Bioanalysis without Sample Cleanup or Chromatography: The Evaluation and Initial Implementation of Direct Analysis in Real Time Ionization Mass Spectrometry for the Quantification of Drugs in Biological Matrixes

被引:169
|
作者
Yu, Shaoxia [1 ]
Crawford, Elizabeth [2 ]
Tice, Joe [2 ]
Musselman, Brian [2 ]
Wu, Jing-Tao [1 ]
机构
[1] Millennium Pharmaceut Inc, Dept Drug Metab & Pharmacokinet, Cambridge, MA 02139 USA
[2] IonSense Inc, Saugus, MA 01906 USA
关键词
LIQUID-CHROMATOGRAPHY; PLASMA; EXTRACTION; INJECTION; ION;
D O I
10.1021/ac801734t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two key bottlenecks in pharmaceutical bioanalysis are sample cleanup and chromatographic separations. Although multiple approaches have been developed in the past decade to either shorten or multiplex these steps, they remain the rate limiting steps as ADME (Absorption, Distribution, Metabolism, and Excretion) property screening is being routinely incorporated into the drug discovery process. In this work, a novel system incorporating an automated Direct Analysis in Real Time (DART) ionization source coupled with a triple-quadrupole mass spectrometer has been developed and evaluated for quantitative bioanalysis. This system has the capability of directly analyzing samples from their biological matrixes and therefore potentially eliminating the need for sample cleanup and chromatographic separations. A LEAP Technologies autosampler was customized to perform the automated sample introduction into the DART beam with high precision, which significantly improved the reproducibility of the method. Additional pumping was applied to the atmospheric pressure inlet on the mass spectrometer to compensate for the increased vacuum load because of the use of high-flow helium by the DART. This resulted in an improvement of detection sensitivity by a factor of 10 to 100 times. Matrix effects for a diversified class of compounds were evaluated directly from untreated raw plasma and were found to range from approximately 0.05 to 0.7. Precision and accuracy were also tested for multiple test compounds over a dynamic range of four orders of magnitude. The system has been used to analyze biological samples from both in vivo pharmacokinetic studies and in vitro microsomal/S9 stability studies, and the results generated were similar to those obtained with conventional LC/MS/MS methods. Overall, this new automated DART-triple quadrupole mass spectrometer system has demonstrated significant potential for high-throughput bioanalysis.
引用
收藏
页码:193 / 202
页数:10
相关论文
共 50 条
  • [21] Molecular data storage using direct analysis in real time (DART) ionization mass spectrometry for decoding
    Pardi-Toth, Veronika
    Kuki, Akos
    Kordovan, Marcell Arpad
    Roth, Gergo
    Nagy, Lajos
    Zsuga, Miklos
    Nagy, Tibor
    Keki, Sandor
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [22] Improved desorption/ionization and ion transmission in surface scanning by direct analysis in real time mass spectrometry
    Haebe, Tim T.
    Morlock, Gertrud E.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 (02) : 321 - 332
  • [23] Direct injection human plasma analysis for the quantification of antihypertensive drugs for therapeutic drug monitoring using hydrophilic interaction liquid chromatography/electrospray ionization mass spectrometry
    Meimaroglou, Stefanos
    Vonaparti, Ariadni
    Migias, George
    Gennimata, Dimitra
    Poulou, Sofia
    Panderi, Irene
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1004 : 1 - 9
  • [24] Mass Spectrometry-Sensitive Probes Coupled with Direct Analysis in Real Time for Simultaneous Sensing of Chemical and Biological Properties of Botanical Drugs
    Li, Zhenhao
    Wang, Yi
    Cheng, Yiyu
    ANALYTICAL CHEMISTRY, 2019, 91 (14) : 9001 - 9009
  • [25] Quantification of Endogenous Cholesterol in Human Serum on Paper Using Direct Analysis in Real Time Mass Spectrometry
    Hsieh, Hua-Yi
    Li, Li-Hua
    Hsu, Ren-Yu
    Kao, Wei-Fong
    Huang, Ying-Chen
    Hsu, Cheng-Chih
    ANALYTICAL CHEMISTRY, 2017, 89 (11) : 6147 - 6153
  • [26] Rapid screening and quantification of glucocorticoids in essential oils using direct analysis in real time mass spectrometry
    Zhang, Jialing
    Li, Ze
    Zhou, Zhigui
    Bai, Yu
    Liu, Huwei
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2016, 30 : 133 - 140
  • [27] Comparison of the Internal Energy Deposition of Direct Analysis in Real Time and Electrospray Ionization Time-of-Flight Mass Spectrometry
    Harris, Glenn A.
    Hostetler, Dana M.
    Hampton, Christina Y.
    Fernandez, Facundo M.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2010, 21 (05) : 855 - 863
  • [28] Rapid differentiation and quality control of tobacco products using Direct Analysis in Real Time Mass Spectrometry and Liquid Chromatography Mass Spectrometry
    Losso, Klemens
    Cardini, Julian
    Huber, Susanne
    Kappacher, Christoph
    Jakschitz, Thomas
    Rainer, Matthias
    Bonn, Gunther K.
    TALANTA, 2022, 238
  • [29] Wood Species Differentiation: A Comparative Study of Direct Analysis in Real-Time and Chromatography Mass Spectrometry
    Isak, Ilena
    Newson, Harriet Laura
    Singh, Tripti
    FORESTS, 2025, 16 (02):
  • [30] Investigations on the Coupling of High-Performance Liquid Chromatography to Direct Analysis in Real Time Mass Spectrometry
    Eberherr, Walter
    Buchberger, Wolfgang
    Hertsens, Robert
    Klampfl, Christian W.
    ANALYTICAL CHEMISTRY, 2010, 82 (13) : 5792 - 5796