Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures

被引:18
|
作者
Ma, Ji [1 ]
Zhao, Ziying [2 ]
Zhi, Xiaodong [1 ,3 ]
Wang, Hao [1 ,3 ]
Wang, Wei [1 ,3 ,4 ]
机构
[1] Jinzhou Med Univ, Dept Orthped, Affiliated Hosp 1, Jinzhou 121000, Liaoning Provin, Peoples R China
[2] Jinzhou Med Univ, Dept Endocrinol, Affiliated Hosp 1, Jinzhou 121000, Liaoning Provin, Peoples R China
[3] Liaoning Key Lab Med Tissue Engn, Jinzhou 121000, Liaoning Provin, Peoples R China
[4] Jinzhou Med Univ, Inst Orthped, Jinzhou 121000, Liaoning Provin, Peoples R China
关键词
Femoral neck fracture; Pauwels III type; Finite element analysis; Biomechanics; HIP SCREW; YOUNG-PATIENTS; ADULTS;
D O I
10.1186/s12891-022-06003-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Comparison of 4 cannulated lag screws (3 inverted triangular cannulated screws + anti-rotating screws;4 CLS), dynamic hip screws + derotational screws (DHS + DS), and femoral neck fixation system (FNS) in the treatment of Biomechanical properties of middle-aged Pauwels type III femoral neck fractures. Methods: The femur CT data of a healthy young volunteer was selected and imported into Mimics software to construct a three-dimensional model of a normal femur. Pauwels type III femoral neck fractures were simulated according to the 70 degrees fracture line. Use Geomagic and SolidWorks software to optimize and build CLS, DHS + DS, and FNS fracture internal fixation models. Finally, Ansys software was used to analyze the stress distribution, peak value, and maximum displacement of the proximal fracture fragment and internal fixation; the displacement distribution, and peak value of the fracture surface at the fracture end. Results: (1) The stress peaks of the proximal fracture fragments in the three groups were concentrated near the femoral calcar. The peak stress of the FNS group was the largest, and the DHS + DS group was the smallest.(2)The displacement of the fracture fragments was all located at the top of the femur. The peak displacement of the FNS group was the largest, and the DHS + DS group was the smallest.(3) The internal fixation stress of the three groups is concentrated in the middle part of the device. The stress distribution of the first two groups of models is more uniform than that of FNS. The peak stress of FNS is the largest and the CLS is the smallest.(4) The internal fixed displacements are all located at the top of the model. The peak displacement of the CLS is the largest, and the DHS + DS is the smallest. (5) The displacement of the fracture surface is in the upper part of the fractured end. The peak displacement of the FNS group was the largest, and the DHS + DS group was the smallest. Conclusion: Compared with the other two internal fixation methods, dynamic hip screw + derotational screw (DHS + DS) showed good biomechanical stability. When Pauwels type III femoral neck fracture occurs in young adults, DHS + DS can be given priority as the preferred treatment for this type of fracture.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: A biomechanical study
    Zhou, Lin
    Lin, Jiaming
    Huang, Anfei
    Gan, Weidong
    Zhai, Xu
    Sun, Kai
    Huang, Shiqing
    Li, Zhizhong
    CLINICAL BIOMECHANICS, 2020, 74 : 103 - 110
  • [32] Results of Internal Fixation of Pauwels Type-3 Vertical Femoral Neck Fractures
    Parker, Martyn J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (02): : 490 - 491
  • [33] Results of internal fixation of Pauwels type-3 vertical femoral neck fractures
    Liporace, Frank
    Gaines, Robert
    Collinge, Cory
    Haidukewych, George J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (08): : 1654 - 1659
  • [34] Finite element analysis of different internal fixation methods for the treatment of atrophic mandible fractures
    Kahveci, Kadircan
    Ayranci, Ferhat
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2023, 124 (01)
  • [35] Comparison of different internal fixation implants in the treatment of talar neck fractures: A finite element analysis
    Fu, Xin
    Cao, Hong-Bin
    Li, Nan
    Wang, Gui-Xin
    He, Jin-Quan
    JOINT DISEASES AND RELATED SURGERY, 2024, 35 (01): : 27 - 35
  • [36] Mechanical effects of surgical variations in the femoral neck system on Pauwels type III femoral neck fracture A FINITE ELEMENT ANALYSIS
    Jung, C-H
    Cha, Y.
    Yoon, H. S.
    Park, C. H.
    Yoo, J-, I
    Kim, J-T
    Jeon, Y.
    BONE & JOINT RESEARCH, 2022, 11 (02): : 102 - 111
  • [37] Results of Internal Fixation of Pauwels Type-3 Vertical Femoral Neck Fractures Reply
    Haidukewych, George J.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (02): : 491 - 491
  • [38] A model to evaluate Pauwels type III femoral neck fractures
    Magone, Kevin M.
    Owen, Jonas K.
    Kemker, Bernard P.
    Bloom, Oliver
    Martin, Sidney
    Atkinson, Patrick
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2018, 232 (03) : 310 - 317
  • [39] Comparison of three different internal fixation methods in the treatment of femoral neck fracture
    Zhang, Xinzhao
    Zheng, Changling
    Huang, Jin
    Chen, Hui
    Lei, Jie
    Huang, Cong
    HELIYON, 2024, 10 (14)
  • [40] Proposal for a New Fixation Method for Pauwels Type III Femoral Neck Fracture-Metaphyseal Stem: A Finite-Element Analysis
    Anderson Freitas
    Fabrício Reichert Barin
    Leonardo Rigobello Battaglion
    Hélio Ismael da Costa
    Eduardo Duarte Santos
    Hugo Amando Rosado
    Marcos Giordano
    Vincenzo Giordano
    Antonio Carlos Shimano
    Indian Journal of Orthopaedics, 2021, 55 : 378 - 384