K McDiarmid
    David M Higgins
    David P Ripley
    Akhlaque Uddin
    Ananth Kidambi
    Peter P Swoboda
    Tarique A Musa
    Bara Erhayiem
    John P Greenwood
    Sven Plein
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [26] Model-Based Acceleration of Look-Locker T1 Mapping
    Tran-Gia, Johannes
    Wech, Tobias
    Bley, Thorsten
    Koestler, Herbert
    PLOS ONE, 2015, 10 (04):
  • [27] Using Variable Flip Angle (VFA) and Modified Look-Locker Inversion Recovery (MOLLI) T1 mapping in clinical OE-MRI
    Bluemke, Emma
    Bertrand, Ambre
    Chu, Kwun-Ye
    Syed, Nigar
    Murchison, Andrew G.
    Cooke, Rosie
    Greenhalgh, Tessa
    Burns, Brian
    Craig, Martin
    Taylor, Nia
    Shah, Ketan
    Gleeson, Fergus
    Bulte, Daniel
    MAGNETIC RESONANCE IMAGING, 2022, 89 : 92 - 99
  • [28] Z-score mapping for standardized analysis and reporting of cardiovascular magnetic resonance modified Look-Locker inversion recovery (MOLLI) T1 data: Normal behavior and validation in patients with amyloidosis
    Kranzusch, Riccardo
    Aus Dem Siepen, Fabian
    Wiesemann, Stephanie
    Zange, Leonora
    Jeuthe, Sarah
    Ferreira da Silva, Tiago
    Kuehne, Titus
    Pieske, Burkert
    Tillmanns, Christoph
    Friedrich, Matthias G.
    Schulz-Menger, Jeanette
    Messroghli, Daniel R.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [29] Temporal registration: a new approach to manage the incomplete recovery of the longitudinal magnetization in the Modified Look-Locker Inversion Recovery sequence (MOLLI) for T1 mapping of the heart
    Habib Rebbah
    Thierry Galas
    Gilles Soulat
    Nadjia Kachenoura
    Anne Menini
    Charles A. Cuenod
    Elie Mousseaux
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2020, 33 : 569 - 580
  • [30] MRI Dixon Fat-Corrected Look-Locker T1 Mapping for Quantification of Liver Fibrosis and Inflammation-A Comparison With the Non-Fat-Corrected Shortened Modified Look-Locker Inversion Recovery Technique
    Klaus, Jeremias Bendicht
    Goerke, Ute
    Klarhofer, Markus
    Keerthivasan, Mahesh Bharath
    Jung, Bernd
    Berzigotti, Annalisa
    Ebner, Lukas
    Roos, Justus
    Christe, Andreas
    Obmann, Verena Carola
    Huber, Adrian Thomas
    INVESTIGATIVE RADIOLOGY, 2024, 59 (11) : 754 - 760