Quantitative assessment of hepatic function: modified look-locker inversion recovery (MOLLI) sequence for T1 mapping on Gd-EOB-DTPA-enhanced liver MR imaging

被引:74
|
作者
Yoon, Jeong Hee [1 ]
Lee, Jeong Min [1 ,2 ]
Paek, Munyoung [3 ]
Han, Joon Koo [1 ,2 ]
Choi, Byung Ihn [1 ,2 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Inst Radiat Med, 101 Daehak Ro, Seoul 110744, South Korea
[3] Siemens Healthcare, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
T1; map; Gadoxetic acid; Magnetic resonance imaging; MOLLI; Liver function estimation; HEPATOBILIARY SCINTIGRAPHY; NONINVASIVE DIAGNOSIS; PORTAL-HYPERTENSION; MAGNETIC-RESONANCE; CONTRAST AGENTS; RELAXATION-TIME; MYOCARDIAL T1; CIRRHOSIS; ELASTOGRAPHY; BIOMARKERS;
D O I
10.1007/s00330-015-3994-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To determine whether multislice T1 mapping of the liver using a modified look-locker inversion recovery (MOLLI) sequence on gadoxetic acid-enhanced magnetic resonance imaging (MRI) can be used as a quantitative tool to estimate liver function and predict the presence of oesophageal or gastric varices. Phantoms filled with gadoxetic acid were scanned three times using MOLLI sequence to test repeatability. Patients with chronic liver disease or liver cirrhosis who underwent gadoxetic acid-enhanced liver MRI including MOLLI sequence at 3 T were included (n = 343). Pre- and postcontrast T1 relaxation times of the liver (T1liver), changes between pre- and postcontrast T1liver (Delta T1liver), and adjusted postcontrast T1liver (postcontrast T1liver-T1spleen/T1spleen) were compared among Child-Pugh classes. In 62 patients who underwent endoscopy, all T1 parameters and spleen sizes were correlated with varices. Phantom study showed excellent repeatability of MOLLI sequence. As Child-Pugh scores increased, pre- and postcontrast T1liver were significantly prolonged (P < 0.001), and Delta T1liver and adjusted postcontrast T1liver decreased (P < 0.001). Adjusted postcontrast T1liver and spleen size were independently associated with varices (R (2) = 0.29, P < 0.001). T1 mapping of the liver using MOLLI sequence on gadoxetic acid-enhanced MRI demonstrated potential in quantitatively estimating liver function, and adjusted postcontrast T1liver was significantly associated with varices. aEuro cent T1 mapping using MOLLI sequence can be achieved within a breath-hold. aEuro cent T1liver measured by MOLLI sequence provided excellent short-term repeatability. aEuro cent Precontrast and postcontrast T1liver were significantly prolonged as Child-Pugh scores increased. aEuro cent Adjusted postcontrast T1liver and spleen size were independently associated with varices.
引用
收藏
页码:1775 / 1782
页数:8
相关论文
共 50 条
  • [1] Quantitative assessment of hepatic function: modified look-locker inversion recovery (MOLLI) sequence for T1 mapping on Gd-EOB-DTPA-enhanced liver MR imaging
    Jeong Hee Yoon
    Jeong Min Lee
    Munyoung Paek
    Joon Koo Han
    Byung Ihn Choi
    European Radiology, 2016, 26 : 1775 - 1782
  • [2] Native and Gd-EOB-DTPA-Enhanced T1 mapping for Assessment of Liver Fibrosis in NAFLD: Comparative Analysis of Modified Look-Locker Inversion Recovery and Water-specific T1 mapping
    Yang, Ru
    Peng, Hao
    Pan, Jing
    Wan, Qian
    Zou, Chao
    Hu, Fubi
    ACADEMIC RADIOLOGY, 2025, 32 (01) : 170 - 179
  • [3] Feasibility of Imaging-Based Quantitative Hepatic Function Assessment: Gd-EOB-DTPA-Enhanced Liver MR Imaging Combined with T1 Mapping
    Dong, Zhi
    Wang, Meng
    Feng, Yanqing
    Cai, Huasong
    Feng, Shi-Ting
    Li, Zi-Ping
    Lin, Zhi
    Peng, Zhenpeng
    CURRENT MEDICAL IMAGING, 2023, 19 (12) : 1394 - 1403
  • [4] Assessment of the evaluation of liver T1 mapping imaging applying virtual ECG gating on a modified look-locker inversion recovery (MOLLI) pulse sequence
    Yu, Seung-Man
    Goo, Eun-Hoe
    Lee, Suk-Jun
    Choe, Bo-Young
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (07) : 1142 - 1148
  • [5] Assessment of the evaluation of liver T1 mapping imaging applying virtual ECG gating on a modified look-locker inversion recovery (MOLLI) pulse sequence
    Seung-Man Yu
    Eun-Hoe Goo
    Suk-Jun Lee
    Bo-Young Choe
    Journal of the Korean Physical Society, 2014, 65 : 1142 - 1148
  • [6] Effects of heart rate in modified look-locker inversion recovery (MOLLI) T1 mapping
    Yoshinori Suizuki
    Kunihiko Teraoka
    Yoshiaki Komori
    Andreas Greiser
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [7] Fast calculation software for modified Look-Locker inversion recovery (MOLLI) T1 mapping
    Yoon-Chul Kim
    Khu Rai Kim
    Hyelee Lee
    Yeon Hyeon Choe
    BMC Medical Imaging, 21
  • [8] Fast calculation software for modified Look-Locker inversion recovery (MOLLI) T1 mapping
    Kim, Yoon-Chul
    Kim, Khu Rai
    Lee, Hyelee
    Choe, Yeon Hyeon
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [9] A segmented modified look-locker inversion recovery (MOLLI) sequence for high heart rate T1 mapping of mice
    Maryam Nezafat
    Markus Henningsson
    Christian Stehning
    Mehmet Akcakaya
    Andrea Protti
    Rene Botnar
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [10] Modified Look-Locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart
    Messroghli, DR
    Radjenovic, A
    Kozerke, S
    Higgins, DM
    Sivananthan, MU
    Ridgway, JP
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) : 141 - 146