Performance of an active fixation bipolar left ventricular lead vs passive fixation quadripolar leads in cardiac resynchronization therapy, a randomized trial

被引:4
|
作者
Keilegavlen, Havard [1 ,2 ]
Schuster, Peter [1 ,2 ]
Hovstad, Thomas [1 ]
Faerestrand, Svein [1 ,2 ]
机构
[1] Haukeland Hosp, Dept Heart Dis, Pb 1400, N-5021 Bergen, Norway
[2] Univ Bergen, Dept Clin Sci, Bergen, Norway
关键词
biventricular pacemaker; cardiac resynchronization therapy; heart failure; PLACEMENT; POSITION; DYSSYNCHRONY; IMPLANTATION; MORTALITY; SURVIVAL; SITES;
D O I
10.1002/joa3.12450
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Usage of active fixation bipolar left ventricular (LV) leads represents an alternative approach to the more commonly used passive fixation quadripolar leads in cardiac resynchronization therapy (CRT). We compared a bipolar LV lead with a side screw for active fixation and passive fixation quadripolar LV leads. Methods: Sixty-two patients were before CRT implantations randomly allocated to receive a bipolar (n = 31) or quadripolar (n = 31) LV leads. Speckle-tracking radial strain echocardiography was used to define the LV segment with latest mechanical activation as the target LV segment. The electrophysiological measurements and the capability to obtain a proximal position in a coronary vein placed over the target segment were assessed. Results: Upon implantation, the quadripolar lead demonstrated a lower pacing capture threshold than the bipolar lead, but at follow-up, there was no difference. There were no differences in the LV lead implant times or radiation doses. The success rate in reaching the target location was not significantly different between the two LV leads. Conclusions: The pacing capture thresholds were low, with no significant difference between active fixation bipolar leads and quadripolar leads. Active fixation leads did not promote a more proximal location of the stimulating electrode or a higher grade of concordance to the target segment than passive fixation leads.
引用
收藏
页码:212 / 218
页数:7
相关论文
共 50 条
  • [21] Performance of a novel left ventricular lead with short bipolar spacing for cardiac resynchronization therapy: Primary results of the Attain Performa Quadripolar Left Ventricular Lead Study
    Crossley, George H.
    Biffi, Mauro
    Johnson, Ben
    Lin, Albert
    Gras, Daniel
    Hussin, Azlan
    Cuffio, Allen
    Collier, Jack L.
    El-Chami, Mikhael
    Li, Shelby
    Holloman, Keith
    Exner, Derek V.
    HEART RHYTHM, 2015, 12 (04) : 751 - 758
  • [22] Results of patients with cardiac resynchronization therapy using a quadripolar left ventricular lead
    D'Ortencio, Alfredo
    Bevacqua, Raul J.
    INSUFICIENCIA CARDIACA, 2013, 8 (03) : 142 - 148
  • [23] The Use of Quadripolar Left Ventricular Leads Improves the Hemodynamic Response to Cardiac Resynchronization Therapy
    Osca, Joaquin
    Alonso, Pau
    Cano, Oscar
    Miguel Sanchez, Juan
    Tejada, David
    Andres, Ana
    Sancho Tello, Maria Jose
    Olaguee, Jose
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (03): : 326 - 333
  • [24] Impact of unipolar vs bipolar left ventricular pacing using a quadripolar lead on heart failure hospitalization in patients undergoing cardiac resynchronization therapy
    Mittal, S.
    Stivland, T.
    Wold, N.
    Hammill, E.
    Stein, K. M.
    EUROPEAN HEART JOURNAL, 2019, 40 : 2398 - 2398
  • [25] Outcome of Patients Treated by Cardiac Resynchronization Therapy Using a Quadripolar Left Ventricular Lead
    Bencardino, Gianluigi
    Di Monaco, Antonio
    Russo, Eleonora
    Colizzi, Cristian
    Perna, Francesco
    Pelargonio, Gemma
    Narducci, Maria Lucia
    Gabrielli, Francesca Augusta
    Lanza, Gaetano Antonio
    Rebuzzi, Antonio Giuseppe
    Crea, Filippo
    CIRCULATION JOURNAL, 2016, 80 (03) : 613 - 618
  • [26] Heart failure clinical outcomes after cardiac resynchronization with quadripolar versus bipolar left ventricular leads
    Mariana Martinho, M.
    Grade Santos, J.
    Ferreira, B.
    Almeida, S.
    Miranda, R.
    Cale, R.
    Santos Cunha, D.
    Mirinha Luz, J.
    Ilchyshyn, N.
    Baltazar, O.
    Budzak, K.
    Briosa, A.
    Sebaiti, D.
    Brandao Alves, L.
    Pereira, H.
    EUROPEAN JOURNAL OF HEART FAILURE, 2023, 25 : 12 - 12
  • [27] Transvenous extraction and reimplantation procedures for quadripolar left ventricular leads with an active fixation side helix
    Nomura, Takehiro
    Isawa, Tsuyoshi
    Toyoda, Shigeru
    Yamashita, Kennosuke
    Honda, Taku
    JOURNAL OF ARRHYTHMIA, 2024, 40 (05) : 1206 - 1209
  • [28] A comparison of the different features of quadripolar left ventricular pacing leads to deliver cardiac resynchronization therapy
    Antoniadis, Antonios P.
    Behar, Jonathan M.
    Sieniewicz, Ben
    Gould, Justin
    Niederer, Steven
    Rinaldi, Christopher A.
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (09) : 697 - 706
  • [29] Implant Characteristics of Quadripolar and Bipolar Left Ventricular Leads for Cardiac Resynchronization Therapy Results from the Attain Success Japan Study
    Ando, Kenji
    Kanda, Shigetaka
    Miura, Fumiharu
    Ashikaga, Keiichi
    Ehara, Natsuhiko
    Sakai, Yoshiaki
    Furukawa, Toshihito
    Yoshimura, Hiroyuki
    Adachi, Kazumasa
    INTERNATIONAL HEART JOURNAL, 2018, 59 (05) : 1002 - 1007
  • [30] LEFT VENTRICULAR LEAD RELATED COMPLICATIONS IN QUADRIPOLAR VERSUS BIPOLAR LEADS
    Rijal, Shasank
    Wolfe, Jonathan
    Althouse, Andrew
    Rattan, Rohit
    Jain, Sandeep
    Saba, Samir
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 697 - 697