Investigations on the Coupling of High-Performance Liquid Chromatography to Direct Analysis in Real Time Mass Spectrometry

被引:58
|
作者
Eberherr, Walter [1 ]
Buchberger, Wolfgang [1 ]
Hertsens, Robert [2 ]
Klampfl, Christian W. [1 ]
机构
[1] Johannes Kepler Univ Linz, Inst Analyt Chem, A-4040 Linz, Austria
[2] JEOL Europe BV, B-1930 Zaventem, Belgium
关键词
ATMOSPHERIC-PRESSURE PHOTOIONIZATION; MICELLAR ELECTROKINETIC CHROMATOGRAPHY; DESORPTION ELECTROSPRAY-IONIZATION; OF-FLIGHT; DRUGS;
D O I
10.1021/ac1008496
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel hyphenated technique namely the combination of HPLC with direct analysis in real time (DART) mass spectrometry (MS) is presented. The coupling of HPLC to DART-MS was achieved by a simple interface design with a capillary end piece transferring the HPLC effluent to the ionization region of the DART. Flow rates (0.3-1.6 mL min(-1)) and inner diameters of the capillary (50-150 mu m) were harmonized to provide a stable liquid jet. Ionization-related parameters optimized included positioning of the capillary end piece with respect to He outlet of the ionization source and the MS inlet, He heater temperature and He flow rate. Among DART-MS voltages, the grid electrode voltage proved to have the most pronounced effect on signal intensities. A major benefit of this setup is the possibility to employ (commonly not MS-compatible) HPLC eluents such as phosphate buffers up to a phosphate concentration of 120 mM even at typical HPLC flow rates such as 1 mL min(-1) and above without negative side effects like contamination of the ion source or ion suppression. Experiments evaluating the correlation of signal intensity to mass-flow and concentration revealed that DART-MS can be seen as a mass flow sensitive detector. The usability of this hyphenated technique has been tested on the example of four parabenes (measured in the negative ion mode) as well as a set of pyrazine derivatives (measured in the positive ion mode). For the parabenes limits of detection (LOD) in the range of 20-55 mu g L-1 and linear ranges from at least 200-10000 mu g L-1 with correlation coefficients better than 0.997 were obtained.
引用
收藏
页码:5792 / 5796
页数:5
相关论文
共 50 条
  • [1] High-performance liquid chromatography coupled to direct analysis in real time mass spectrometry: Investigations on gradient elution and influence of complex matrices on signal intensities
    Beissmann, Susanne
    Buchberger, Wolfgang
    Hertsens, Robert
    Klampfl, Christian W.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (31) : 5180 - 5186
  • [2] Coupling of planar chromatography with Direct Analysis in Real Time mass spectrometry
    Morlock, Gertrud E.
    Chernetsova, Elena S.
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2012, 10 (03): : 703 - 710
  • [3] COUPLING OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH MASS-SPECTROMETRY
    LEVSEN, K
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 333 (07): : 754 - 755
  • [4] New coupling of planar chromatography with direct analysis in real time mass spectrometry
    Morlock, Gertrud
    Ueda, Yoshihisa
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1143 (1-2) : 243 - 251
  • [5] A straightforward means of coupling preparative high-performance liquid chromatography and mass spectrometry
    Cai, H
    Kiplinger, JP
    Goetzinger, WK
    Cole, RO
    Laws, KA
    Foster, M
    Schrock, A
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (06) : 544 - 554
  • [6] Direct analysis of isopropylthioxanthone (ITX) in milk by high-performance liquid chromatography/tandem mass spectrometry
    Bagnati, Renzo
    Bianchi, Giancarlo
    Marangon, Elena
    Zuccato, Ettore
    Fanelli, Roberto
    Davoli, Enrico
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (13) : 1998 - 2002
  • [7] Coupling of high-performance liquid chromatography with Raman spectrometry
    Hong, TDN
    Jouan, M
    Dao, NQ
    Bouraly, M
    Mantisi, F
    JOURNAL OF CHROMATOGRAPHY A, 1996, 743 (02) : 323 - 327
  • [8] Evaluation of the direct injection nebulizer in the coupling of high-performance liquid chromatography to inductively coupled plasma mass spectrometry
    Zoorob, Grace
    Tomlinson, Medha
    Wang, Jian-Shang
    Caruso, Joseph
    1600, Royal Soc of Chemistry, Letchworth, Engl (10):
  • [9] DIRECT COUPLING OF MICRO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FAST ATOM BOMBARDMENT MASS-SPECTROMETRY
    ITO, Y
    TAKEUCHI, T
    ISHII, D
    JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT): : 161 - 166
  • [10] Investigations on the degradation of aspartame using high-performance liquid chromatography/tandem mass spectrometry
    Sun, Jie-Ping
    Han, Qiang
    Zhang, Xiao-Qiong
    Ding, Ming-Yu
    CHINESE CHEMICAL LETTERS, 2014, 25 (09) : 1259 - 1264