A comparison of the different features of quadripolar left ventricular pacing leads to deliver cardiac resynchronization therapy

被引:5
|
作者
Antoniadis, Antonios P. [1 ]
Behar, Jonathan M.
Sieniewicz, Ben
Gould, Justin
Niederer, Steven
Rinaldi, Christopher A.
机构
[1] St Thomas Hosp, Guys & St Thomas NHS Fdn Trust, Cardiovasc Dept, 6th Floor East Wing,Westminster Bridge Rd, London SE1 7EH, England
基金
英国工程与自然科学研究理事会;
关键词
Quadripolar left ventricular leads; cardiac resynchronization therapy; heart failure; biventricular pacing; multisite pacing; PHRENIC-NERVE STIMULATION; CHRONIC HEART-FAILURE; ACUTE HEMODYNAMIC-RESPONSE; FOLLOW-UP; IMPLANTABLE DEFIBRILLATOR; MECHANICAL DYSSYNCHRONY; MULTISITE; IMPROVES; MULTICENTER; EXPERIENCE;
D O I
10.1080/17434440.2017.1369404
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: Cardiac Resynchronization therapy (CRT) improves the quality of life and reduces morbidity and mortality of certain patients with heart failure. However, not all patients respond positively after CRT and about one third of cases do not experience benefit. Suboptimal biventricular pacing may account for this and quadripolar left ventricular (LV) leads have emerged in the last years to address issues relating to inadequate delivery of CRT. Areas covered: This review article concisely summarizes the main technical characteristics of the quadripolar LV leads either currently available in the market today or under final stages of development. Focus is given in recent advancements in the area and challenging aspects and controversies, future implications as well as opportunities for further development. Expert commentary: Quadripolar LV pacing leads have now become the standard of care in CRT. Currently a multitude of lead options is available to the clinician. The selection process of the most appropriate lead is far from the 'one size fits all' concept. Further development of quadripolar LV leads is currently ongoing and it is anticipated to contribute towards the release of more technologically advantageous leads which will enable the delivery of optimal CRT therapy with the lowest rate of complications.
引用
收藏
页码:697 / 706
页数:10
相关论文
共 50 条
  • [1] Effective nonapical left ventricular pacing with quadripolar leads for cardiac resynchronization therapy
    Forleo, Giovanni B.
    Schiavone, Marco
    Della Rocca, Domenico
    Solimene, Francesco
    Schillaci, Vincenzo
    Covino, Gregorio
    Sassara, Massimo
    Savarese, Gianluca
    Donzelli, Stefano
    Badolati, Sandra
    Gerosa, Carmelo
    Lavalle, Carlo
    Gasperetti, Alessio
    Mitacchione, Gianfranco
    Lovecchio, Mariolina
    Valsecchi, Sergio
    Santini, Luca
    KARDIOLOGIA POLSKA, 2021, 79 (04) : 442 - 448
  • [2] Outcomes of cardiac resynchronization therapy using left ventricular quadripolar leads
    Yang, Mei
    Li, Xuping
    Liang, Jinjun
    Asirvatham, Samuel J.
    Espinosa, Raul
    Li, Yigang
    Friedman, Paul A.
    Cha, Yong-Mei
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (08): : 912 - 919
  • [3] Cardiac resynchronization therapy: a comparison among left ventricular bipolar, quadripolar and active fixation leads
    M. Ziacchi
    I. Diemberger
    A. Corzani
    C. Martignani
    A. Mazzotti
    G. Massaro
    C. Valzania
    C. Rapezzi
    G. Boriani
    M. Biffi
    Scientific Reports, 8
  • [4] Cardiac resynchronization therapy: a comparison among left ventricular bipolar, quadripolar and active fixation leads
    Ziacchi, M.
    Diemberger, I.
    Corzani, A.
    Martignani, C.
    Mazzotti, A.
    Massaro, G.
    Valzania, C.
    Rapezzi, C.
    Boriani, G.
    Biffi, M.
    SCIENTIFIC REPORTS, 2018, 8
  • [5] Effective non-apical left ventricular pacing with quadripolar leads for cardiac resynchronization therapy: a multicenter study
    Forleo, G. B.
    Panattoni, G.
    Solimene, F.
    Schillaci, V.
    Covino, G.
    Sassara, M.
    Savarese, G.
    Santini, L.
    Donzelli, S.
    Badolati, S.
    Gerosa, C.
    Valsecchi, S.
    Mangone, G.
    Sergi, D.
    EUROPEAN HEART JOURNAL, 2017, 38 : 1170 - 1170
  • [6] Comparing Effectiveness of Quadripolar and Bipolar Left Ventricular Leads in Cardiac Resynchronization Therapy
    Lee, Dustin
    Liu, Christopher
    Lerman, Bruce
    Markowitz, Steve
    Cheung, Jim
    Ip, James
    Thomas, George
    CIRCULATION, 2016, 134
  • [7] Comparing Effectiveness of Quadripolar and Bipolar Left Ventricular Leads in Cardiac Resynchronization Therapy
    Lee, Dustin
    Liu, Christopher
    Lerman, Bruce
    Markowitz, Steve
    Cheung, Jim
    Ip, James
    Thomas, George
    CIRCULATION, 2016, 134
  • [8] The clinical application of quadripolar left ventricular leads in cardiac resynchronization therapy patients
    Yu, Haibo
    Yan, Xiaolei
    Liang, Yanchun
    Xu, Baige
    Yang, Gao
    Liu, Rong
    Shuang, Wang
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (16) : C123 - C123
  • [9] The Use of Quadripolar Left Ventricular Leads Improves the Hemodynamic Response to Cardiac Resynchronization Therapy
    Osca, Joaquin
    Alonso, Pau
    Cano, Oscar
    Miguel Sanchez, Juan
    Tejada, David
    Andres, Ana
    Sancho Tello, Maria Jose
    Olaguee, Jose
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (03): : 326 - 333
  • [10] Bipolar versus quadripolar left ventricular leads for cardiac resynchronization therapy: evidence to date
    Fyenbo, Daniel Benjamin
    Frausing, Maria Hee Jung Park
    Kronborg, Mads Brix
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2021, 19 (12) : 1075 - 1084