Performance of an active fixation bipolar left ventricular lead vs passive fixation quadripolar leads in cardiac resynchronization therapy, a randomized trial

被引:4
|
作者
Keilegavlen, Havard [1 ,2 ]
Schuster, Peter [1 ,2 ]
Hovstad, Thomas [1 ]
Faerestrand, Svein [1 ,2 ]
机构
[1] Haukeland Hosp, Dept Heart Dis, Pb 1400, N-5021 Bergen, Norway
[2] Univ Bergen, Dept Clin Sci, Bergen, Norway
关键词
biventricular pacemaker; cardiac resynchronization therapy; heart failure; PLACEMENT; POSITION; DYSSYNCHRONY; IMPLANTATION; MORTALITY; SURVIVAL; SITES;
D O I
10.1002/joa3.12450
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Usage of active fixation bipolar left ventricular (LV) leads represents an alternative approach to the more commonly used passive fixation quadripolar leads in cardiac resynchronization therapy (CRT). We compared a bipolar LV lead with a side screw for active fixation and passive fixation quadripolar LV leads. Methods: Sixty-two patients were before CRT implantations randomly allocated to receive a bipolar (n = 31) or quadripolar (n = 31) LV leads. Speckle-tracking radial strain echocardiography was used to define the LV segment with latest mechanical activation as the target LV segment. The electrophysiological measurements and the capability to obtain a proximal position in a coronary vein placed over the target segment were assessed. Results: Upon implantation, the quadripolar lead demonstrated a lower pacing capture threshold than the bipolar lead, but at follow-up, there was no difference. There were no differences in the LV lead implant times or radiation doses. The success rate in reaching the target location was not significantly different between the two LV leads. Conclusions: The pacing capture thresholds were low, with no significant difference between active fixation bipolar leads and quadripolar leads. Active fixation leads did not promote a more proximal location of the stimulating electrode or a higher grade of concordance to the target segment than passive fixation leads.
引用
收藏
页码:212 / 218
页数:7
相关论文
共 50 条
  • [41] Active fixation of bipolar left ventricular lead through a persistent left superior vena cava
    Nicolis, Daniele
    Mugnai, Giacomo
    Pepi, Patrizia
    Ribichini, Flavio Luciano
    Lettieri, Corrado
    JOURNAL OF ARRHYTHMIA, 2022, 38 (03) : 488 - 490
  • [42] The Comparison between the Active-fixation Leads and Passive-fixation Leads in Right Ventricular Pacing
    Yu, H. B.
    Wang, D. M.
    Zang, H. Y.
    Tian, Y.
    Zhang, D. H.
    Han, Y. L.
    CARDIOLOGY, 2009, 114 : 34 - 34
  • [43] Comparison Between Active-Fixation Leads and Passive-Fixation Leads in Right Ventricular Pacing
    Yu, Haibo
    Wang, Dongmei
    Zang, Hongyun
    Tian, Yun
    Zhang, Donghong
    Han, Yaling
    CIRCULATION, 2010, 122 (02) : E310 - E310
  • [44] The Comparison between the Active-Fixation Leads and Passive-Fixation Leads in Right Ventricular Pacing
    Yu, H. B.
    Wang, D. M.
    Zang, H. Y.
    Tian, Y.
    Zhang, D. H.
    Han, Y. L.
    CARDIOLOGY, 2010, 117 : 38 - 39
  • [45] Active fixation leads vs passive fixation pacemaker leads, a two sided story of high sensitive cardiac troponine I elevation
    Karanikas, S.
    Margariti, C. M.
    Leontopoulou, V. L.
    Kontzinos, I.
    Koylali, F. K.
    Vrakas, P. V.
    Kotsiourou, E. K.
    Leventi, D. L.
    Loukopoulou, O. L.
    Nikolaou, N. N.
    EUROPEAN JOURNAL OF CARDIOVASCULAR NURSING, 2016, 15 : S37 - S37
  • [46] Non-invasive imaging of cardiac electrophysiology in a cardiac resynchronization therapy defibrillator patient with a quadripolar left ventricular lead
    Seger, Michael
    Hanser, Friedrich
    Dichtl, Wolfgang
    Stuehlinger, Markus
    Hintringer, Florian
    Trieb, Thomas
    Pfeifer, Bernhard
    Berger, Thomas
    EUROPACE, 2014, 16 (05): : 743 - 749
  • [47] Pressure-Volume Loop Analysis of Multipoint Pacing With a Quadripolar Left Ventricular Lead in Cardiac Resynchronization Therapy
    van Everdingen, Wouter M.
    Zweerink, Alwin
    Salden, Odette A. E.
    Cramer, Maarten J.
    Doevendans, Pieter A.
    Engels, Elien B.
    van Rossum, Albert C.
    Prinzen, Frits W.
    Vernooy, Kevin
    Allaart, Cornelis P.
    Meine, Mathias
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (07) : 881 - 889
  • [48] Coronary vein pacing with standard active fixation leads for cardiac resynchronization
    Menezes, Miguel Nobre
    De Sousa, Joao
    Marques, Pedro
    EUROPACE, 2015, 17 (10): : 1562 - 1562
  • [49] Occurrence of simultaneous cathodal-anodal capture with left ventricular quadripolar leads for cardiac resynchronization therapy: an electrocardiogram evaluation
    Occhetta, Eraldo
    Dell'Era, Gabriele
    Giubertoni, Ailia
    Magnani, Andrea
    Rametta, Francesco
    Blandino, Alessandro
    Magnano, Vincenzo
    Malacrida, Maurizio
    Marino, Paolo
    EUROPACE, 2017, 19 (04): : 596 - 601
  • [50] Optimization in cardiac resynchronization therapy with quadripolar leads offer improvement in cardiac energetics in heart failure patients compared with bipolar leads: HUMVEE Clinical Trial
    Antoniou, K.
    Chrysohoou, C.
    Dilaveris, P.
    Konstantinou, K.
    Manolakou, P.
    Xydis, P.
    Magkas, N.
    Antonakos, V
    Kakioris, K.
    Gatzoulis, K.
    Skiadas, I
    Tousoulis, D.
    EUROPEAN HEART JOURNAL, 2020, 41 : 888 - 888