Finite element comparative analysis of three different internal fixation methods in the treatment of Pauwels type III femoral neck fractures

被引:18
|
作者
Ma, Ji [1 ]
Zhao, Ziying [2 ]
Zhi, Xiaodong [1 ,3 ]
Wang, Hao [1 ,3 ]
Wang, Wei [1 ,3 ,4 ]
机构
[1] Jinzhou Med Univ, Dept Orthped, Affiliated Hosp 1, Jinzhou 121000, Liaoning Provin, Peoples R China
[2] Jinzhou Med Univ, Dept Endocrinol, Affiliated Hosp 1, Jinzhou 121000, Liaoning Provin, Peoples R China
[3] Liaoning Key Lab Med Tissue Engn, Jinzhou 121000, Liaoning Provin, Peoples R China
[4] Jinzhou Med Univ, Inst Orthped, Jinzhou 121000, Liaoning Provin, Peoples R China
关键词
Femoral neck fracture; Pauwels III type; Finite element analysis; Biomechanics; HIP SCREW; YOUNG-PATIENTS; ADULTS;
D O I
10.1186/s12891-022-06003-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Comparison of 4 cannulated lag screws (3 inverted triangular cannulated screws + anti-rotating screws;4 CLS), dynamic hip screws + derotational screws (DHS + DS), and femoral neck fixation system (FNS) in the treatment of Biomechanical properties of middle-aged Pauwels type III femoral neck fractures. Methods: The femur CT data of a healthy young volunteer was selected and imported into Mimics software to construct a three-dimensional model of a normal femur. Pauwels type III femoral neck fractures were simulated according to the 70 degrees fracture line. Use Geomagic and SolidWorks software to optimize and build CLS, DHS + DS, and FNS fracture internal fixation models. Finally, Ansys software was used to analyze the stress distribution, peak value, and maximum displacement of the proximal fracture fragment and internal fixation; the displacement distribution, and peak value of the fracture surface at the fracture end. Results: (1) The stress peaks of the proximal fracture fragments in the three groups were concentrated near the femoral calcar. The peak stress of the FNS group was the largest, and the DHS + DS group was the smallest.(2)The displacement of the fracture fragments was all located at the top of the femur. The peak displacement of the FNS group was the largest, and the DHS + DS group was the smallest.(3) The internal fixation stress of the three groups is concentrated in the middle part of the device. The stress distribution of the first two groups of models is more uniform than that of FNS. The peak stress of FNS is the largest and the CLS is the smallest.(4) The internal fixed displacements are all located at the top of the model. The peak displacement of the CLS is the largest, and the DHS + DS is the smallest. (5) The displacement of the fracture surface is in the upper part of the fractured end. The peak displacement of the FNS group was the largest, and the DHS + DS group was the smallest. Conclusion: Compared with the other two internal fixation methods, dynamic hip screw + derotational screw (DHS + DS) showed good biomechanical stability. When Pauwels type III femoral neck fracture occurs in young adults, DHS + DS can be given priority as the preferred treatment for this type of fracture.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Proposal for a New Fixation Method for Pauwels Type III Femoral Neck Fracture-Metaphyseal Stem: A Finite-Element Analysis
    Freitas, Anderson
    Barin, Fabricio Reichert
    Battaglion, Leonardo Rigobello
    da Costa, Helio Ismael
    Santos, Eduardo Duarte
    Rosado, Hugo Amando
    Giordano, Marcos
    Giordano, Vincenzo
    Shimano, Antonio Carlos
    INDIAN JOURNAL OF ORTHOPAEDICS, 2021, 55 (SUPPL 2) : 378 - 384
  • [42] Proximal femoral bionic nail-a novel internal fixation system for the treatment of femoral neck fractures: a finite element analysis
    Ding, Kai
    Zhu, Yanbin
    Zhang, Yifan
    Li, Yonglong
    Wang, Haicheng
    Li, Jiaxing
    Chen, Wei
    Zhang, Qi
    Zhang, Yingze
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [43] Biomechanical analysis of various internal fracture fixation devices used for treating femoral neck fractures: A comparative finite element analysis
    Mahapatra, Biswajit
    Pal, Bidyut
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (10):
  • [44] Bio-mechanical effects of femoral neck system versus cannulated screws on treating young patients with Pauwels type III femoral neck fractures: a finite element analysis
    Fan, Xiao
    Zhou, Yimin
    Dai, Shiyou
    Lao, Kecheng
    Zhang, Qiliang
    Yu, Tengbo
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [45] Bio-mechanical effects of femoral neck system versus cannulated screws on treating young patients with Pauwels type III femoral neck fractures: a finite element analysis
    Xiao Fan
    Yimin Zhou
    Shiyou Dai
    Kecheng Lao
    Qiliang Zhang
    Tengbo Yu
    BMC Musculoskeletal Disorders, 25
  • [46] Nonanatomical reduction of femoral neck fractures in young patients with different Pauwels classifications: a retrospective study and finite element analysis
    Xiong, Binglang
    Cao, Xuhan
    Zhang, Cheng
    Wang, Shaoyu
    Sun, Xudong
    Guo, Ziyan
    Zhang, Qingwen
    Bai, Zixing
    Sun, Weidong
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [47] Biomechanical comparison of Gofried positive support reduction of Pauwels type III femoral neck fractures: A finite elements analysis
    Ding, Ming
    Su, Zhihao
    Wang, Daoyu
    Mo, Lan
    Mei, Jiong
    Sun, Wanju
    Li, Shuang
    Ni, Ming
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (12):
  • [48] Finite Element Analysis of Different Titanium Plates for Internal Fixation of Fractures of the Mandibular Condylar Neck
    Liokatis, Paris
    Tzortzinis, Georgios
    Gerasimidis, Simos
    Smolka, Wenko
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 79 (03) : 665.e1 - 665.e10
  • [49] Finite element analysis of different screw constructs in the treatment of unstable femoral neck fractures
    Li, Jiantao
    Wang, Menglin
    Zhou, Jianfeng
    Zhang, Hao
    Li, Lianting
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (04): : 995 - 1003
  • [50] Comparison of three different internal fixation implants in treatment of femoral neck fracture-a finite element analysis (vol 14, 76, 2019)
    Li, Jia
    Zhao, Zhe
    Yin, Pengbin
    Zhang, Licheng
    Tang, Peifu
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2019, 14