Quantitative assessment of hepatic function: modified look-locker inversion recovery (MOLLI) sequence for T1 mapping on Gd-EOB-DTPA-enhanced liver MR imaging

被引:74
|
作者
Yoon, Jeong Hee [1 ]
Lee, Jeong Min [1 ,2 ]
Paek, Munyoung [3 ]
Han, Joon Koo [1 ,2 ]
Choi, Byung Ihn [1 ,2 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Inst Radiat Med, 101 Daehak Ro, Seoul 110744, South Korea
[3] Siemens Healthcare, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
T1; map; Gadoxetic acid; Magnetic resonance imaging; MOLLI; Liver function estimation; HEPATOBILIARY SCINTIGRAPHY; NONINVASIVE DIAGNOSIS; PORTAL-HYPERTENSION; MAGNETIC-RESONANCE; CONTRAST AGENTS; RELAXATION-TIME; MYOCARDIAL T1; CIRRHOSIS; ELASTOGRAPHY; BIOMARKERS;
D O I
10.1007/s00330-015-3994-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To determine whether multislice T1 mapping of the liver using a modified look-locker inversion recovery (MOLLI) sequence on gadoxetic acid-enhanced magnetic resonance imaging (MRI) can be used as a quantitative tool to estimate liver function and predict the presence of oesophageal or gastric varices. Phantoms filled with gadoxetic acid were scanned three times using MOLLI sequence to test repeatability. Patients with chronic liver disease or liver cirrhosis who underwent gadoxetic acid-enhanced liver MRI including MOLLI sequence at 3 T were included (n = 343). Pre- and postcontrast T1 relaxation times of the liver (T1liver), changes between pre- and postcontrast T1liver (Delta T1liver), and adjusted postcontrast T1liver (postcontrast T1liver-T1spleen/T1spleen) were compared among Child-Pugh classes. In 62 patients who underwent endoscopy, all T1 parameters and spleen sizes were correlated with varices. Phantom study showed excellent repeatability of MOLLI sequence. As Child-Pugh scores increased, pre- and postcontrast T1liver were significantly prolonged (P < 0.001), and Delta T1liver and adjusted postcontrast T1liver decreased (P < 0.001). Adjusted postcontrast T1liver and spleen size were independently associated with varices (R (2) = 0.29, P < 0.001). T1 mapping of the liver using MOLLI sequence on gadoxetic acid-enhanced MRI demonstrated potential in quantitatively estimating liver function, and adjusted postcontrast T1liver was significantly associated with varices. aEuro cent T1 mapping using MOLLI sequence can be achieved within a breath-hold. aEuro cent T1liver measured by MOLLI sequence provided excellent short-term repeatability. aEuro cent Precontrast and postcontrast T1liver were significantly prolonged as Child-Pugh scores increased. aEuro cent Adjusted postcontrast T1liver and spleen size were independently associated with varices.
引用
收藏
页码:1775 / 1782
页数:8
相关论文
共 50 条
  • [21] Quantitative assessment of hepatic fibrosis in chronic hepatitis B and C: T1 mapping on Gd-EOB-DTPA-enhanced liver magnetic resonance imaging
    Shen Pan
    Xiao-Qi Wang
    Qi-yong Guo
    World Journal of Gastroenterology, 2018, (18) : 2024 - 2035
  • [22] Usefulness of T1 mapping on Gd-EOB-DTPA-enhanced MR imaging in assessment of non-alcoholic fatty liver disease
    Ying Ding
    Sheng-Xiang Rao
    Tao Meng
    Caizhong Chen
    Renchen Li
    Meng-Su Zeng
    European Radiology, 2014, 24 : 959 - 966
  • [23] Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart
    Messroghli, Daniel R.
    Greiser, Andreas
    Froehlich, Mirko
    Dietz, Rainer
    Schulz-Menger, Jeanette
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (04) : 1081 - 1086
  • [24] Assessment of liver fibrosis using T1 mapping on Gd-EOB-DTPA-enhanced magnetic resonance
    Sheng, Ruo Fan
    Wang, He Qing
    Yang, Li
    Jin, Kai Pu
    Xie, Yan Hong
    Fu, Cai Xia
    Zeng, Meng Su
    DIGESTIVE AND LIVER DISEASE, 2017, 49 (07) : 789 - 795
  • [25] Temporal registration: a new approach to manage the incomplete recovery of the longitudinal magnetization in the Modified Look-Locker Inversion Recovery sequence (MOLLI) for T1 mapping of the heart
    Habib Rebbah
    Thierry Galas
    Gilles Soulat
    Nadjia Kachenoura
    Anne Menini
    Charles A. Cuenod
    Elie Mousseaux
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2020, 33 : 569 - 580
  • [26] Accuracy, Precision, and Reproducibility of Myocardial T1 Mapping: A Comparison of Four T1 Estimation Algorithms for Modified Look-Locker Inversion Recovery (MOLLI)
    Shao, Jiaxin
    Liu, Dapeng
    Sung, Kyunghyun
    Kim-Lien Nguyen
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 1746 - 1756
  • [27] Influence of Fat on Liver T1 Measurements Using Modified Look-Locker Inversion Recovery (MOLLI) Methods at 3T
    Mozes, Ferenc E.
    Tunnicliffe, Elizabeth M.
    Pavlides, Michael
    Robson, Matthew D.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (01) : 105 - 111
  • [28] Assessing liver function in patients with HBV-related HCC: a comparison of T1 mapping on Gd-EOB-DTPA-enhanced MR imaging with DWI
    Ding, Ying
    Rao, Sheng-Xiang
    Chen, Caizhong
    Li, Renchen
    Zeng, Meng-Su
    EUROPEAN RADIOLOGY, 2015, 25 (05) : 1392 - 1398
  • [29] Assessing liver function in patients with HBV-related HCC: a comparison of T1 mapping on Gd-EOB-DTPA-enhanced MR imaging with DWI
    Ying Ding
    Sheng-Xiang Rao
    Caizhong Chen
    Renchen Li
    Meng-Su Zeng
    European Radiology, 2015, 25 : 1392 - 1398
  • [30] Validation of the shortened modified look locker inversion recovery (Sh-MOLLI) sequence for cardiac gated T1 mapping
    Piechnik S.K.
    Ferreira V.M.
    Dall'Armellina E.
    Neubauer S.
    Robson M.D.
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)